HomeMy WebLinkAboutEngineered Plan - 2017BM @ T.O.F 100.00 ASSUMED 36" (A) 97.0 38" (B) 96.8 4" CLEANOUT (A) PIPE WITH AN 8" INSPECTION 96.0 PORT COVER TO GRADE. SEPTIC SYSTEM PROFILE NOT TO SC ALE COVER TO WITHIN 6" OF FINISHED GRADE 98.0 F.G. 97.0 PIPE TO BE LEVEL 14" TEE AND �I GAS B AFFLE 95.75 1500 GALLON H-10 MONO SEPTIC TANK S =41.1-1' T=30.00 95.55 FOR 2' OUT OF D -BOX 1. 95.38 ID -BOX 6" COMPACT STONE OR COMPACTED B ASE F.G. 98.0 MINIMUM 2" PEASTONE OR GEOTEXTILE FABRIC TOP @ 96.0 0 0 0 0 0 0 0 0 0 0 0 95.18 /10-HIMMINN (2) 500 GAL DRYWELL H-10 WITH 3/4" -1 1/2 OF DOUBLE WASHED STONE 4' ON ENDS AND SIDES 12.5' X 25' BOTTOM OF #1 TEST HOLE _ LOT 13 11,032 SQ. FT. +/- 039 ACRES +/- CID X98.0 WATER SERVICE lU O X98.5 / 11i GAS 20'-o' O T.H. 1 Z T2 T. . 0 X98.4 10'-0' Al �$o /Y$� �9 00 4/ , • r <ISTIN& SELLING I O2 WAY II 8"AL, X98.2 01, CLEANOUTI MAPLE . 1 .,, X98.9 2 CE55POOLS- "` I PUMP OUT AND X99.3 FILL IN. ; X99.2 S 8301 '2111 � 1S1.4S' 5.18' OTTOM @ 93.18 FATH BEDROOM LIVING DINING �. - l4 Arty r � W D GARAGE BEDROOM B ATH B EDROOM KITCHEN 4 SUN LOCUS ROOM EXISTING FLOOR PLAN NOT TO SC ALE i `'1 Scale: 1"=20s s 0 20 40 60 TEST HOLE LOG DATE: 7/5/17 TEST BY: MIKE O'LOUGHLIN WITNESS: AMY VON HONE PERC RATE: < 2 MIN. TEST HOLE # 1 TEST HOLE # 2 0" 98.1 EL 0" 98.0 EL FILL FILL 22" 96.27 EL 12" 97.0 EL C MEDIUM SAND C MEDIUM SAND 2.5Y 6/6 2.5Y 6/6 120" 88.1 EL 120" 88.0 EL NO WATER NO WATER ENCOUNTERED ENCOUNTERED BOTTOM OF PERK 36" PRESOAK 7 MIN. GENERAL NOTES 1. CONTRACTOR TO BE RESPONSIBLE FOR LOCATING ALL UTILITIES, ABOVE & UNDERGROUND, PRIOR TO ANY EXCAVATION OR CONSTRUCTION. 2. SEPTIC SYSTEM IS TO BE INSTALLED IN COMPLIANCE WITH 310 CMR 15.00:TITLE V. 3. THIS PLAN IS NOT TO BE USED FOR PROPERTY. LINE DETERMINATION. 4. DESIGNER TO INSPECT & CERTIFY OVER -DIG, IF REQUIRED BY PLAN, AND FINAL INSPECTION BEFORE BACKFILL. 5. CONTRACTOR TO PROVIDE 48 HOUR NOTICE FOR ANY REQUIRED INSPECTIONS. 6. THIS SYSTEM IS NOT DESIGNED FOR THE USE OF A GARBAGE DISPOSAL. 7. THE TOP OF ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC MARKING TAPE OR A COMPARABLE MEANS IN ORDER TO LOCATE THEM ONCE BURIED. 8. IF SOILS ARE FOUND UNSUITABLE OR DIFFERING FROM THOSE FOUND IN SOIL LOG, CONTACT DESIGNER AND THE BOARD OF HEALTH. 9. IF AN OVERDIG IS REQUIRED OR IF UNSUITABLE SOIL IS FOUND, CLEAN GRANULAR SAND MEETING 310CMR 15.255(3) IS TO BE USED AS FILL MATERIAL, 5' AROUND THE S.A.S. 10. ALL 4" PIPE CONNECTIONS AT SEPTIC TANK AND D -BOX SHALL -BE-MORTARED- IN-F!-LACE--IF--,USING-18'-PLASTIC - __RISER -PIPES, THESE TOO SHALL BE MORTARED IN PLACE. DESIGN DATA DAILY FLOW: (3) BEDROOMS X 110 GPD = 330 GPD SEPTIC TANK: 330 GPD X 2 = 660 GPD USE: 1500 GALLON H-10 MONO SEPTIC TANK DISTRIBUTION BOX: USE: DB -6 H-20 SOIL ABSORPTION SYSTEM: USE: (2) 500 GAL DRYWELLS H-10 WITH DOUBLE WASHED STONE 4' ON ENDS AND 3.87' ON SIDES. SIDEWALL AREA: 75' X 2' X 0.74 = 111 GPD BOTTOM AREA: 12.5' X 25' X 0.74 = 231.25 GPD TOTAL 342.25 GPD TOTAL AREA: 150 SOFT +312.5 SOFT = 462.5 SOFT NOTE 1. PUMPOUT AND FILL IN (2) EXISTING CESSPOOLS. 2. INSTALL (1) 4" (2) WAY CLEANOUT TO GRADE. Yarmouth Redth Deptirtmert ppb 1). ��aarse Date .�`,r. HEALTH AGENT APPROVAL DATE