Loading...
HomeMy WebLinkAboutBLD-18-000722I 4 SCHEDULE 40 PVC MIN. SLOPE 1tFINISHED GRADE OVER CHAMBERS 9.4 �.10.3i TOP OF FOUNDATION 11.50� FINISH GRADE OVER D -BOX 10.3 t E "� I S PROVIDE EXTENSION RISER FINISH GRADE OVER TANKEL.= SLOPE @ 2% MIN. 1. UNLESS OTHERWISE NOTED A FINISHED GRADE WITH COVER OVER INLET & , REMOVABLE WATER TIGHT COVER OVER INSPECTION PORT WITH ACCESS BOX TO O ERWISE ALL SYSTEM COMPONENTS AND CONSTRUCTION @ FOUNDATION =9.5'± OUTLET TO WITHIN 6 OF F.G. 10.5± METHODS SHALL BE IN ACCORDANCE WITH TITLE 5 OF THE STATE ENVIRONMENTAL RISER TO WITHIN 6 OF FINISHED GRADE WITHIN 370F F.G. (SEE PLAN) 5 DIA. OUTLET(S) { M _ '^ _ CODE AND ANY APPLICABLE LOCAL RULES. 20" MIN. ACCESS9"MIN. (2. ANY CHANGES TO THIS PLAN MUST BE APPROVED BY THE BOARD OF HEALTH AND THE PROP. 4"SCH. 44 COVER (3 TYP.) 367MAX. PROVIDE EQUALIZERS ° DESIGN ENGINEER. PVC SEWER PIPE 9" MIN. ON EACH OUTLET (IYP.) " N. { PROP. 4" SCH. 40 36" MAX. S 36" MIAX.. TOP OF SAS / B.O. _ $,41' 3. 4" SCHEDULE 40 PVC PIPE WITH WATER TIGHT JOINTS SHALL BE USED IN DISPOSAL E L = 23'± PVC SEWER PIPE SYSTEM UNLESS OTHERWISE NOTED. „ 2" DROP MIN. „ I MIN. SLOPE@ ,% 6" 3 n 9. TO PREVENT BREAKOUT, THE PROPOSED FINISHED GRADE SHALL NOT BE LESS THAN i 3 DROP MAX. 3 MIN.SIOPE@ 1% L - Al4 t PROVIDE WATERTIGHT ELEVATION = 8.41' FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE SAS. UNLESS A JOINTS TYP,40 MIL GEOMEMBRANE LINER IS PLACE AT LEAST FIVE FEET FROM S.A.S. AND THE TOP OF ' 13" N 4" PVC IN FROM .> -� { 38' � Q 13" , t 5.85 14 SEPTIC TANK 4 PVC OUT TO (T P.), ,? THE LINER IS NOT LESS THAN THE BREAKOUT ELEVATION. # 8.30 LEACHING FACILITY .0.59 7.13 (TYP) 5.` SLOPE ALL SOLID PIPE AT 1.0% MINIMUM. 8.55 12" 6" 6. THIS SYSTEM IS NOT DESIGNED FOR A GARBAGE DISPOSAL I „ 8.22' 1 7 92'- 7.33' laid flat 2.875' (34.5")--� 48 OUTLET TEE MIN. 8.05 (-TYP.) GAS BAFFLE 5.0' F 7. LOCAL BOARD OF HEALTH AND DESIGN ENGINEER TO BE NOTIFIED PRIOR TO BACK 6" CRUSHED STONE (-1-yp) 5' MIN. FILLING WHEN SYSTEM IS NEARLY COMPLETE AND READY FOR INSPECTION. SYSTEM IS I OVER MECHANICALLY 14.38' 1 REQ'D NOT TO BE BACK FILLED WITHOUT FIRST OBTAINING APPROVAL FROM BOARD OF HEALTH 23.4' TO FOUNDATION COMPACTED BASE 30.0' AND DESIGN ENGINEER. 5 OUTLET DISTRIBUTION BOX +! 8. ELEVATIONS BASED ON NAVD 88 DATUM. BENCHMARK ELEVATION OF 8.68 ESTABLISHED ON 6" CRUSHED STONE TO BE INSTALLED ON A LEVEL STABLE E OVER MECHANICALLY BASE.- FIRST TWO FEET OF OUTLET. GROUND WATER ELEV.= 2.33 A NAIL IN A UTILITY POLE AS SHOWN ON PLAN. COMPACTED BASE LAID L bt 9. CONTRACTOR SHALL VERIFY ALL UTILITY LOCATIONS PRIOR TO CONSTRUCTION _ SEPTIC K PIPES TO BE LEVEL. � �I-IL�ER (PROFILE) CH�1��IBE� {Ei`,�C) VIE'�`V� , PROPOSED 1,500 GALLON CONCRETES P IC TAN i I i=THROUGH DIG -SAFE AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE AT ' ' '_ " '_ " Dimensions erW in (BY INFILTRATOR SY T� .,S, I, t 1 -888 -DIG -SAFE AND ANY OTHER APPLICABLEAGENCIES. REPORT AN D LENGTH 10-6 WIDTH 5 8 DEPTH �8 t p � CROSS SECTION VIEW P casset MA _..,. I AG Y DISCREPANCIES .-� , - , Precast Corp., o )- TO THE DESIGN ENGINEER. `q P {(/ ��. }[� 4I qj � _ j#7 0 g \B30_1`<. _ i ,� � _ j(- . R t }+y} jj% ro , ) 4�„*y�j { j(� ��j i y J i...... � \./ � 1 .p: � � � � � � „�.�.- �:..� 2 �. �;..:+ 'T -.,.. 1 .. .. . � ...- - .. ! } £ `8. R...iR i,�i 'l�' ! i 4f � �s l.� d � � . a � d #w' &w� i 3 � - � D) { 10, ALL JOINTS WHERE PIPE ENTERS AND EXITS CONC. STRUCTURES SHALL BE MADE WATERTIGHT. NOT TO SCALE NOT TO SCALE NOT TO SCALE i f • v !a {{ „�.� „� ,._,_ -.�- { 11. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING IES ) I ,� I ,�- � REGULATIONS. OWNER/APPLICANT IS TO OBTAIN SUCH DETERMINATION FROM PROPOSED APPROPRIATE AUTHORITY. 1,500 Q MAP 33 1,�0o GALLON - "� � � � : � .. • i � Q% . B LOT 369 SEPTIC TANK INSPECTOR: Amy Vonhone 12. ALL SEPTIC SYSTEM COMPONENTS SHALL WITHSTAND H-10 LOADING UNLESS LOCATED � i- rJ !<- , ' r fi • # { UNDER MORE THAN 3 FEET OF COVER OR LOCATED UNDER PAVEMENT, DRIVES, OR PROPOSED 1G" Or;�, Y` , ,.--- lu M- •w EVALUATOR: John L. Churchill, PE, CSE i 7I" ry 4", / 1 / I '. ' TRAVELED WAYS IN WHICH CASE THEY SHALL WITHSTAND H-20 LOADING. DISTRIBUTION •f .. , , r t f � . � � �, .� V....� C.S.E. APPROVAL DATE: Nov. 1997 � BOX - - -`--" T 13. DOUBLE WASHED CRUSHED STONE SHALL BE FREE OF ALL DIRT DUST AND FINES. I t DAT a 7, 2017. , E: .Jun E 9x3 ° � , , S85 24 " TEST PIT #. 1 14. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL LOAM SUBSOIL AND UNSUITABLE c p 9x2 J% �� -- -- = `- _ 1 .---- I _ MATERIAL IN AREA BENEATH AND FOR 5 FT. ON ALL SIDES OF LEACHING FACILITY. 103.70 , - �, _ t! r ELEV TOP - 9.0 REPLACE ALL UNSUITABLE MATERIAL WITH N ARSE SAND FREE FROM Y l _ O , L CLEAN CO E O CLAY, PROPOSED Benchmark = 2.33' FINES OR OTHER UNSUITABLE MATERIAL IN ACCORDANCE WITH 310 CMR 15.255(3). 10.2' g o 1 ELEV WATER INSPECTION PART fri TP 1 �- c Elev. In 8. tti - ( _ t 15. CONTRACTOR SHALL NOTIFY DESIGN ENGINEER OF ANY DISCREPANCIES FOUND IN .- ` � � OA.� � Elev. - 8.68 � -- \�' /' t : • PERC RATE - ,- L._it- SITE CONDITIONS FROM THOSE SHOWN PRIOR TO CONTINUATION OF WORK. -, NAVD 88 � �` � � PROPOSED TOTAL (30) 9x0 I : ARC 36 LEACHING - 9x2 co / _ DEPTH OF PERC = 15. LLr. .'- ' !I 16. PROPOSED PROJECT IS LOCATED WITHIN: 9x1 , - 1 � � " �, � ,� .. c CHAMBERS IN A FIELD t- 1t \ \ \ { .- - ASSESSORS MAP. 33 PARCEL. 369.21L :_ T--._ -�..; a � � '~i TEXTURAL CLASS. 1 ! ..�. � CONFIGURATION .� �--. .� J LC)CUS .�.----� ' S� o,.� Loup Ae I ', ti OWNER OF RECORD. _ e a S µI(1Y� n 0 ,RES -� + .-�' �.. �� � 1 REMOVE AND REPLACE ml_..' _a C, -� /1 I 1'� i J° UNSUITABLE MATERIAL TO _ � Fol A .1 i I* ! �\ "Coo SOILS WITH CLEAN n 30.0 \ / - ,,..