HomeMy WebLinkAboutEngineered Plan - Rev. 2017(MIN% SLOPE) FOUNDATION- 19' SYSTEM PROFILE ACCESS COVERS TO WITHIN 6" OF FIN. GRADE ALARM AND CONTROL PANEL 1.6' F28'01MINIMUM .75' OF COVER OVER PRECAST TUF-TITE EF -4 EFFLUENT FILTER (OR EQUAL) 1500 GAL H-10 W/MOLDED IN GAS 10" 14" DEFLECTOR TEE SEPTIC TANK TEE 6.25' 1500 GAL. GAS BAFFLE ;; 23 0' PUMP CHAMBER 4' LIQ. LEVEL (ACME OR EQUAL) (SEE DETAIL) 0000000000000000000000000000°0°0°0°000°`O�' o°o°o°o,°,o°o°o°0°0°0°0°0°0°0°0°0°0°000°0 no„o_e_ _n_n_n 000 0 0 0 �n.n_n_n_n_n.o ° % SLOPE WATERPROOF WATERTIGHT ( 8 ) 6" CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 [2]) SEPTIC TANK - 38' *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM ALARM AND CONTROL PANEL TO BE INSTALLED INSIDE BUILDING. ALARM TO BE ON SEPARATE CIRCUIT FROM PUMP INV. IN 23.0' FLOAT SWITCH ALARM ON SETTINGS: PUMP ON 4.4" WORKING RANGE PUMP OFF 1500 GAL. H-10 S 700 GAL.+ RESERVE 8" 4.4 [ 12" T, PUMP CHAMBER PROP. WATERTIGHT COVER TO GRADE PROVIDE QUICK DISCONNECT FOR PUMP NO LOW POINTS 2" PRESSURE LINE -�- SLOPE TO DRAIN BACK TO PC 0.25" WEEP HOLES CHECK VALVE MYERS SRM 4 SUBMERSIBLE 4/10 HP PU4 11 SYSTEM (OR. EQUAL) 000000 0000 0 0 0000 PUMP CHAMBER (NOT TO SCALE) WATERPROOF/WATERTIGHT TEST HOLE LOGS ENGINEER: DANIEL E. GONSALVES. SE #13587 WITNESS: BRUCE MURPHY, RS, CHO DATE: 1/24/2014 PERC. RATE = < 2 MIN/INCH CLASS I SOILS ELEV. 1 D" 29.6' /L/S UNSUIT. 1OYR 3/2 24" 27.6' B /MS UNSUIT. 48" / 1 OYR 6/6 25.6' 100" SILT LOAM 2.5Y 6/3 UNSUIT. 21.3' C2 SIEVE FS 130" 7.5Y 5/8 18.8' C3 SiL UNSUIT. 150" 2.5Y 6/3 17.1' PERCHED H2O AT EL. 25.6' DCE # 13-293 Permit valid for REPAIR OF SF'PTIC SYSTEM ONLY, due- to State and Local scIme variances. Board of health review and approval is required 12ir" any: future additions/ren nations/alterations to sewage facilities and/or strucim-esRhselling: Yarmotith health Department 01 APP110VED a �C I)ate (NOT TO SCALE) ACCESS COVERS TO WITHIN 6" OF FIN. GRADE 27' MINIMUM .75' OF COVER OVER PRECAST PROP. TEE 4"S�SCH40 PVC PIPES LEVEL 1ST 2' NO LOW POINTS 2" PRESSURE LINE n SLOPE TO DRAIN BACK TO PC -E.---�� 'ononooae0000 LOT AREA: 21,098± SF 0.48± AC MAP 1122 PCL 62.2 � r - Z 0 o�\ `,41 eQC; O CPQ Scale: 1 "= 20' 0 10 20 30 40 50 FEET . 