Loading...
HomeMy WebLinkAboutEngineered Plan - 2016SYSTEM PROFILE PROVIDE MIN. 20" DIAM. WATERTIGHT (NOT TO SCALE) ACCESS COVERS TO WITHIN 6" OF FIN. GRADE ). EL. 11.8' MINIMUM .75' OF COVER OVER PRECAST 1 2% SLOPE REQUIRED OVER SYSTEM NOTE: 2" MIN. WALL PRECAST H-10 THICKNESS REQUIRED 2(T1P.) '0 11.06, 4"OSCH40 PVC 4; PIPES LEVEL 1ST 2' 10" EXISTING 14" TEE SEPTIC TANK TEE \9.66' WATERTEST D'BOX 8.95' o°o°o°o°o°o° FOR LEVELNESS GAS BAFFLE 1°0°°°0010°0 MARK CORNERS OF LEACHING FIELD W/ REBAR SET 4" BELOW GRADE FILTER FABRIC 12' TOP 9.35' 9.14' 8.97' 6" CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 [2]) (—L% % SLOPE) (—!—% SLOPE) FOUNDATION EXIST SEPTIC TANK 52' LEACHING D' BOX 4' FACILITY *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM LEGEND- - 99— EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. —[99]— PROPOSED CONTOUR [98.4] PROPOSED SPOT EL. TH1 Locus or"i" TEST HOLE 2' SLOPE OF GROUND LIVING UTILITY POLE , FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING TEST HOLE LOGS ENGINEER: CRAIG J. FERRARI, SE #13871 WITNESS: AMY VON HONE, RS DATE: 4/13/16 PERC. RATE = < 2 MIN/INCH CLASS ISOILS ELEV. 1 0" 12' A LS 9„ 1OYR 3/2 B LS 28" 1 OYR 5/6 9.7' PERC C 10YR 7/6 G—W ADJ. DATA: p 3.2' WELL: MIW-29 ZONE: A ADJ: 1.1' 120" I I 2' GROUNDWATER ENCOUNTERED 106" INCE #16-101 OHE NOTES VARIANCES REQUESTED UNDER TITLE 5 AND YARMOUTH HEALTH REGULATIONS: 1h: REDUCTION IN GROUNDWATER SEPARATION, 5' TO 4' LASE BENCH MARK — HYDRANT ON FIX TAG BOLT #2038. EL. = 14.9 Scale:1 "= 20' 0 10 20 30 40 50 FEET 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. 6$11 1. DATUM IS ASSUMED PROVIDE INSPECTION PORTS TO 00'If WITHIN 3" OF FINISH GRADE VENT W/ CHARCOAL FILTER 2. MUNICIPAL WATER IS EXISTING 2% SLOPE \ 0 --� \\ Locus or"i" 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. FINISHED GRADE— 4" LOAM & SEED OR PAVE AS REQ. LIVING 4. DESIGN .LOADING FOR ALL PROPOSED PRECAST Cb t o � UNITS TO BE AASHO H—LQ _EAN FILL s � J � 5. PIPE JOINTS TO BE MADE WATERTIGHT. CONNECT AND VENT Nantu ket Uth Sou d S=O.00j -- 06. CONSTRUCTION DETAILS TO BE IN ACCORDANCE ° WITH 310 CMR 15.000 (TITLE 5.) DOUBLE WASHED ° NG FIELD 6"DJE// MIN BELOW INV. 8.8NOT 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND BOTTOM o TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 30.0' 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR 4.0' CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. USE ADJUSTED 10. CONTRACTOR SHALL BE RESPONSIBLE FOR GROUNDWATER ® EL. 4.3 CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. VARIANCES REQUESTED UNDER TITLE 5 AND YARMOUTH HEALTH REGULATIONS: 1h: REDUCTION IN GROUNDWATER SEPARATION, 5' TO 4' LASE BENCH MARK — HYDRANT ON FIX TAG BOLT #2038. EL. = 14.9 Scale:1 "= 20' 0 10 20 30 40 50 FEET 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. 