--•--"' COARSE SAND r,4I r -' { 6 y • E LU MAP 33 $ _- ao - N T n l :- CR - ) 'ive-in t _ r "--- s 30 ( LOT 367 V c 8 / I 1 I r 3 I / 30.0' . } seater s , z t i y 801, 10.5 ( 28' us � � M �Cj w \ 1 i 92„ LOCUS PLAN �)- co SCALE: 1" = 1000' i 0,.I i 120" Loamy Sand 10Yr 3/2 Loamy Sand 10Yr 516 Fine -Medium Sand 2.5Y 7/4 I' o tlin Q 80" 2.5Yr 5/8 - Standin 92" -1.00' I I - E G 50x0 EXISTING SPOT GRADE ! e-�- _,. { _�_ PROPOSED t qty r..,ti2'`c.a=h,:,S r ,=ti,:.�.�F.i� � . I \: I 50 EXISTING CONTOUR I MAP 33 -a DWELLING 11,51 ? T , . ; 50 PROPOSED SPOT GRADE LOT 368 TO = 11.5' I u� ( I _J Ir s : SLAG 9.0' �� � e I _ = NUMBER OF BEDROOMS (DESIGN) 4 INSPECTOR: Amy Vonhone 50 PROPOSED CONTOUR I DESIGN FLOW 110 GAUDAY/BEDROOM --& 1 EVALUATOR: John L. Churchill, PE, CSE C.S.E. APPROVAL DATE: Nov. 1997 . Uvinra r PROPOSED OVERHEAD UTILITIES { & Gr;!. TOTAL DESIGN FLOW 440 GALIDAY i 1 G" Cil ! W \ i• ' DESIGN FLOW x 200 %o = 880 GAL/DAY! DATE: June 7, 2017 V V PROPOSED WATER LINE ,. l _ ' i t ` t l TEST PIT #: 2 -. r i4.. + USE PROPOSED 1,500 GALLON SEPTIC TANK j tuELEV TOP = 9.20 TEST PIT LOCATION i 39.2' 28 ELEV WATER = 2.20' ` .----, J g � PROPOSED 1,50 GALLON SEPTIC TANK 10" C.",!.--. C' PERC RATE _ < 2 minlinch -36.2 TMBERS (SAS effect edea leaching area 431 sf > 4 0 sf mi required - SEE NOTE 2 BELOW) DEPTH OF PERC = 32"-50" PROPOSED 4" SOLID SCHEDULE 40 PVC PIPE r MAP 33 / / w # z i r .w. / I I � Q PROPOSED DISTRIBUTION BOX i• - SYSTEM CAPACITY I! TEXTURAL CLASS: 1 o 12,662* S.F. ,_ /A.LOT 369.2 / ) S (TOTAL L.F. OF CHAMBERS) (4.8 SFILF) (0.74 GPD/SQ.FT.) = GPD PROPOSED ARC 36 LEACHING CHAMBER { O w € (150') (4.8 SF/LF) (0.74 GAUSQ.FT.) = 532.8 GAL. LEACHING / DAY I A LLJ 8 !TOTALS: � " TOTAL NUMBER OF CHAMBERS: ' 30 / ( _ TOTAL NUMBER OF COUPLINGS: 0 ! B 1 ZONING SETBACKS _ j 1 TOTAL LEACHING AREA: 720.0 SQ -FT. i I C, /7 - i 3 F,:E 1 j TOTAL LEACHING CAPACITY: 532.8 GAL./DAY „ C) b ! 30 . / c , o ` / 32" oa ° / l Perc Z \ { 50„ NOTES: r / ! N88° 3T 10"W g6 11.) EFFECTIVE LEACHING AREA OF 4.80 SFIL.F OBTAINED FROM THE - I C f DEPARTMENT OF ENVIRONMENTAL PROTECTION APPROVAL LETTER r 89.63 CERTIFICATION FOR GENERAL USE ISSUED TO INFILTRATOR WATER TECHNOLOGIES, LLC., DATE OF REVISION: FEBRUARY 19, 2015, „ MODIFIED JUNE 12,2015; TRANSMITTAL NUMBER = X264258. NOTES: 2.) SAS DESIGNED IN ACCORDANCE WITH STANDARD CONDITIONS FOR 94., `ALTERNATIVE SOIL ABSORPTION SYSTEMS WITH GENERAL USE ? / 12,. €�Ir!"� s CERTIFICATION AND/OR APPROVED FOR REMEDIAL USE { \ , y Y� �� / \ t 1.) MAGNETIC MARKING TAPE SHALL BE PLACED ALONG THE TOP EDGE i C" F'l, !�i, 24 PI',:n 1 1 ? (REVISED: MARCH 20, 2015). \ f OF EACH SEPTIC SYSTEM COMPONENT. { I 120" Loamy Sand 10Yr 312 Loamy Sand 10Yr 516 Fine -Medium Sand 2.5Y 7/4 Mottling84" 2.5Yr 518 Standing94" SZ # Yarmouth Health Department WORK MUST CONFORM TO AL 8.53' PP12 ED TOWN BYL S & REGULATIONS r ` YARMOUTH WATER DEPT DATE +tame Date i 6.70 1 7131/17 - SJI JLC ADD PROPOSED WATER LINE & MOVE DECK 6.53' ' REV DATE BY APP'D. DESCRIPTION 5.03' AA._ PROPOSED SITE PLAN LZN OF t � cti PREPARED FOR: °'ILLAR SARAJON REALTY LLC CtiUR C ILL JR. +� 2.20' " LOCATED ATED AT i 59 MELGO LANE I t 1.37' S. YARMOUTH,MA 02664 SCALE: 1 INCH = 10 FT. DATE: JUNE 23, 2017 /` -� : xAt`' ,. �: j►. - -0.80 0 5 10 20 40 FEET '� ` MOF �V - 2.) CONTRACTOR SHALL VERIFY SOIL CONDITIONS IN THE LOCATION OF ��t c Esq I i - � Y � .. _ f�= .. THE PROPOSED LEACHING FACILITY TO ENSURE CONSISTENCY WITH T I;LE= t.3, , Jam° l PREPARED BY: TEST PIT DATA SHOWN ON THIS PLAN. REPORT TO ENGINEER AND LOCAL 3 RESERVED FOR BOARD OF HEALTH USE # U .++rc, s JC ENGINEERING INC. -- - STENT WITH TEST PIT DATA. ! { ' BOARD OF HEALTH 1F SOILS ARE NOT CONST I � � �� .r�L� o 2854 CRANBERRY HIGHWAY _-- g` ` MELGO LANE 3.) CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ANY AND ALL Fs t J CO (� UTILITIES (WHETHER SHOWN OR NOT SHOWN ON THIS PLAN) TO THE ' s, �s EAST WAREHAM, MA 02538 (PRIVATE WAY) SITE PLA 1 V PROPOSED DWELLING AND OBTAIN ALL APPLICABLE PERMITS. 508.273.0377 SCALE: V= 10' E i i `� Drawn By: SJI } Designed By: SJI Checked By: JLC JOB No 3823 ADDRESS: 5 FOUNTAIN STREET 8.50' MILFORD, MA 01757 1 I FEMA FLOOD ZONE AE(EL.11) 6.50' I COMMUNITY PANEL # 1 2501 C0589J (dated 7-16-2014) 17. DEED REFERENCE: BOOK 1283, PAGE 259 4 y 18. PLAN REFERENCE: PLAN BOOK 110, PAGE 53 I ZONING DISTRICT: R-25 ZONING REQUIREMENTS PROPOSED I MIN. FRONT YARD = 30' 36.2' MIN. SIDE YARD =15' 35.7' 2.33' MIN. REAR YARD = 20' 39.2' MAX. LOT COV. (by stnictures) = 25% 9% I MAX. LOT COV. (by structures/paving) = 40% 14% 1.33' MAX. BUILDING HEIGHT = 35' < 35' -1.00' I I - E G 50x0 EXISTING SPOT GRADE ! e-�- _,. { _�_ PROPOSED t qty r..,ti2'`c.a=h,:,S r ,=ti,:.�.�F.i� � . I \: I 50 EXISTING CONTOUR I MAP 33 -a DWELLING 11,51 ? T , . ; 50 PROPOSED SPOT GRADE LOT 368 TO = 11.5' I u� ( I _J Ir s : SLAG 9.0' �� � e I _ = NUMBER OF BEDROOMS (DESIGN) 4 INSPECTOR: Amy Vonhone 50 PROPOSED CONTOUR I DESIGN FLOW 110 GAUDAY/BEDROOM --& 1 EVALUATOR: John L. Churchill, PE, CSE C.S.E. APPROVAL DATE: Nov. 1997 . Uvinra r PROPOSED OVERHEAD UTILITIES { & Gr;!. TOTAL DESIGN FLOW 440 GALIDAY i 1 G" Cil ! W \ i• ' DESIGN FLOW x 200 %o = 880 GAL/DAY! DATE: June 7, 2017 V V PROPOSED WATER LINE ,. l _ ' i t ` t l TEST PIT #: 2 -. r i4.. + USE PROPOSED 1,500 GALLON SEPTIC TANK j tuELEV TOP = 9.20 TEST PIT LOCATION i 39.2' 28 ELEV WATER = 2.20' ` .----, J g � PROPOSED 1,50 GALLON SEPTIC TANK 10" C.",!.