Loading...
HomeMy WebLinkAboutReview Checklist� - �.� -� ; . � � TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. Z � Lot � � Zone of Contribution: In Out �eage Commercial: Residential�- Street: ��'� Village: Floor Plan: � #Bedrooms: 2_ Owner: ����� '�i`�,�.1�'lti:Ll�/1�����G�U'Insta.11er: � Address: Phone: Phone: Builder: Engineer: �''/` Address: Phone: � �- Phone: N/A YES NO 1.Required#of co ies received ' 2.Date of soils exa.m and ercolation test not older than 2 ears 3.4-5 ft of naturall occunin ervious material, above water table L,..- 4.Foun+dation 2 ft above hi oint of road H.P.: Fnd: Var.: 5. Water line 10 ft from s tic com onents Var.: �i' 6.Benchmark indica.ted and shown-NGVD if near wetlands 7. S tic tank minimum 10 ft from foundation, deck Var.: c,,/ S.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: (,;,/ ' 9.Leaching minimum 100 ft from wetlands Var.: ° ; 10.Leachin minimum 150 ft from drinkin welU25 ft irri tion well Var.: 11. Tanklleachin minimum 10 ft from ro line Var.: ' 12. S stem meets all other setback r uirements Var.: �� 13. Uses adjustment for maximum high groundwater Var.: 14.Leaching set 4-5 ft above ad'.water or bottom of test hole Var.: �----' 15. System not in to or subsoil(A,B horizons)or 5'removal c._..- 16.Pro sed contours are suitable �_.- 17. S stem meets slo e r irements-min. 1/8", '/a" eferred �.r..� 18. S stem meets breakout r uirements PVC liner: Wall: ��- 19. S �ed tee sizes are ro er, as baffle on outlet tee ; 20. Sewage is under 10,000 for arcel `„/ . 21.No garba. e dis osal ' 22.S stem ade uatel sized for its intended use 23.Minimum 6"stone or com acted below tank and dbox ' ' 24.Ma.nhole covers within 6"of ade, um chamber cover to grade ' 25.Ins ection ort on plastic chambers/leach field ', 26. Electrical ermit for um chamber/S arate meter for du lexes 27.Pump system-2"line,wee hole,check valve,tee in dbox, um size , 28. Septic tank/ um chamber to be factory waterproofed ' 29.Vent rovided if leachin below 3 feet,under driveway/ arkin 30.Buoyanc calculations for tank/ um chamber 31.En ' eer to ins ect and cert' soils: wall: commercial: - 32.Engineer/Re ' ered Sanitarian and Land Surveyor stam s/si ture 33.H-201oadin is sub'ect to vehicular traffic, oundwater 34.Title V A lication and ermit fee, installer si ture 35.Founda.tion footin min. 2 feet above adjusted ound water for new house ��..i ' 36.Deed Restriction r ired max. #bedrooms: maac. flow: d �� 37.Check area lots for oundwater/Label groundwater in Assessor's Ma , Plan reviewed by: l �/'i� ) 6/03/03 ; r �