Loading...
HomeMy WebLinkAboutEngineered Plans - 2017LOCUS DATA CURRENT OWNER BRIAN P. SHEA PLAN REFERENCE LCP 29512-B-1 DEED REFERENCE CTF 141146 ZONING DISTRICT R-25 FLOOD ZONE AE, ELEV. 11 ASSESSORS MAP 17 PARCEL 136-C6 OVERLAY DISTRICT NONE SITE & SEWAGE REPAIR PLAN UNIT 6 184 SO. SEA A VE. IN W. YARMOUTH, MASS DATE: JULY 7, 2017 OWNER/APPLICANT: BRIAN P. SHEA P.O. BOX 1032 W. YARMOUTH, MA 02673 413-262-3113 SHEET 1 OF 3 PREPARED BY: EAS SURVEY, INC. P.O. BOX 1729 SANDWICH, MA 02563 PH. (508) 888-3619 CELL (508) 527-3600 EAS. SU R VEY®YAH 00. COM SLEEPING LOFT AREA ABOVE IS BEDROOM #2 z 3 PKITCHEN p �j DINING UNIT 6 ROOM LIVING 3 ROOM PORCH EXISTING 1,000 GALLON - SEPTIC TANK TO REMAIN. EXISTING LEACHING AREA TO BE CRUSHED AND ABANDONE IN ACCORDANCE WITH TITLE LOT IA BENCHMARK TOP OF CONCRETE FOUNDATION. ELEV. = 7.95 REMOVE EXISTING s 6�• CEDAR — 35 � 0" F l62 68. / PROPOSED LEACHING AREA / 3 ROWS OF 6 QUIK 4'S BED#1 / LOW PROFILE LEACHING / CHAMBERS. 8' / EXISTING / CLEANOUT \ CEDAR \ (TYP) Sou 600. \ \ PROPOSED GALLON PUMP CHAMBER PROPOSED LIMITS OF EXCAVATION TO C-1 HORIZON. 10.5 28 SACT MARSH CANE N LOCUS 4N N7�"Gc LOCUS MAP PROPOSED / NOT TO SCALE: OBSERVATION .� PORT 17-0110 .•T. / ABUTTERS SEPTIC / \ / SYSTEM. INSTALLED IN 2010. 7-- _2929.7' .7' PROPOSED DB -6 EDWAR STONE r Permit valid for REPAIR f)H SE 'It' SYSTEM ONi,Y, due: to State and Local ptic variances. Board. of Ilealth review and avlffov' is required i�ar any ,flu ttire : additionshenovation Alterations to sewage facilities and/or structu7 cs/dN Ring. NIT 7 _ Yifrmouth Health t)cpai snent APPROVE .2. Mame _ Date 0 /A�0W41X20 %A?66?!l GRAPHIC SCALE: 1 INCH = 10 FEET TOP OF FOUNDATION ELEV. 7.95 6.9 EXISTING CLEAN OUT EXISTING JOB # 17-0110 FINISH GRADE ELEV. 6.8 RAISE (1) 24" MH COVER RAISE COVER TO WITHIN TO FINISH GRADE 6" OF FINISH GRADE OELEV. 8.4 FINISH GRADEPUMP ELEV. 7.0 CONTROLS FINISH GRADE ELEV. 8.3 (2) OBSERVATION PORTS TO GRADE / SCREW ON CAP GROUND ELEVATION/8.2 12" OF COVER PROPOSED 40mil POLY LINER ALL AROUND TOP EL.=7.5 BOT. EL.=5.0 x//14 / ` //'/ 2"R47.83 TOP ELEV 7.17 TOP = EX1 5' AROUND SCH 40 4" PVC 5.82 STRIPOUT TO SCH 40 10'0S=0.025 LINER 00 TOP OF "C" INV.= 2 MI-" NAX 4 PVC SCH 40 30' OF 2" 5.27 10"TEE 14"TEE M PER310CMR EXIST. GAS INV.= PVC SCH 40 (24) LOW PROFILE QUIK-4"s INFILTRATORS BAFFLE 5.07 15.255 (C) EXIST. INV.