--. C' PERC RATE _ < 2 minlinch -36.2 TMBERS (SAS effect edea leaching area 431 sf > 4 0 sf mi required - SEE NOTE 2 BELOW) DEPTH OF PERC = 32"-50" PROPOSED 4" SOLID SCHEDULE 40 PVC PIPE r MAP 33 / / w # z i r .w. / I I � Q PROPOSED DISTRIBUTION BOX i• - SYSTEM CAPACITY I! TEXTURAL CLASS: 1 o 12,662* S.F. ,_ /A.LOT 369.2 / ) S (TOTAL L.F. OF CHAMBERS) (4.8 SFILF) (0.74 GPD/SQ.FT.) = GPD PROPOSED ARC 36 LEACHING CHAMBER { O w € (150') (4.8 SF/LF) (0.74 GAUSQ.FT.) = 532.8 GAL. LEACHING / DAY I A LLJ 8 !TOTALS: � " TOTAL NUMBER OF CHAMBERS: ' 30 / ( _ TOTAL NUMBER OF COUPLINGS: 0 ! B 1 ZONING SETBACKS _ j 1 TOTAL LEACHING AREA: 720.0 SQ -FT. i I C, /7 - i 3 F,:E 1 j TOTAL LEACHING CAPACITY: 532.8 GAL./DAY „ C) b ! 30 . / c , o ` / 32" oa ° / l Perc Z \ { 50„ NOTES: r / ! N88° 3T 10"W g6 11.) EFFECTIVE LEACHING AREA OF 4.80 SFIL.F OBTAINED FROM THE - I C f DEPARTMENT OF ENVIRONMENTAL PROTECTION APPROVAL LETTER r 89.63 CERTIFICATION FOR GENERAL USE ISSUED TO INFILTRATOR WATER TECHNOLOGIES, LLC., DATE OF REVISION: FEBRUARY 19, 2015, „ MODIFIED JUNE 12,2015; TRANSMITTAL NUMBER = X264258. NOTES: 2.) SAS DESIGNED IN ACCORDANCE WITH STANDARD CONDITIONS FOR 94., `ALTERNATIVE SOIL ABSORPTION SYSTEMS WITH GENERAL USE ? / 12,. €�Ir!"� s CERTIFICATION AND/OR APPROVED FOR REMEDIAL USE { \ , y Y� �� / \ t 1.) MAGNETIC MARKING TAPE SHALL BE PLACED ALONG THE TOP EDGE i C" F'l, !�i, 24 PI',:n 1 1 ? (REVISED: MARCH 20, 2015). \ f OF EACH SEPTIC SYSTEM COMPONENT. { I 120" Loamy Sand 10Yr 312 Loamy Sand 10Yr 516 Fine -Medium Sand 2.5Y 7/4 Mottling84" 2.5Yr 518 Standing94" SZ # Yarmouth Health Department WORK MUST CONFORM TO AL 8.53' PP12 ED TOWN BYL S & REGULATIONS r ` YARMOUTH WATER DEPT DATE +tame Date i 6.70 1 7131/17 - SJI JLC ADD PROPOSED WATER LINE & MOVE DECK 6.53' ' REV DATE BY APP'D. DESCRIPTION 5.03' AA._ PROPOSED SITE PLAN LZN OF t � cti PREPARED FOR: °'ILLAR SARAJON REALTY LLC CtiUR C ILL JR. +� 2.20' " LOCATED ATED AT i 59 MELGO LANE I t 1.37' S. YARMOUTH,MA 02664 SCALE: 1 INCH = 10 FT. DATE: JUNE 23, 2017 /` -� : xAt`' ,. �: j►. - -0.80 0 5 10 20 40 FEET '� ` MOF �V - 2.) CONTRACTOR SHALL VERIFY SOIL CONDITIONS IN THE LOCATION OF ��t c Esq I i - � Y � .. _ f�= .. THE PROPOSED LEACHING FACILITY TO ENSURE CONSISTENCY WITH T I;LE= t.3, , Jam° l PREPARED BY: TEST PIT DATA SHOWN ON THIS PLAN. REPORT TO ENGINEER AND LOCAL 3 RESERVED FOR BOARD OF HEALTH USE # U .++rc, s JC ENGINEERING INC. -- - STENT WITH TEST PIT DATA. ! { ' BOARD OF HEALTH 1F SOILS ARE NOT CONST I � � �� .r�L� o 2854 CRANBERRY HIGHWAY _-- g` ` MELGO LANE 3.) CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ANY AND ALL Fs t J CO (� UTILITIES (WHETHER SHOWN OR NOT SHOWN ON THIS PLAN) TO THE ' s, �s EAST WAREHAM, MA 02538 (PRIVATE WAY) SITE PLA 1 V PROPOSED DWELLING AND OBTAIN ALL APPLICABLE PERMITS. 508.273.0377 SCALE: V= 10' E i i `� Drawn By: SJI } Designed By: SJI Checked By: JLC JOB No 3823 TOP OF FOUNDATION = 11.50' PROVIDE EXTENSION RISER FINISH GRADE OVER TANK EL.= & FINISHED GRADE WITH COVER OVER INLET , @ FOUNDATION =9.5'± OUTLET TO WITHIN 6" OF F.G. T_ 10.5'± 20" MIN. ACCESS 9"MIN. p PROP. 4" SCH. 40 COVER (3 TYP.) 36"MAX. PVC SEWER PIPE -A PROP. 4" SCH. 40 + PVC SEWER PIPE L = 23 t 2" DROP MIN. F MIN SLOPE n 1% 6" 3" to3n ga I, 4SCHEDULE 40 PVC MIN. SLOPE 1% FINISH GRADE OVER D -BOX 10.3+t FINISHED GRADE OVER CHAMBERS= 9.4'- 10,3' G NIERA _ NOTES' SLOPE @ 2% MIN. REMOVABLE WATER TIGHT COVER OVER 1, UNLESS OTHERWISE NOTED, ALL SYSTEM COMPONENTS AND CONSTRUCTION RISER TO WITHIN 6" OF FINISHED GRADE j INSPECTION PORT WITH ACCESS BOX TO METHODS SHALL BE IN ACCORDANCE WITH O TITLE 5 F THE STATE ENVIRONMENTAL LAN) T NT L 3 OF F.G. (SEEP 5 WITHIN DIA. OUTLET(S) CODE AND ANY APPLICABLE LOCAL RULES. 2. ANY CHANGES TO THIS PLAN MUST BE APPROVED BY THE BOARD OF HEALTH AND THE i PROVIDE EQUALIZERS DESIGN ENGINEER. 9"MIN. ON EACH OUTLET (TYP.) 9� MIN. 3. 4" SCHEDULE 40 PVC PIPE WITH WATER TIGHT JOINTS SHALL BE USED IN DISPOSAL 36' MAX. 36 MAX. TOP OF SAS ! B.O. = 8.4 , SYSTEM UNLESS OTHERWISE NOTED. - i 4 4. TO PREVENT BREAKOUT, THE PROPOSED FINISHED GRADE SHALL NOT BE LESS THAN 3 DROP MAX. N. SLOPE 196 -' 4 ± PROVIDE WATERTIGHT ELEVATION = 8.41' FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE SAS. UNLESS A /- 13" 4" PVC IN FROM r'' JOINTS P. 1. 8' Q 13" 40 MIL GEOMEMBRANE LINER IS PLACE AT LEAST FIVE FEET FROM S.A.S. AND THE TOP OF 8.85 14" + SEPTIC TANK 4" PVC OUT TO (TYP.) ,? THE LINER IS NOT LESS THAN THE BREAKOUT ELEVATION. 8.30 LEACHING FACILITY 0,59' 7.13 (TYP) q , f 5. SLOPE ALL SOLID PIPE AT 1.0% MINIMUM. I 8.55' + 12" 6" + „ l 6. THIS SYSTEM IS NOT DESIGNED FOR A GARBAGE DISPOSAL. " OUTLET TEE 8.22 MIN. 8.05 i 7.92 7.33 (laid flat) 2.875 (34.5 )� I 48 5.01 (�'P•) 7. LOCAL BOARD OF HEALTH AND DESIGN ENGINEER TO BE NOTIFIED PRIOR TO BACK GAS BAFFLE 6" CRUSHED STONE ;FILLING WHEN SYSTEM IS NEARLY COMPLETE AND READY FOR INSPECTION. SYSTEM IS i OVER MECHANICALLY (TYP.) 5' MtN. 14.38' f ; REQ'0 NOT TO BE BACK FILLED WITHOUT FIRST OBTAINING APPROVAL FROM BOARD OF HEALTH I 23.4' TO FOUNDATION I COMPACTED BASE ' 30.0' 5 AND DESIGN ENGINEER. OUTLET DISTRIBUTION BOX 6" CRUSHED STONE I 8. ELEVATIONS BASED ON NAVD 88 DATUM. BENCHMARK ELEVATION OF 8.68 ESTABLISHED ON I TO BE INSTALLED ON A LEVEL STABLE OVER MECHANICALLY l BASE. FIRST TWO FEET OF OUTLET GROUND WATER ELEV.= 2.33 i A NAIL IN A UTILITY POLE AS SHOWN ON PLAN. COMPACTED BASE ,r I I- i 9. CONTRACTOR SHALL VERIFY ALL UTILITY LOCATIONS PRIOR TO CONSTRUCTION 1 500 GALLON CONCRETE SEPTIC TANK PIPES TO BE LAID LEVEL. CHAMBERS (PROFILE) CI ArxlI��RS (END VIEW) PROPOSED r � INC)HROUGH DIG -SAFE AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE AT + (Dimensions per Wiggin (BY INFILTRATOR, SY TEV/ , NC LENGTH 0 -6 WIDTH 5 -8 DEPTH 5 -8 CROSS SECTION VIEW ! 