Loading...
HomeMy WebLinkAboutReview Checklist � -�� _, � ��z�-�,� I TOWN OF YARMOUTH /� � � SEWAGE PLAN REVIEW CHECKLIST Y�,� � ��`�y���'', ; . Location: A.M. /'l� Lot� Zone of Contribution: In�t_ Acreage�� ����� �f Commercial: Residential:�,� Street: � �`� Village: C Floor Plan: #Bedrooms:���7��' Owner: � Insta.11er: s Address: � Phone: - Phone: Builder: Engineer: -����� Address: Phone: Gj �' -� Phone: .. ��'� ' � '! _ � - � r � N/A YES NO l.Required#of copies received ✓ 2.Date of soils exam and ercolation test not older than 2 years (..�-''"' 3.4-5 ft of naturall occurrin ervious material, above water ta.ble �r. 4.Foundation 2 ft above hi oint of road H.P.: Fnd: Var.: 5.Water line 10 ft from s tic components Var.: 6.Benchmark indicated and shown-NGVD if near wetlands 7. S tic tank minimum 10 ft from founda.tion, deck Var.: ��' 8.Leachin minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: 9.Leachin minimum 100 ft from wetlands Var.: v 10.Leaching minimum 150 ft from drinkin welU25 ft irri ation well Var.: --�� 11.Tank/leaching minimum 10 ft from roperry line Var.: � 12. S stem meets all other setback r uirements Var.: L.�' � 13.Uses adjustment for maximum high oundwater Var.: 14.Leaching set 4-5 ft above adj.water or bottom Var.: ��' I5. System not in to or subsoil(A,B horizons) 5'remo 16.Pro osed contours are suitable 17. S stem meets slo e re uirements-min. 1/8", '/4" referred 18. S stem meets breakout re uirements PVC liner: �Wall: v- 19.S ecified tee sizes are proper, gas baffle on outlet tee t� 20. Sewa e is under 10,000 d for parcel ✓ 21.No arba e dis osal �/ - 22. S stem ade uatel sized for its intended use 23.Minimum 6"stone or com acted below tank and dbox � 24.Manhole covers within 6"of grade, um chamber cover to grade t/ 25.Inspection ort on plastic chambers/leach field 26.Electrical ermit for um chamber/S arate meter for du lexes 27.Pump system-2" line,weep hole,check valve,tee in dbox, ump size ��' 28. S tic tank/pum chamber to be factory wat roofed �' 29.Vent provided if lea.ching below 3 feet, under driveway/parking ti� 30.Buoyancy calculations for tank/pum chamber �� 31.En ' eer to ins ect and cert soils: wall: commercial: ✓" 32.En ' eer/Re ' tered Sanitarian and Land Surveyor stam s/si ature 33.H-201oading is sub'ect to vehicular traffic, goundwater 34.Title V A lication and ermit fee, installer si ature �� 35.Foundation footing min. 2 feet above ad'usted ound water for new house 36.Deed Restriction r uired ma�. #bedrooms: � max. flow: Z d 37.Check area lots for groundwater/Label groundwater in Assessor's Ma 1/ Plan reviewed by: �osio3