= INV.= 6.77 3 ROWS OF 6 UNITS 4'-1" LIQUID LEVEL INV.= 4.82 INV.= EACH UNIT 34"x48"x8" 0 ADJ. G.W. 4.82 HORIZ. T� 6.50 ELEV. 2.4 5'-4" ALIGNED WITH 24.0 0 ADJ. G.WATER PLUGGED -i ,H EL V3 -'$" OUTLETS (2) 8.5'x24.0' LEACHING AREA 4 EXISTING 1000 GAL H-10 STRIPOUT 18.5' x 34.0' ADJ. G.WATER TH#1 SEPTIC TANK TO REMAIN BOT. 0.49 SITE & SEWAGE REPAIR PLAN UNIT 6 184 50. SEA AVE-. IN W. YARMOUTH, MASS DATE: JULY 7, 2017 OWNER/APPLICANT: BRIAN P. SHEA P.O. BOX 1032 W. YARMOUTH, MA 02673 413-262-3113 SHEET 2 OF 3 PREPARED BY: EAS SURVEY, INC. P.O. BOX 1729 SANDWICH, MA 02563 PH. (508) 888-3619 CELL (508) 527-3600 EAS. SU RVEY@YAH 00. COM DOSING CALCULATIONS: DESIGN FLOW TO CHAMBER REQ'D EMERGENCY STORAGE EMERGENCY STORAGE PROV'D NUMBER OF DOSING CYCLES DEPTH PER CYCLE 0.58' 0.58 x 94.3 DESIGN TDH (3.07'+5.34) DESIGN GPM RUNNING TIME PROPOSED 361 GALLON H-20 PUMP CHAMBER SET ON 6" STONE OR LEVEL STABLE BASE WATERPROOF AT FACTORY (4.0 INSIDE DIAMETER) = 220 GPD SAND FILL = 220 GAL QUICK DISCONNECT = 220 GPD (2.33' x 94.3 G/FT) = 4 PER DAY/TITLE V = 7 INCHES = 55 GAL/DOSE = 8.4 < 12.4 CHART ® 40 GPM = 40 GPM = 55 GAL _ 40 GPM = 83 SEC. ADJ. G.WATER 2" SCH 40 PVC THREADED +/or 1 MIN 23 SEC. PUMP CHAMBER BUOYANCY CALCULATIONS 361 GALLON H-20 5' OUTSIDE DIA. TANK WEIGHT OF TANK= 6080 LBS WEIGHT OF SOIL= 1850 LBS TOTAL WEIGHT= 7930 LBS BUOYANCY FORCE: (1.90 x IIx 4) x 62.4 = 1500 1 LBS 1500 1LBS < 7930 +LBS = 6430 i LBS UPLIFT TANK OIL D D 4{p c�i LA E TY,J . N 211 S'4�V1 AR c C OBSERVATION PORT(S) // SCREW CAP f --2.83'---2.83'-+- 2.83' �---- 8.50 --� SIDE VIEW 24" DIA MIN. MANHOLE COVER BROUGHT TO FINISH GRADE EL 7.0 TOP ELEV. = 5.82 1 -- 6„ 4" PVC uI INV.= 4.82 a.IEMER] 28" 0 ALARM ELEV.= 2.49 OR I PUMP ON EL. = 2.24 6„ PUMP OFF EL. = 1.66 BOT. INS. = 0.99 = 8" BOT. EL = 0.49 0' ? - 0 GREEN TUFF RISER WITH BOLTED COVER OR EQUIVALENT CONCRETE WITH CAST IRON. APPROX. 9" SAND FILL MIN 6" QUICK DISCONNECT 2" PVC DISCHARGE PIPE INV 4.82 0< 1/4" WEEP HOLE f --2.83'---2.83'-+- 2.83' �---- 8.50 --� SIDE VIEW 24" DIA MIN. MANHOLE COVER BROUGHT TO FINISH GRADE EL 7.0 TOP ELEV. = 5.82 1 -- 6„ 4" PVC uI INV.= 4.82 a.IEMER] 28" 0 ALARM ELEV.