1 -888 -DIG -SAFE AND ANY OTHER APPLICABLE AGENCIES. REPORT ANY DISCREPANCIES _, . .�. Precast Corp., Pocasset, MA) . �. !^a g ,� I . ¢-, " TO THE DESIGN ENGINEER. C , S t 1 I t a 4 6 s 8a ;, 5�J i s i 1 i i x i +I ,,e a ., _�s.�...., I `+ i ANUI I t ! -" ` ' "�" ` " ' ' `i `"' g 10• ALL JOINTS WHERE PIPE ENTERS AND EXITS CONC. STRUCTURES SHALL BE MADE WATERTIGHT. .,. ,_� , rt I �.. NOT TO SCALE NOT TO SCALE ; NOT TO SCALE �t M. _._ , 11. NO DETERMINATION HAS BEEN MADEAS TO COMPLIANCE WITH DEEDED OR ZONING `-SI D, REGULATIONS. OWNER/APPLICANT IS TO OBTAIN SUCH DETERMINATION FROM PROPOSED i >. _` 0� ,.._- . .. I 1 MAP 33 1 500 GALLON{'"'i i"' r _.; Q/I } t i 0 g i APPROPRIATE AUTHORITY. , / LOT 369 SEPTIC TANK "- jJ • r�1' !� _ t v • �. INSPECTOR: Amy Vonhone 12. ALL SEPTIC SYSTEM COMPONENTS SHALL WITHSTAND H-10 LOADING UNLESS LOCATED ' DA,KA > ) �`� , .� . I UNDER MORE THAN 3 FEET OF COVER OR LOCATED UNDER PAVEMENT, DRIVES, OR a EVALUATOR, John L. Churchill, PE CSE i ( PROPOSED � " 0'.1 ,r : - e, � f t l ! 3 j ' TRAVELED WAYS IN WHICH CASE THEY SHALL WITHSTAND H-20 LOADING. TRIr-L,� i' , .S. E. APPROVAL DATE: I 1 DISTRIBUTION � r < , -- ,�-�� ,�,__� � r,/ , •,tn ,�: ��..._. ,- �% � .� ' _�.�.►%. C Nov. 1997 I - BOX . ; ;'M '` , .1 T' I / , %� '� 13. DOUBLE WASHED CRUSHED STONE SHALL BE FREE OF ALL DIRT, DUST AND FINES. y \ } June 7, 2017 x3,..f' �`�9x2' DATE. i t a Y S85° 24'20"E, w , •;`- -' y TEST PIT#: 1 14. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL LOAM, SUBSOIL AND UNSUITABLE -.( `fir L 9x2' MATERIAL IN AREA BENEATH AND FOR 5 F'1". ON ALL SIDES OF LEACHING FACILITY. 0 103.70' ELEV TOP = 9.00' p REPLACE ALL UNSUITABLE MATERIAL WITH CLEAN COARSE SAND FREE FROM CLAY, PROPOSED % :: j ( Benchmark I y,a -."'` . ! I a�' ELEV WATER = 2.33' FINES OR OTHER UNSUITABLE MATERIAL IN ACCORDANCE WITH 310 CMR 15.255(3). 10.2' o -- INSPECTION PORT �-- r-9 0 ` Nail in UP TP 1 " r- Elev. = 8.68' "�°"' . �,, f'"` �-- i PERC RATE _ 15. CONTRACTOR SHALL NOTIFY DESIGN ENGINEER OF ANY DISCREPANCIES FOUND IN � � � NAVD 88 � �� �- -- � ----- ; SITE CONDITIONS FROM THOSE SHOWN PRIOR TO CONTINUATION OF WORK. L. I PROPOSED TOTAL (30) 9x0-•.---.�„_„ = Cn DEPTH OF PERC = g r ,n11 ---- - 16. PROPOSED PROJECT IS LOCATED WITHIN, 1 ARC 36 LEACHING 9x1' t a - i 15.1' U ; 6 ti i �Qv CHAMBERS IN A FIELD 'a \ \ C7 "'' -'�i I j TEXTURAL CLASS: 1 ASSESSOR'S MAP: 33 PARCEL: 369.2 i �- --� _ I CONFIGURATION \ ` �,. \, J R n. n_ - ' ✓�� LOCUS �----= i I \ \\ } I o ,•-'- , i OWNER OF RECORD: ESTATE OF LOUIS A. BONVINO '"�- RESERVE I � �'' �.� .- � •�--,,,-- :� I , REMOVE AND REPLACE 1 / '$ / on o 0, q" , UNSUITABLE MATERIAL TO 1 I I I`. "C'SOILS WITH CLEAN , l ."� r "-' " i 30.0 � � � I Ll � \'�-_.�..,•-.�-r � 6 \. COARSE SAND r '�,----."" Q ,. \ ... r- '.. O s! � ...8' - / � '` . a �, Cry' (-" + i0 B MAP 33 D o t \ v I ; I 30" I LOT 367 o �9- / I .I e - n 't --- I ea to r o -co � `� y � t,J + C15 IC 10" PINIE ,-, 10.5' I i \ vo 2U to oc LOCUS PLAN s 1 1 W IA#r j ; O "-K� \ -`....'- W,! -----•--- � � SCALE: 1" =1000' 120„ Loamy Sand 10Yr 3/2 Loamy Sand 10Yr 5/6 Fine -Medium Sand 2.5Y 7/4 Mottling 80" U 2.5Yr 5/8 Standing a 92" #`57 , I ? 50x0' EXISTING SPOT GRADE i. PROPOSED I I L..} I "_ 1 t. .aw 6-- �-_ a I 1 i'vim c f it'. C.), I.`'' ..i;>";..} -t.. _.,.� - I �_..} 1ES.,.d' 1', i � `' � E3 I D 4 d t , y I 1 MAP 33-BEDRCOr,4 I � � 50 -- EXISTING CONTOUR _ E- ° DV'JELLING Clw / I 50 PROPOSED SPOT GRADE LOT 368 t TOF = 11,5'± 1 J I ; INSPECTOR: Amy Vonhone / SLAB = c,,0 �. + I / �� / ,fl ;NUMBER OF BEDROOMS (DESIGN) 4 i � r� 7 PROPOSED CONTOUR , w j l R EVALUATOR: John L. Churchill, PE, CSE I -��- DESIGN FLOW 110 GAL/DAY/BEDROOM 1997 I TOTAL DESIGN FLOW 440 GAL/DAY ; C.S.E. APPROVAL DATE: Nov. I D/o'0" PROPOSED OVERHEAD UTILITIES • r „; 11" OA- - E June 7, 2017 i ( 41 O�:,r� p I ,- �4 Y E � I � � ;DESIGN FLOW x 200 %' 880 GAL/DAY I DATE: � V! V� PROPOSED WATER LINE � _ / ' D'- �r I c ! TEST PIT #: 2 Y . I USE PROPOSED 1,500 GALLON SEPTIC TANK i a ELEV TOP = 9.20' i TEST PIT LOCATION 39.2' ' `-�. 28 I } ELEV WATER = 2.20' PROPOSED 1,500 GALLON SEPTIC TANK r .1 3 PERC RATE _ < 2 minlinc10001 h } O 36.2' INSTALL 30 -ARC 36 LEACHING CHAMBERS - " PROPOSED 4" SOLID SCHEDULE 40 PVC PIPE _ _ W (SAS effective leaching area 431 sf > 400 sf min. required - SEE NOTE 2 BELOW) $ DEPTH OF PERC 32%50" MAP 33 I / A'` Z TEXTURAL CLASS: 1 CI PROPOSED DISTRIBUTION BOX LOT 369.2 / >0. SYSTEM CAPACITY I (TOTAL L.F. OF CHAMBERS) (4.8 SF/LF) (0.74 GPDISQ.FT.) = GPD j I PROPOSED ARC 36 LEACHING CHAMBER {.. O a4rr, 12,6621 S.F. / I O w (150') (4.8 SF/LF) (0.74 GAL/SQ.FT.) = 532.8 GAL. LEACHING /DAY Cn p 0" o,50, / I A I / a TOTALS: $„ TOTAL NUMBER OF CHAMBERS: 30 i ZONING SETBACKS TOTAL NUMBER OF COUPLINGS: 0 B _ ! �/ TOTAL LEACHING AREA: 720.0 SQ.FT. ,7 PINIIE:I l TOTAL LEACHING CAPACITY: 532.8 GAL./DAY 30" 32„ 0 0 t C� °ca / � ,� � Perc o �/ I I 50" Z loll.� \ l NOTES: 1.) EFFECTIVE LEACHING AREA OF 4.80 SFILF OBTAINED FROM THE C N880 37'10"Wt DEPARTMENT OF ENVIRONMENTAL PROTECTION APPROVAL LETTER 89.63' CERTIFICATION FOR GENERAL USE ISSUED TO INFILTRATOR WATER / 3.. P l;:! E TECHNOLOGIES, LLC:, DATE OF REVISION: FEBRUARY 19, 2015, I 64' MODIFIED JUNE 12,2015; TRANSMITTAL NUMBER - X264258. ;I 1 ' 2.) SAS DESIGNED IN ACCORDANCE WITH STANDARD CONDITIONS FOR 94„ .NOTES: ALTERNATIVE SOIL ABSORPTION SYSTEMS WITH GENERAL USE / 2" P;N E CERTIFICATION AND/OR APPROVED FOR REMEDIAL USE 1.) MAGNETIC MARKING TAPE SHALL BE PLACED ALONG THE TOP EDGE � i 24" P1'.- f 1 (REVISED: MARCH 20, 2015). 3 OF EACH SEPTIC SYSTEM COMPONENT. ! 