1 30.09' 6" CRUSHED STONE OR MECHANICAL COMPACTION. (15:221 [2]) 62' D' BOX ` 29.88' , 29.92' 0.28' WATERTEST D'BOX FOR LEVELNESS 40 QUICK4 STANDARD LP INFILTRATOR UNITS EACH UNIT: 4' X 2.83 X 8" HIGH OVERALL DIMENSIONS TO OUTSIDE OF UNITS: 11.3' X 40' (NO STONE PROPOSED) ( 1 % SLOPE) ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. PROVIDE INSPECTION PORTS TO ZZWITHIN 3" OF FINISH GRADE -o CVCTCl/ 31.0' ,I-' ,I- ,I. 91 i LEACHING FACILITY 30.27' 29.6' 4.0' PERCHED H2O FOUND TH 1 EL. 25.6' PROP. VENT WITHCHARCOAL FILTER AND BUGSCREEN (FINAL PLACEMENT BY CONTRACTOR WITH HOMEOWNER CONSULTATION) ALT. TO SLOPE: PROVIDE 1' H GH LANDSCAPE TIE RETAINING WAL TO 97 CONTAIN FILL T.W. EL. 3 .5' PROVIDE 107' 0 40 MIL LINER AT 4' OFF SAS IN AREA SHOWN. TOP AT 2'91/ ELEV. 30.3', BOTTOM AT EL. 28.3'± PROVIDE 1' LANDSCAPE TIEH BY 27' / Q P RETAINING WALL TO G� CONTAIN FILL T.W. EL. 30.0' - CAUTION: GASLINE T( -L-Ifn DATE 4' REMOVAL OF UNSUITABLE SOIL REQUIRED - AROUND PERIMETER OF LEACHING FACILITY, DOWN TO SUITABLE SOIL LAYER. REPLACE WITH CLEAN MED. SAND. TO MEET SPECIFICATIONS OF 310 CMR 15.255(3) DANIEL A. OJALA, P. E., P.L.S. APPROVED Tho e e Rood Locus r Rfe 6A s Q� r'. c � a Sand ie �� I LOCUS MAP NOT TO SCALE SCALE 1"=2000'± ASSESSORS MAP 122 PARCEL 62 VARIANCES REQUESTED UNDER TITLE 5: 14.405 1a: REDUCTION IN SETBACK, SAS TO LOT LINE (10' TO 5'); 1b: SAS TO FNDN. (20' TO 13'); 1h: REDUCTION IN SETBACK TO G -W (5' TO 4') 15.255 (5): REDUCTION IN REMOVAL OF UNSUITABLE SOIL (5' TO 4'); 15.415 (2): REDUCTION IN 4' OF CONTIGUOUS SUITABLE SOIL BELOW SAS (4' TO 2.5') SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 5 BEDROOMS 0 110 GPD = 550 GPD USE A 550 GPD DESIGN FLOW SEPTIC TANK: 550 GPD (2) = 1100 USE (1) 1500 GAL. H-10 SEPTIC TANK USE (1) 1500 GAL. H-10 PUMP CHAMBER LEACHING: 4.72 SF/LF x 4'.. LENGTH = 18.88 SF PER STANDARD QUICK' 4 INFILTRATORS IN FIELD CONFIGURATION 550 GPD/0.74 GPD/SF = 743.2 SF LEACHING REQ'D 743.2 SF/18.88 SF/UNIT = 39.4 UNITS THEREFORE, USE GRAVELLESS SYSTEM OF 40 QUICK4 STANDARD LP UNITS IN FIELD CONFIGURATION OF 4 ROWS OF 10 UNITS 558.8 GPD PROVIDED DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF 260 ROUTE 6A YARMOUTH PORT PREPARED FOR MASS. NEW CHURCH UNION. DATE: JAN. 29, 2014 REV. 3/24/14 (HEALTH DEPT. COMMENTS) REV. 4/29/14 (PER BOH APPROVAL) REV. 8/24/17 (INV.'S, ASBLT TANK) off 508-362-4541 fax 508-362-9880 downcope.com down cape engineering, inc. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 MA NOTES 1. DATUM IS APPROX. NM 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED 'PRECAST UNITS TO BE AASHO H -1Q S. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT UNE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. J�G 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AHD PERMISSION OBTAINED FROM BOARD OF HEA `; 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING AND �QP\�G VERIFYING -THE LOCATION OF ALL UN(1-888-344 DERGROUND & Q 6 OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF Q� �C 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. I 12. EXISTING LEACHING FACILITY SHALL BE PUMPED 't AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. 13. ELECTRICAL PERMIT REQUIRED 14. INSTALLER TO CONFIRM SUITABILITY OF ELECTRICAL SYSTEM FOR PUMP INSTALLATION PROP. VENT WITHCHARCOAL FILTER AND BUGSCREEN (FINAL PLACEMENT BY CONTRACTOR WITH HOMEOWNER CONSULTATION) ALT. TO SLOPE: PROVIDE 1' H GH LANDSCAPE TIE RETAINING WAL TO 97 CONTAIN FILL T.W. EL. 3 .5' PROVIDE 107' 0 40 MIL LINER AT 4' OFF SAS IN AREA SHOWN. TOP AT 2'91/ ELEV. 30.3', BOTTOM AT EL. 28.3'± PROVIDE 1' LANDSCAPE TIEH BY 27' / Q P RETAINING WALL TO G� CONTAIN FILL T.W. EL. 30.0' - CAUTION: GASLINE T( -L-Ifn DATE 4' REMOVAL OF UNSUITABLE SOIL REQUIRED - AROUND PERIMETER OF LEACHING FACILITY, DOWN TO SUITABLE SOIL LAYER. REPLACE WITH CLEAN MED. SAND. TO MEET SPECIFICATIONS OF 310 CMR 15.255(3) DANIEL A. OJALA, P. E., P.L.S. APPROVED Tho e e Rood Locus r Rfe 6A s Q� r'. c � a Sand ie �� I LOCUS MAP NOT TO SCALE SCALE 1"=2000'± ASSESSORS MAP 122 PARCEL 62 VARIANCES REQUESTED UNDER TITLE 5: 14.405 1a: REDUCTION IN SETBACK, SAS TO LOT LINE (10' TO 5'); 1b: SAS TO FNDN. (20' TO 13'); 1h: REDUCTION IN SETBACK TO G -W (5' TO 4') 15.255 (5): REDUCTION IN REMOVAL OF UNSUITABLE SOIL (5' TO 4'); 15.415 (2): REDUCTION IN 4' OF CONTIGUOUS SUITABLE SOIL BELOW SAS (4' TO 2.5') SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 5 BEDROOMS 0 110 GPD = 550 GPD USE A 550 GPD DESIGN FLOW SEPTIC TANK: 550 GPD (2) = 1100 USE (1) 1500 GAL. H-10 SEPTIC TANK USE (1) 1500 GAL. H-10 PUMP CHAMBER LEACHING: 4.72 SF/LF x 4'.. LENGTH = 18.88 SF PER STANDARD QUICK' 4 INFILTRATORS IN FIELD CONFIGURATION 550 GPD/0.74 GPD/SF = 743.2 SF LEACHING REQ'D 743.2 SF/18.88 SF/UNIT = 39.4 UNITS THEREFORE, USE GRAVELLESS SYSTEM OF 40 QUICK4 STANDARD LP UNITS IN FIELD CONFIGURATION OF 4 ROWS OF 10 UNITS 558.8 GPD PROVIDED DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF 260 ROUTE 6A YARMOUTH PORT PREPARED FOR MASS. NEW CHURCH UNION. DATE: JAN. 29, 2014 REV. 3/24/14 (HEALTH DEPT. COMMENTS) REV. 4/29/14 (PER BOH APPROVAL) REV. 8/24/17 (INV.'S, ASBLT TANK) off 508-362-4541 fax 508-362-9880 downcope.com down cape engineering, inc. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 MA