= 2.49 OR I PUMP ON EL. = 2.24 6„ PUMP OFF EL. = 1.66 BOT. INS. = 0.99 = 8" BOT. EL = 0.49 0' ? - 0 GREEN TUFF RISER WITH BOLTED COVER OR EQUIVALENT CONCRETE WITH CAST IRON. 6" IN. 3/4" TO 1 1/2" STONE 361 GALLON H-20 4"x8"x16" SOLID PRECAST CONCRETE CONCRETE BLOCK PUMP CHAMBER 5' OUTSIDE DIA. / 94 GAL PER FOOT MYERS 0.4 HP SEWAGE PUMP (MODEL SMR) OR EQUIVALENT LOCATE UNDER MH PUMP TO HANDLE MIN, 2" SOLIDS APPROX. 9" COVER QUICK DISCONNECT 2" PVC DISCHARGE PIPE INV 4.82 0< 1/4" WEEP HOLE VALVE MLL-0 M-0CHECK ADJ. G.WATER 2" SCH 40 PVC THREADED w 6 D ELEV. 2.4 PIPE 2 MERCURY FLOAT LEVEL CONTROLS 6" IN. 3/4" TO 1 1/2" STONE 361 GALLON H-20 4"x8"x16" SOLID PRECAST CONCRETE CONCRETE BLOCK PUMP CHAMBER 5' OUTSIDE DIA. / 94 GAL PER FOOT MYERS 0.4 HP SEWAGE PUMP (MODEL SMR) OR EQUIVALENT LOCATE UNDER MH PUMP TO HANDLE MIN, 2" SOLIDS CONSTRUCTION NOTES: 1. CONTRACTORS / INSTALLERS SHALL VERIFY GRADES AND ELEVATIONS AND SITE CONDITIONS PRIOR TO COMMENCING WORK ON THE SITE. 2. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING REGULATIONS. OWNER / APPLICANT IS TO OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY. 3. VEHICULAR TRAFFIC, PARKING OF VEHICLES AND PLACING MATERIALS OVER THE SEPTIC TANK, DISTRIBUTION BOX AND S.A.S. AREA IS PROHIBITED PUMP NOTES 1. POWER CABLES TO BE PLACED IN CONDUIT IN ACCORDANCE WITH LOCAL BUILDING AND WIRE CODES. 2. PUMP AND ALARM TO BE ON SEPERATE ELECTRICAL CIRCUITS. 3. PUMP ALARM TO BE SET AT A CONVENIENT LOCATION ADJACENT TO THE BUILDING AND TO BE BOTH AUDIO AND VISUAL, 4. ELECTRICAL PERMIT REQUIRED JOB # 17-0110 SITE & SEWAGE REPAIR PLAN UNI T 6 184 50. SEA A VE. IN W. YARMOUTH, MASS DATUM: VERTICAL DATUM: NAVD-1988 BENCH MARK USED: TOP OF FOUNDATION BLOCK AT CORNER OF HOUSE ELEVATION 7.95 GENERAL NOTES: 1. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO D.E.P. TITLE V AND THE TOWN OF ;YARMOUTH RULES AND REGULATIONS FOR SUBSURFACE DISPOSAL' OF SEWERAGE. 2. AT LEAST ONE ACCESS POINT OVER TANK TEES SHALL BE ACCESSIBLE WITHIN 3" OF FINISH GRADE, WITH ANY REMAINING ACCESS PORTS BROUGHT TO WITHIN 12" OF FINISH GRADE. 3. ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF WITHSTANDING H-10 LOADING UNLESS OTHERWISE SPECIFIED. 4. THE EXCAVATION CONTRACTOR SHALL VERIFY THE LOCATION OF ALL UTILITIES PRIOR TO ZANY EXCAVATION. 5. ANY MASONRY UNITS USED ITO BRING COVERS TO GRADE OR WITHIN 6" OF GRADE SHALL BE MORTARED IN PLACE. 