120„ Loamy Sand 10Yr 3/2 Loamy Sand 10Yr 516 Fine -Medium Sand 2.5Y 7/4 Mottling a 84" 2.5Yr 5/8 _ Standing ft 94" 8.53' 2 8/11/17 SJI JLC ADD STOOP & SHORTEN DRIVEWAY 6.70' € 1 7/31/17 SJI JLC ADD PROPOSED WATER LINE & MOVE DECK 6.53' ? REV. DATE BY APP'D. DESCRIPTION " 5.03' ? PROPOSED SITE PLAN .-,HOF PREPARED FOR: o JOHN r` c ! CHURCHI JR. �^ SARAJON REALTY LLC o CML 2.20, I " NO.,tt LOCATED AT , .. 1 57 MELGO LANE 1.37' v S. YARMOUTH, MA 02664 / SCALE: 1 INCH = 10 FT. DATE: JUNE 23, 2017 . i -0.80' I L►�W 0 5 10 20 40 FEET VERIFY SOIL CONDITIONS IN THE LOCATION OF t1 ,� i,J�,ham--- �i J '`-' �` /--' •- 2.) CONTRACTOR SHALL VE TREE/ THE PROPOSED LEACHING FACILITY TO ENSURE CONSISTENCY WITH - _ a �_ 4 r _ PREPARED BY: ` LIC -- TEST PIT DATA SHOWN ON THIS PLAN. REPORT TO ENGINEER AND LOCAL !Al. "�• JC ENGINEERING, INC. - - - - r - - - - RESERVED FOR BOARD OF HEALTH USE ; BOARD OF HEALTH IF SOILS ARE NOT CONSISTENT WITH TEST PIT DATA. JR - •8_ f _ _ afi:,r 2854 CRANBERRY HIGHWAY 1 ` MELGO LANE 3.) CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ANY AND ALL r ss isr /- EAST WAREHAM, MA 02538 (PRIVATE WAY) SITE PLAN UTILITIES (WHETHER SHOWN OR NOT SHOWN ON THIS PLAN) TO THE ° 'o PROPOSED DWELLING AND OBTAIN ALL APPLICABLE PERMITS. I j I ► I 508.273.0377 SCALE: 1" = 10' } V Drawn By- SJI Designed By SJI s Checked By: JLC JOB No. 3823 ADDRESS: 5 FOUNTAIN STREET 8.50' , MILFORD, MA 01757 " FEMA FLOOD ZONE AE(EL.11) COMMUNITY PANEL # 25001 CO589J (dated 7-16-2014 ) 6.50' � 17, DEED REFERENCE: BOOK 1283, PAGE 259 18. PLAN REFERENCE:. PLAN BOOK 110, PAGE 53 ZONING DISTRICT: R-25 ` ZONING REQUIREMENTS PROPOSED ( MIN. FRONT YARD = 30 MIN. SIDE YARD =15' 36.2 35.7' 2.33' MIN. REAR YARD = 20' 39.2' MAX. LOT COV. (by structures) = 25% 9% 10 � 1, MAX. LOT COV. (by structures/paving) = 40% 14% 1.33' ( MAX. BUILDING HEIGHT= 35' < 35' L.. E a,� - � A ?ny #`57 , I ? 50x0' EXISTING SPOT GRADE i. PROPOSED I I L..} I "_ 1 t. .aw 6-- �-_ a I 1 i'vim c f it'. C.), I.`'' ..i;>";..} -t.. _.,.� - I �_..} 1ES.,.d' 1', i � `' � E3 I D 4 d t , y I 1 MAP 33-BEDRCOr,4 I � � 50 -- EXISTING CONTOUR _ E- ° DV'JELLING Clw / I 50 PROPOSED SPOT GRADE LOT 368 t TOF = 11,5'± 1 J I ; INSPECTOR: Amy Vonhone / SLAB = c,,0 �. + I / �� / ,fl ;NUMBER OF BEDROOMS (DESIGN) 4 i � r� 7 PROPOSED CONTOUR , w j l R EVALUATOR: John L. Churchill, PE, CSE I -��- DESIGN FLOW 110 GAL/DAY/BEDROOM 1997 I TOTAL DESIGN FLOW 440 GAL/DAY ; C.S.E. APPROVAL DATE: Nov. I D/o'0" PROPOSED OVERHEAD UTILITIES • r „; 11" OA- - E June 7, 2017 i ( 41 O�:,r� p I ,- �4 Y E � I � � ;DESIGN FLOW x 200 %' 880 GAL/DAY I DATE: � V! V� PROPOSED WATER LINE � _ / ' D'- �r I c ! TEST PIT #: 2 Y . I USE PROPOSED 1,500 GALLON SEPTIC TANK i a ELEV TOP = 9.20' i TEST PIT LOCATION 39.2' ' `-�. 28 I } ELEV WATER = 2.20' PROPOSED 1,500 GALLON SEPTIC TANK r .1 3 PERC RATE _ < 2 minlinc10001 h } O 36.2' INSTALL 30 -ARC 36 LEACHING CHAMBERS - " PROPOSED 4" SOLID SCHEDULE 40 PVC PIPE _ _ W (SAS effective leaching area 431 sf > 400 sf min. required - SEE NOTE 2 BELOW) $ DEPTH OF PERC 32%50" MAP 33 I / A'` Z TEXTURAL CLASS: 1 CI PROPOSED DISTRIBUTION BOX LOT 369.2 / >0. SYSTEM CAPACITY I (TOTAL L.F. OF CHAMBERS) (4.8 SF/LF) (0.74 GPDISQ.FT.) = GPD j I PROPOSED ARC 36 LEACHING CHAMBER {.. O a4rr, 12,6621 S.F. / I O w (150') (4.8 SF/LF) (0.74 GAL/SQ.FT.) = 532.8 GAL. LEACHING /DAY Cn p 0" o,50, / I A I / a TOTALS: $„ TOTAL NUMBER OF CHAMBERS: 30 i ZONING SETBACKS TOTAL NUMBER OF COUPLINGS: 0 B _ ! �/ TOTAL LEACHING AREA: 720.0 SQ.FT. ,7 PINIIE:I l TOTAL LEACHING CAPACITY: 532.8 GAL./DAY 30" 32„ 0 0 t C� °ca / � ,� � Perc o �/ I I 50" Z loll.� \ l NOTES: 1.) EFFECTIVE LEACHING AREA OF 4.80 SFILF OBTAINED FROM THE C N880 37'10"Wt DEPARTMENT OF ENVIRONMENTAL PROTECTION APPROVAL LETTER 89.63' CERTIFICATION FOR GENERAL USE ISSUED TO INFILTRATOR WATER / 3.. P l;:! E TECHNOLOGIES, LLC:, DATE OF REVISION: FEBRUARY 19, 2015, I 64' MODIFIED JUNE 12,2015; TRANSMITTAL NUMBER - X264258. ;I 1 ' 2.) SAS DESIGNED IN ACCORDANCE WITH STANDARD CONDITIONS FOR 94„ .NOTES: ALTERNATIVE SOIL ABSORPTION SYSTEMS WITH GENERAL USE / 2" P;N E CERTIFICATION AND/OR APPROVED FOR REMEDIAL USE 1.) MAGNETIC MARKING TAPE SHALL BE PLACED ALONG THE TOP EDGE � i 24" P1'.- f 1 (REVISED: MARCH 20, 2015). 3 OF EACH SEPTIC SYSTEM COMPONENT. ! 120„ Loamy Sand 10Yr 3/2 Loamy Sand 10Yr 516 Fine -Medium Sand 2.5Y 7/4 Mottling a 84" 2.5Yr 5/8 _ Standing ft 94" 8.53' 2 8/11/17 SJI JLC ADD STOOP & SHORTEN DRIVEWAY 6.70' € 1 7/31/17 SJI JLC ADD PROPOSED WATER LINE & MOVE DECK 6.53' ? REV. DATE BY APP'D. DESCRIPTION " 5.03' ? PROPOSED SITE PLAN .-,HOF PREPARED FOR: o JOHN r` c ! CHURCHI JR. �^ SARAJON REALTY LLC o CML 2.20, I " NO.,tt LOCATED AT , .. 1 57 MELGO LANE 1.37' v S. YARMOUTH, MA 02664 / SCALE: 1 INCH = 10 FT. DATE: JUNE 23, 2017 . i -0.80' I L►�W 0 5 10 20 40 FEET VERIFY SOIL CONDITIONS IN THE LOCATION OF t1 ,� i,J�,ham--- �i J '`-' �` /--' •- 2.) CONTRACTOR SHALL VE TREE/ THE PROPOSED LEACHING FACILITY TO ENSURE CONSISTENCY WITH - _ a �_ 4 r _ PREPARED BY: ` LIC -- TEST PIT DATA SHOWN ON THIS PLAN. REPORT TO ENGINEER AND LOCAL !Al. "�• JC ENGINEERING, INC. - - - - r - - - - RESERVED FOR BOARD OF HEALTH USE ; BOARD OF HEALTH IF SOILS ARE NOT CONSISTENT WITH TEST PIT DATA. JR - •8_ f _ _ afi:,r 2854 CRANBERRY HIGHWAY 1 ` MELGO LANE 3.) CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ANY AND ALL r ss isr /- EAST WAREHAM, MA 02538 (PRIVATE WAY) SITE PLAN UTILITIES (WHETHER SHOWN OR NOT SHOWN ON THIS PLAN) TO THE ° 'o PROPOSED DWELLING AND OBTAIN ALL APPLICABLE PERMITS. I j I ► I 508.273.0377 SCALE: 1" = 10' } V Drawn By- SJI Designed By SJI s Checked By: JLC JOB No. 3823 ftp P s3 a" , If " f0,600 p1r VV 20 �� ---- 10 o; o p sty 6 c5 9290 11, 400 t �' o 2 c Cm o C 0 7 SS �03•1 a:Y 9046- t C) W QQ 2 -- Qp5 2. 