6$11 00 KITCHEN 00'If .y �d too n = 5Y Q, 0 Locus or"i" SFO'p00 LIVING ROOM Cb t o � 'If LOCUS MAP NOT TO SCALE ASSESSORS MAP 42 PARCEL 27 LOCUS IS WITHIN FEMA FLOOD ZONE X (0.2 PCT ANNUAL CHANCE FLOOD HAZARD) AS SHOWN ON COMMUNITY PANEL #25001 CO589J DATED 7/16/2014 SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 3 BEDROOMS @ 110 GPD = 330 GPD USE A 330 GPD DESIGN FLOW FLOOR PLANS SEPTIC TANK: 330 GPD (2) = 660 NOTTO SCALE ** ____-- _ ___ __ ._ ,__ _-- RE—USE—EX!ST4N-G-1000- GAL. _-SSP—TlC-TA.N!z:--- LEACHING: 330 GPD / (.74) = 446 SF REQUIRED 15' X 30' = 450 SF OK 450 SF X .74 = 333 GPD OK USE A 15' X 30' PIPE AND STONE LEACHING FIELD PROP. VENT WITH CHARCOAL FILTER AND BUGSCREEN (FINAL PLACEMENT BY CONTRACTOR WITH HOMEOWNER CONSULTATION) Permit valid for REPAIR OF SEPTIC Sl'Y"I'EM ONLY; due to State and Local septic variances. Board. of Health review and ,approval is required for any. fuNare additions/renovations/alterations to sewage facilities and/or structures/dwelling: Yannouth Fleallh Department OF hf; ��o� DANIELA. OJALA CIVIL No. 465072 GfSTE��` DATE APPROVED k, 1"R a 8 2 0 16 HEALTH DEPT. nE No.409B0 S \ 6A/'404 DANIEL A. OJALA, P.E., P.L.S. , MA DATE BOARD OF HEALTH TITLE 5 SITE PLAIN OF #8 SPRUCE STREET SOUTH YARMOUTH, MA PREPARED FOR ORTOLOTTI CONSTRUCTION I / SANTIAGO DATE: APRIL 20, 2016 off 508-362-4541 I fax 508-362-9880 downcape.com 170Wn M.Pe engineering, Inc. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 .InR Nn.=974.0 Fn.in1 c �d too n = 5Y Q, 0 Locus or"i" our ~ t. Cb t o otr a s � J � P a Shore or. Nantu ket Uth Sou d LOCUS MAP NOT TO SCALE ASSESSORS MAP 42 PARCEL 27 LOCUS IS WITHIN FEMA FLOOD ZONE X (0.2 PCT ANNUAL CHANCE FLOOD HAZARD) AS SHOWN ON COMMUNITY PANEL #25001 CO589J DATED 7/16/2014 SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 3 BEDROOMS @ 110 GPD = 330 GPD USE A 330 GPD DESIGN FLOW FLOOR PLANS SEPTIC TANK: 330 GPD (2) = 660 NOTTO SCALE ** ____-- _ ___ __ ._ ,__ _-- RE—USE—EX!ST4N-G-1000- GAL. _-SSP—TlC-TA.N!z:--- LEACHING: 330 GPD / (.74) = 446 SF REQUIRED 15' X 30' = 450 SF OK 450 SF X .74 = 333 GPD OK USE A 15' X 30' PIPE AND STONE LEACHING FIELD PROP. VENT WITH CHARCOAL FILTER AND BUGSCREEN (FINAL PLACEMENT BY CONTRACTOR WITH HOMEOWNER CONSULTATION) Permit valid for REPAIR OF SEPTIC Sl'Y"I'EM ONLY; due to State and Local septic variances. Board. of Health review and ,approval is required for any. fuNare additions/renovations/alterations to sewage facilities and/or structures/dwelling: Yannouth Fleallh Department OF hf; ��o� DANIELA. OJALA CIVIL No. 465072 GfSTE��` DATE APPROVED k, 1"R a 8 2 0 16 HEALTH DEPT. nE No.409B0 S \ 6A/'404 DANIEL A. OJALA, P.E., P.L.S. , MA DATE BOARD OF HEALTH TITLE 5 SITE PLAIN OF #8 SPRUCE STREET SOUTH YARMOUTH, MA PREPARED FOR ORTOLOTTI CONSTRUCTION I / SANTIAGO DATE: APRIL 20, 2016 off 508-362-4541 I fax 508-362-9880 downcape.com 170Wn M.Pe engineering, Inc. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 .InR Nn.=974.0 Fn.in1