6. FINISH GRADE SHALL HAVE 'A MINIMUM OF 0.02 FEET PER FOOT OVER THE S.A.S. AND! DISTRIBUTION BOX. 7. SEPTIC TANK SANITARY TEES SHALL BE CONSTRUCTED OF SCHEDULE 40 PVC AND SHALL EXTEND A MINIMUM OF 6" ABOVE THE FLOW LINE AND SHALL IBE ON THE CENTERLINE AND LOCATED DIRECTLY UNDER THE CLEAN OUT MANHOLES. 8. THE INLET PIPE INVERT ELEVATION SHALL BE NO LESS THAN 2 INCHES NOR MORE THAN 3 INCHES ABOVE THE INVERT ELEVATION OF THE OUTLET PIPE. 9. THE SEPTIC TANK SHALL HAVE A MINIMUM COVER OF 9 INCHES 10. THE OUTLET SANITARY TEE' SHALL BE EQUIPPED WITH A GAS BAFFLE, 4 INCHES IN DIAMETER AND CONSTRUCTED OF 4" PVC 11. ALL PIPES SHALL BE SCHEDULE 40 PVC SEWER PIPE AND SHALL BE SLOPED 1/4 INCH PER FOOT MIN. EXCEPT FOR THE FIRST TWO FEET OUT OF THE DISTRIBUTION BOX WHICH SHALL BE LEVEL 12. CHANGES OR REVISIONS TO SEPTIC DESIGN REQUIRE NOTIFICATION TO EAS SURVEY INC. FOR B.O.H. AND DESIGN ENGINEERS REVIEW AND APPROVAL. 13. MAGNETIC TAPE ON ALL COMPONENTS. SYSTEM DESIGN DESIGN FLOW 2 BEDROOMS AT110 GPB/D 22SL GPD REQUIRED SEPTIC TANK _220 x 200% _ = ___440 GAL. SEPTIC TANK PROVIDED EXISTING SEPTIC TANK (TO REMAIN) SIZE OF LEACHING FACILITY REQUIRED DESIGN PERC RATE ____MIN./INCH LONG TERM APPL. RATE_0.74 GPD/S.F. SIZE OF LEACHING SYSTEM PROVIDED: 220 0.74 SF/GPD = -2111-S.F. MIN. REQ. USING 18 QUIK-4 INFILTRATORS CHAMBERS LOW PROFILE UNITS AND NO STONE AROUND 4.73 SF / LF X (3 x 24) = 340 S.F 340 x 0.74 G/SF = 251 GPD 251 GPD PROV > 220 GPD REQ. = 31 GPD RES. NO (GARBAGE DISPOSAL / GRINDER ALLOWED) DATE: JULY 7, 2017 r+tx DTH #1 JZ INDICATESDEEP TEST HOLE D.T.H. #1 A� DATE: 5-31-17 E GROUND ELEV. 6.7 OWNER/APPLICANT: , R. ADJ. GROUNDWATER 2.4 BRIAN P. SHEA 0 1 fs E° INDICATES P-1 28" PERC TEST A P.O. BOX 1032 SANT Ria LOAMY 4�No W. YARMOUTH, MA 02673 �� 52" INDICATES ADJ. GROUNDWATER �, EL.= 6.0 8" 52" OBSERVED GROUNDWATERLOAMY SAND 413-262-3113 7.5YR 5/6 SHEET 3 OF 3EL.= GROUNDWATER ADJUSTMENT TIDAL INFLUENCE 5/31/17 5.2 18° PREPARED BY: EL.= 3.1 C_1 28" EAS SURVEY,INC. VARIANCES REQUESTED B.O.H. ID MEDIUM 5Y 7/6 , OATOR NE, RS CHO EL.= 3.9 34' P.O. BOX 1729 TITLE 5: SOIL EVALUAMY SANDWICH, MA 02563 TO ALLOW THE LEACHING AREA TO BE 4' ABOVE ONE BACKHOETOPERATOR. EL= 2.4 C-22 52" GROUNDWATER IN LIEU OF 5'. A 1' VARIANCE IS REQUESTED. ELLIS BROTHERS C0SAND PH. (508) 888-3619 SOIL TYPE: -j-10YR EL.= 0.2 5/8 78" CELL (508) 527-3600 LOADING RATE? OI74 GAL/SF/MIN EAS. SU RVEY@YAH OO. COM