760a 14. � 4. ae Ar Sha Z3a,8 Z°� S J 060, 0 r } 113 ass 9 00 8 9/6 � \ 10, 930 o Anqus �, �, 585.2 20 3 ed Mme, 106.1. i �°y F r Int _ o x'20 w SPS'°ne rn 5 85 2 7 —'"9 10 Cp 10 .100 N 85 , o' 00 9212/01 450 t _ N f 09.9 cedar m 30.00 o N _ 50 0 2. 1 _ �r g cedar U r 2 Stake . 2,00 = .,:►- _, C. ��er S p F� U8 D / V/ S/ ON OF L 4 IUD ' �th`'r� 11,622 � A L.C. I � y50UTH YAPMOUTHO PROPERTY or _CJORHA Alf OrT "T 9C-7 bnch/Lay `%¢ C -vi / / 9S3 q n ers Cr=NTERVI LLE, i I� (Typ) �I i BOTTOM FOOTING ELEVATION 4.83' FRONT ELEVATION SCALE 1/4'=1P -0,f NAIL 6" EDGE NAILING, 12'* FIELD NAILING BOTTOM PLATE TO FRAME (16d) 0 3/FT. TOP SPLICE LENGTH = 6' 20 (16d) NAILS EACH SIDE OF SPLICE CONTINUOUS RIDGE VENT I I f I (TYP) I I I I I( I! CONTRCTOR SHALL I ! I I I MAINTAIN 48" MINIMUM FROST PROTECTION (TYP.) 12" SONOTUSE (TYP.) �/ U E�IN OTTOM FOOTING ELEVATION = 4.83'_- - ' � �... L_ ._ _ ._ _.._ J _ _ _ - I - _ - -- _ _ 24" BIGFOOT SONOTUBE (TYP.) REAR ELEVATION SCALE: 1/4"=1,_0" NAIL REO. 6" EDGE NAILING, 12" FIELD NAILING BOTTOM PLATE. TO FRAME (16d) @ 3/FT: TOP SPLICE LENCTH = 6' 20 (16d) NAILS EACH SIDE OF SPLICE I` FIRST FLOOR _PLAN SCALE: 1/4'1=1'-O" FIRST FLOOR AREA: 1008 S.F. 4'--6- EXISTING FOUNDATION ENCLOSURE. 1008 S.F. REQUIRED AMOUNT OF FLOOD VENTS: 1008 S.F. / 200 S.F. PER VENT = 6 NINTS INSTALL 6 SMART VENTS AT NO MORE THAN 12" ABOVE GRADE IN LOCATIONS SHOWN ON THIS SHEET: GENERAL NOTES: 1. DWELLING IS LOCATED WITH FLOOD ZONE AE(EL. 11). 2. THE CONSTRUCTION OF THE FOUNDATION TO BE IN ACCORDANCE WITH SECTION 322—FLOOD RESISTANT CONSTRUCTION OF THE EIGHTH EDITION OF MASSACHUSETTS STATE BUILDING CODE. 3. BOTTOM OF FOOTINGS TO HAVE ADEQUATE FROST PROTECTION. REFER TO SITEPLAN FOR FINISH GRADES ,AROUND FOUNDATION, . SEE THIS SHEET FOR SMART VENT DETAILS AND REQUIRED OPENINGS IN WALL. 5. BOTTOM OF SMART VENTS TO BE INSTALLED NO MORE THAN 12" ABOVE. FINISH GRADE. 6. THERE SHALL BE 1 SQUARE INCH OF FREE VENT OPENING FOR EVERY 1 SQ. FT. OF FLOOR AREA. EACH SMART VENT IS CERTIFIED FOR 200 SQUARE FEET OF ENCLOSED FLOOR AREA. 7. SMART VENTS AVAILABLE FROM A.H. HARRIS & SONS, INC., 3131 CRANBERRY HIGHWAY, EAST WAREHAM, MA 02538, (508) 783--9990. 8. REFER TO ARCHITECTURAL PLANS PREPARED BY WOODTEX, HIMROD, NEW YORK, PREPARED FOR MARCELLA HOLBROOK, DATED OCTOBER 27, 2016 FOR REMAINING BUILDING LAYOUT AND DETAILS. 9. EXTERIOR SHEATHING ON KNEE -WALLS SHALL BE NAILED WITH Bd COMMON 'NAILS AT 6" O.C. EDGE SPACING AND 12" O.C. FIELD SPACING, FOUNDATION NOTES: 1. FOUNDATION DESIGN BASED' ON THE FOLLOWING PRESUMED SOIL BEARING CAPACITTrS CRYSTALLINE BEDROCK -- 12,000 'PSF SEDIMENTARY ROCK - 4,000 'PSF SANDY GRAVEL OR GRAVEL = 3,000 PSF SAND, SILTY SAND, CLAYEY SAND, SILTY GRAVEL AND CLAYEY GRAVEL — '2,000 PSF CLAY, SANDY CLAY, SILTY CLAY, AND CLAYEY SILT - 1,500 PSF 2. CONCRETE SHALL REACH A COMPRESSIVE STRENGTH OF (PSI) IN THE FOLLOWING LOCATIONS. BASEMENT WALLS, FOUNDATION WALLS, EXTERIOR WALLS AND OTHER VERTICAL CONCRETE WORK' EXPOSED TO THE WEATHER -- 3,000 PSI -GARAGE FLOORS - 3,500 PSI 3. THE GENERAL CC;NTRACTOR SHALL VERIFY ALL L?iMENSIONS ANY DISCREPANCIES " INCONSISTENCIES OR AMBIGUITIES SHALL BE REPORTED TO JCE PRIOR TO PROCEEDING WITH THE WORK. _ 4.' THE SILL PLATE OR FLOOR SYSTEM SHALL BE ANCHORED TO THE FOUNDATION WITH 5/8" 0 BOLTS PLACED 42" O.C. WITH 3"x3"xY¢" PLATE WASHERS AND V-12" INCHES FROM END AND CORNERS. BOLTS SHALL EXTEND A MINIMUM OF 15 INCHES INTO MASONRY OR SEVEN INCHES INTO CONCRETE. 5. A PERIMETER SEAL SHALL BE PROVIDED UNDER 2x6 PRESSURE TREATED SILL, 6. FOUNDATION WALLS SHALL EXTEND AT LEAST EIGHT INCHES ABOVE THE FINISHED GRADE ADJACENT TO THE FOUNDATION AT ALL POINTS. EXCEPTION: WHERE MASONRY VENEER IS USED, FOUNDATION WALLS `SHALT_. EXTEND A MINIMUM OF FOUR INCHES ABOVE THE FINISHED GRACE. 7. STEEL REINFORCEMENT SHALL CONFORM TO A.S.T.M. 615. GRACIE 60. jsA OF SMOKE DETECTOR LOCATION oma'' JOH 4 g CHURCNiit..i1R. (�( CARBON MONOXIDE DETECTOR LOCAMON o 1. .4160 2442 2442 2442: 2442 2442 �` is � UD HEAT DETECTOR LOCATION 7t-4» T 2" 6'-3" 4`-60 21'-8 " le-340,PROPOSED DWEEUING FOR: SARAJON REALTY LLC SCALE. 1 14"=10-0,r ' APPROVED BY: DRAVYN BY: S� l 36'-0" ! DATE: 7/31/17 REVISED: 8/11/17 SECOND FL0OR P L A fel ENGINEERING, PREPARED BY: SCALE: 1/4"=l' -O" JC E N IN E E R I N , I N C. _SECOND FLOOR AREA: 1008 S.F. 57 MELGO LANE DRAWNG NUMBER: YARMOUTH, MA B 2'-3"_i LINEN co m ( m o � uo m Q m o f 0 f BATH04 BEDROOM #3 to ( IN N CLOSET f .- o n!i ( `iLINEN 6� M 11'-6 I ATTIC[d SD STAIRCASE 6_01 o 5'-6" I I L ----I N = ....._ .._ .,._ —. 3-2x16. . ,o LINEN - tV t � 2 - 2x10 ABOVE 2 - 200 ABOVE N r CHASE DOWN N 21-10" 1 G'j h BEDROOM #4 .� BEDROOM #2 N 210016" U.C. t EXISTING FOUNDATION ENCLOSURE. 1008 S.F. REQUIRED AMOUNT OF FLOOD VENTS: 1008 S.F. / 200 S.F. PER VENT = 6 NINTS INSTALL 6 SMART VENTS AT NO MORE THAN 12" ABOVE GRADE IN LOCATIONS SHOWN ON THIS SHEET: GENERAL NOTES: 1. DWELLING IS LOCATED WITH FLOOD ZONE AE(EL. 11). 2. THE CONSTRUCTION OF THE FOUNDATION TO BE IN ACCORDANCE WITH SECTION 322—FLOOD RESISTANT CONSTRUCTION OF THE EIGHTH EDITION OF MASSACHUSETTS STATE BUILDING CODE. 3. BOTTOM OF FOOTINGS TO HAVE ADEQUATE FROST PROTECTION. REFER TO SITEPLAN FOR FINISH GRADES ,AROUND FOUNDATION, . SEE THIS SHEET FOR SMART VENT DETAILS AND REQUIRED OPENINGS IN WALL. 5. BOTTOM OF SMART VENTS TO BE INSTALLED NO MORE THAN 12" ABOVE. FINISH GRADE. 6. THERE SHALL BE 1 SQUARE INCH OF FREE VENT OPENING FOR EVERY 1 SQ. FT. OF FLOOR AREA. EACH SMART VENT IS CERTIFIED FOR 200 SQUARE FEET OF ENCLOSED FLOOR AREA. 7. SMART VENTS AVAILABLE FROM A.H. HARRIS & SONS, INC., 3131 CRANBERRY HIGHWAY, EAST WAREHAM, MA 02538, (508) 783--9990. 8. REFER TO ARCHITECTURAL PLANS PREPARED BY WOODTEX, HIMROD, NEW YORK, PREPARED FOR MARCELLA HOLBROOK, DATED OCTOBER 27, 2016 FOR REMAINING BUILDING LAYOUT AND DETAILS. 9. EXTERIOR SHEATHING ON KNEE -WALLS SHALL BE NAILED WITH Bd COMMON 'NAILS AT 6" O.C. EDGE SPACING AND 12" O.C. FIELD SPACING, FOUNDATION NOTES: 1. FOUNDATION DESIGN BASED' ON THE FOLLOWING PRESUMED SOIL BEARING CAPACITTrS CRYSTALLINE BEDROCK -- 12,000 'PSF SEDIMENTARY ROCK - 4,000 'PSF SANDY GRAVEL OR GRAVEL = 3,000 PSF SAND, SILTY SAND, CLAYEY SAND, SILTY GRAVEL AND CLAYEY GRAVEL — '2,000 PSF CLAY, SANDY CLAY, SILTY CLAY, AND CLAYEY SILT - 1,500 PSF 2. CONCRETE SHALL REACH A COMPRESSIVE STRENGTH OF (PSI) IN THE FOLLOWING LOCATIONS. BASEMENT WALLS, FOUNDATION WALLS, EXTERIOR WALLS AND OTHER VERTICAL CONCRETE WORK' EXPOSED TO THE WEATHER -- 3,000 PSI -GARAGE FLOORS - 3,500 PSI 3. THE GENERAL CC;NTRACTOR SHALL VERIFY ALL L?iMENSIONS ANY DISCREPANCIES " INCONSISTENCIES OR AMBIGUITIES SHALL BE REPORTED TO JCE PRIOR TO PROCEEDING WITH THE WORK. _ 4.' THE SILL PLATE OR FLOOR SYSTEM SHALL BE ANCHORED TO THE FOUNDATION WITH 5/8" 0 BOLTS PLACED 42" O.C. WITH 3"x3"xY¢" PLATE WASHERS AND V-12" INCHES FROM END AND CORNERS. BOLTS SHALL EXTEND A MINIMUM OF 15 INCHES INTO MASONRY OR SEVEN INCHES INTO CONCRETE. 5. A PERIMETER SEAL SHALL BE PROVIDED UNDER 2x6 PRESSURE TREATED SILL, 6. FOUNDATION WALLS SHALL EXTEND AT LEAST EIGHT INCHES ABOVE THE FINISHED GRADE ADJACENT TO THE FOUNDATION AT ALL POINTS. EXCEPTION: WHERE MASONRY VENEER IS USED, FOUNDATION WALLS `SHALT_. EXTEND A MINIMUM OF FOUR INCHES ABOVE THE FINISHED GRACE. 7. STEEL REINFORCEMENT SHALL CONFORM TO A.S.T.M. 615. GRACIE 60. jsA OF SMOKE DETECTOR LOCATION oma'' JOH 4 g CHURCNiit..i1R. (�( CARBON MONOXIDE DETECTOR LOCAMON o 1. .4160 2442 2442 2442: 2442 2442 �` is � UD HEAT DETECTOR LOCATION 7t-4» T 2" 6'-3" 4`-60 21'-8 " le-340,PROPOSED DWEEUING FOR: SARAJON REALTY LLC SCALE. 1 14"=10-0,r ' APPROVED BY: DRAVYN BY: S� l 36'-0" ! DATE: 7/31/17 REVISED: 8/11/17 SECOND FL0OR P L A fel ENGINEERING, PREPARED BY: SCALE: 1/4"=l' -O" JC E N IN E E R I N , I N C. _SECOND FLOOR AREA: 1008 S.F. 57 MELGO LANE DRAWNG NUMBER: YARMOUTH, MA B - - _ __ - - __ __ _ _ - .. e.�.� c..,.�..,�...i�e�f»ui.ixG.,�.s £: F.,-. I, ?: >; GENERAL NA LNG SCIAED LE 110 MPI•! EXPOSURE B WIN} TONE HEADERSPAN (FEET) MINIMUM HEADER SIZE REQUIREMENTSATEACH END OF HEADER JOB DESCRIPTION ROOF FRAMING NUMBER OF CONNANJ MALS 2-8d NLMER OF BOX NALS NAL SPACING BLOCMIGTO RAFTER 2-16d 2-10x1 EACH END RIM BOARDTORAFTER (END N UD) 4.164 3-16d EACH END WALL FRAMING' 416 193 4 TOP PLATE AT NTEFSE=M (FACE NAL 4.16d 5-16d ATJOINTS STUD TO STUD (FACE NALED) 2-16d 2-16d 24' O.G. WADER TO WADER (FACE HALED) 160 16d 16" O.C. ALONG EDGE S FLOORFRAMING 396 7 2-2X8 JOIST TO SLL, TOP PLATE OR GIRDER (TOE HALE p) 4-8d 4-10d PER JOIST BLOt3CNG TO JOIST (TOE NA LE?) 2.8d 2-10d EACH ESD BLOCKING TO SLL OR TOP PLATE (TOE HALED) 3-164 4-16d EACH BLOCK LEDGER STPdPMBEAM ORGIRDER: (FACE NALED) 3-16d 4-16d EACHJOIST JOIST ON LEDGER TO BEAM (TOE NA LED) 3-8d 3-10d PERJOIST BA NO JOIST TO JOIST (END NALED) 3.164 4-164PER JOIST BANDTOJOtSTTOSLL ORTOPRAlE(TOEN4LED) 216d 3-164 PER FOOT ROOF SWATH NG 3 1-20 FLAP 2 WOOD STRUCTURAL PA MIS 198 4 1-20 FLAT RAFTERS OR TRUSSES SPACED CPTO 16" O.C. 6d 10d 6" Ei7GEV FELD RAFTERS ORTRUSSSES SPACED OVER I6' O.C� 8d 10d r EDfaB4" FEW GABLE ENOlvALL RAKE OR RAKETF4JSS w/o GABLEOVEiRFIANG 8d 10d 6" EDGES" FEW GA BLE ENOWALL, RAKE OR RAKETRUSS w / STRUCTURAL OUTLOOKERS 6d 10d 6" EX-Et6' FL2t} GAEKEENNDWALL RAKEOR RAKETRUSS w / LOOKOUT BLOCKS 6d 10d 4' EiJW4" FIELD CEILING SWATNG 240 528 9 GYPSUM WALLBOARD Sd COOLERS 270 T eme t0" F eLD WALL SHEATHING 2-2X6 FLAT 4 300 1' OR LESS 8d 10d 6" EDW 12" FIE.D GREATER THAN 1' 10d 16d lir WSW FIELD NOTE UNLESS OTHSWNSE STATED, SIZES GIVEN FOR MALS ARE COM MON WIRE SIZES, BOX AND PNR AATIC NALS OF EDUIVAL E NT DIAMETER AND E OUA L OR GREATER LENGTH TO THE SPECIFIED COMMON NAL MAY SE SUBST rJ E7 UtdLEgS OTFOW4SE FROHWM, STUDS AND HEADERS AT WALL OPENINGS HEADERSPAN (FEET) MINIMUM HEADER SIZE REQUIREMENTSATEACH END OF HEADER NUMBER OF FULL HEIGHTSTUDS JUPLIFT (POUNDS) LATERAL (POUNDS) HEADERS IN LOAD BEARING WALLS 2 2-20 1 277 132 3 2-2X4 2 416 193 4 2-20 2 554 264 5 2-20 3 693 330 6 2-2X6 3 831 396 7 2-2X8 3 970 462 8 2-2X12 3 1108 528 9 3-2X10 3 1247 594 10 3-2X12 4 1385 660 11 4-2X10 4 1524 726 HEADERS IN NON -LOAD BEARING WALLS 2 1-2X4 FLAT 1 60 132 3 1-20 FLAP 2 90 198 4 1-20 FLAT 2 120 264 5 1-2X4 FLAT 3 150 330 6 1-2X6 FLAT 3 180 396 7 1-2X6 FLAT 3 210 462 8 1-2X6 FLAT 3 240 528 9 2-2X6 FLAT 3 270 594 10 2-2X6 FLAT 4 300 660 11 2-2X6 FLAT 4 330 726 1212-2X6 FLAT 5 360 792 (TY' ! I - – — BOTTOM FOOTING ELEVATION 4.83— FRONT ELEVATION SCALE: 1/41=11–(Yl NAIL. REQ. 6" EDGE NAILING, 12" FIELD NAILING BOTTOM PLATE TO FRAME (16d) 0 3/FT. TOP SPLICE LENGTH = 6- 20 (16d) NAILS EACH 'SIDE OF SPLICE CONTINUOUS RIDGE VENT f } (TYP) !! cONTRcroR sHALL LJ ( MAINTAIN 48" MINIMUM 12" SONOTUBE (TYP.) FROST PROTECTION (TYP.) BOTTOM FOOTING EL.EVATiON =4.83'— — — — — —— — 10" BIGFOOT SONOTUBE (TYP.) REAR ELEVATION SCALE: 1/4"=l'—O" NAIL REQ. 6" EDGE NAILING, 12" FIELD NAILING BOTTOM PLATE TO FRAME (16d) ® 3/FT: TOP SPLICE LENGTH = 6' 20 (16d) NAILS EACH SIDE OF SPLICE Yarmouth Health Department ..............M - _.__ .. W y uo _. w__ ame Date P.T. DECK AND RAILINGS FIRST FLOOR __.� _�_ _ �.—.—.—._.._.. _ N OF TOP OF FOUNDATION 11.5'............_ _ -� wL P:T. 2x10 016" U.C. ts� �L #� CHURCHILL JR. 12" SONOTUBE (TyP.) I , I .__ BOTTOM FOOTING ELEVATION = 4.83' PROPOSED DWELLING FOR: � �.. �_ SAAJOl� - __... �..� ..._ REALTY LL R. `J LJ E ELEVATION SCALE: i/4*=1*-0" APPROVED BY DRAWN BY: SII SCALE: 1/4"=l'—O" DAA: 7/31/17 REVISED: NAIL REO. PREPARED BY 6" EDGE NAILING, 12" FIELD NAILING � � ENGINEERING, 1 I V BOTTOM PLATE TO FRAME (16d) 0 3/FT. C. TOP .SPLICE LENGTH = 6' 57 MELGO LANE DRAWING NUMBER, 20 (16d) NAILS EACH SIDE OF SPLICE YARMOUTH, MAA PECK NOTES 1. USE 6x6 POSTS. POSTS MUST BE CENTERED ON FOOTINGS 2. ATTACH DECKING TO EACH )GIST WITH 2-84 THREADED NAILS OR 248 SCREWS. SPACE BOARDS APPROX.Y' APART. 3. RIM)OISTCONNECTIONDETAIIS a.) SECURE DECKING TO TOP OF RIM JOIST w/ 10i THREADED NAILS OR #10x? MIN. WOOD SCREWS 0 6" O.C. W ATTACH RIM )GIST TO END OF EACH 101ST w/ 3-1W THREADED NAILS 3-AOYS r MIN. WOOD SCREWS 4. FOOTINGS a.) ALL FOOTINGS SHALL BEAR ON SOLID GROUND AND SHALL BE PLACED AT LEASTI2" BELOW THE UNDISTURBED GROUND SURFACE OR BELOW THE FROSTLINE, WHICHEVER IS DEEPER. W POSTS MUST BE CENTERED ON FOOTINGS 0 FOOTING SIZE: 12' DIAMETER SONOTUBE 5. LAG SCREW REQUIREMENTS a.) EACH LAG SCREW SHALL HAVE PILOT HOLES DRILLED AS FOLLOWS: 1.) DRILLAY2" DIAMETER HOLE IN THE LEDGER BOARD 2.) DRILLA 5/16" DIAMETER HOLE INTO THE BAND BOARD OFTHE EXISTING HOUSE 3.) DO NOT DRILLAY2" DIAMETER HOLE INTO THE BAND BOARD 6. DECKS GREATER THAN T ABOVE GRADE SHALL BE PROVIDED WITH DIAGONAL (2x4) w/14/9' DIAMETER THRU-BOLTw/ WASHERS, PROVIDE DIAGONAL BRACING BOTH PARALLEL AND PERPENDICULAR TO BEAM AT EACH POST. 7. ALL DECKS GREATER THAN 30' ABOVE GRADE ARE REQUIRED TO HAVE A GUARD. DECK GUARD POSTS SHALL BEA MINIMUM 44 (NOMINAL) w/ AN ADJUSTMENT BENDING VALUE NOT LESS THAN 1,104 PSL 8. STAIR REQUIREMENTS a•) ALL STRINGERS SHALL BE A MINIMUM OF 2A2 W 10' MINIMUM TREAD WIDTH c.) 7-W MAXIMUM RISER HEIGHT d.)"-i"NOSING e,) 24 OR Y4 MINIMUM TREAD SIZE FOR A CUTSTRINGEK AND 2x6 MIN IMUM FOR A SOLID STRINGER (WHEN USING SOUTHERN PINE) 9. STAIR GUARD REQUIREMENTS a.) STAIR GUARD 15 REQUIRED FOR STAIMw/ATOTAL RISE OF50"OR MORE W STAIR GUARD HEIGHT= 34' MINIMUM AND 38' MAXIMUM MEASURED FROM THE NOSING OF THE STEP c.) ALLSTAIRS w/ 4 OR MORE RISERS SHALL HAVEA HANDRAIL ON AT LEASTI SIDE 2442 2442 2442 2442 2442 6'--3" 7'-4" 7' 2" 6'-3" 4'-6" 21'-S " 14`-3 36'-O" SECOND FLOOR PLAT SCALE: 1/4"=V-0" SECOND FLOOR AREA: 1008 S.F. EXISTING FOUNDATION ENCLOSURE: 1008 S.F. REQUIRED AMOUNT OF FLOOD VENTS: 10018 S.F. / 200 S.F. PER VENT I�� INSTALL 6 `;SMART VENTS AT NO ;MORE THAN 12" ABOVEGRACIE IN LOCATIONS ''SHOWN ON THIS SHEET. GEHERAL NOTES: 1. DWELLING IS LOCATED WITH FLOOD ZONE AE(EL. 11). 2. THE CONSTRUCTION OF THE FOUNDATION TO BE IN ACCORDANCE WITH SECTION 322 -FLOOD RESISTANT 'CONSTRUCTION OF THE EIGHTH ED171ON OF MASSACHUSETTS STATE BUILDING CODE. 3. BOTTOM OF FOOTINGS TO HAVE ADEQUATE FROST PROTECTION. REFER TO SITEPLAN FOR 'FINISH 'GRADES AROUND FOUNDATION. 4. SEE THIS SHEET FOR SMART VENT DETAILS AND REQUIRED OPENINGS IN WALL. 5. BOTTOM OF SMART VENTS TO BE INSTALLED NO MORE THAN 12" ABOVE FINISH GRADE. 6. THERE SHALL' BE i SQUARE INCH OF FREE VENT OPENING FOR EVERY 1 SO2. FT. OF FLUOR AREA. ' EACH SMART VENT IS CERTIFIED FOR 200 SQUARE FEET OF ENCLOSED FLOOR AREA. 7. SMART VENTS AVAILABLE FROM A.H. HARRIS & SONS,` INC., 3131 CRANBERRY HIGHWAY, EAST WAREHAM, ISA 02538, (508) 759-9990.- 8. 59-9990:8. REFER TO ARCHITECTURAL PLANS 'PREPARED BY WOODTEX, HIMROD, NEW YORK, PREPARED FOR MARCELLA HOLBROOK, DATED OCTOBER 27, 2016 FOR REMAINING BUILDING LAYOUT AND DETAILS. 9. EXTERIOR SHEATHING ON 'KNEE WALES SHALL BE NAILED WITH 8d COMMON NAILS AT 6" O.C. EDGE. SPACING AND 12" O.C. FIELD SPACING. EQUISDATION NOTES: 1. FOUNDATION DESIGN BASED ON THE FOLLOWING PRESUMED SOIL BEADING CAPACITES: CRYSTALLINE BEDROCK 12,000 PSF SEDIMENTARY ROCK - 4,000 PSF SANDY GRAVEL OR GRAVEL - 3,000 PSF SAND, SILTY SAND, CLAYEY SAND, SILTY GRAVEL AND CLAYEY GRAVEL - 2,000 PSF CLAY, SANDY CLAY, SILTY CLAY, AND CLAYEY SILT 1,500 PSF 2. CONCRETE SHALL REACH A' COMPRESSIVE STRENGTH OF (PSI) IN THE FOLLOWING LOCATIONS: -BASEMENT WALLS, FOUNDATION _WALLS, EXTERIOR ` WALLS AND OTHER VERTICAL CONCRETE WORK EXPOSED TO THE WEATHER 3,000 PSI -GARAGE FLOORS - 3,500 PSI 3. THE GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS ANY DISCREPANCIES, INCONSISTENCIES OR AMBIGUITIES SHALL BE REPORTED TO JCE PRIOR TO PROCEEDING WITH THE WORK: 4. THE SILL PLATE OR FLOOR SYSTEM SHALL BE ANCHORED TO THE FOUNDATION WITH 5/8" 0 BOLTS PLACED 42" O.C. WITH 3"x3"xY4" PLATE WASHERS AND 6"-12" INCHES FROM END AND CORNERS. BOLTS SHALL EXTEND A MINIMUM OF 15 INCHES INTO MASONRY OR SEVEN INCHES INTO CONCRETE. 5. A PERIMETER SEAL SHALL BE PROVIDED UNDER 2x6 PRESSURE TREATED SILL. 6. FOUNDATION WALLS SHALL EXTEND AT LEAST EIGHT INCHES ABOVE THE FINISHED GRADE ADJACENT TO THE FOUNDATION AT ALL POINTS. EXCEPTION: WHERE MASONRY VENEER IS USED, FOUNDATION WALLS SHALL EXTEND A MINIMUM OF FOUR INCHES ABOVE THE FINISHED GRADE. 7. STEEL REINFORCEMENT SHALL CONFORM TO A.S.T,M. 615. GRADE 60. �► op SMOKE DETECTOR LOCATION q JAI L CHURCHILUR. + O CARBON MONOXIDE DETECTOR LOCATION rs p HEAT DETECTOR LOCATION A. PROPOSED DWELLING FOR: ARAJON REALTY LLQ SCALE: 1 /4"=V--0" APPROVED BY: DRAWN BY: SJI BATE: 7/31 /17 REVISED: PREPARED BY. JO EIS I N EER I N,INC* 5.1 MELGO LANE,bRAwING NUMBER: YARMOUTH, MA L B' 3" 572' �0 m LINEN s�C(D I m I m o � to BEDROOM #3 ;m< . BATH a N I /'""� CLOSET I N LINEN o�� cy o •- 2'-10` 266 ry*o�Og epb�e I � ATTICi � I � �, SD SD 6d, STAIRCASE Pol �.�D cs�p w I I ;,� 00N 3 2X1 � - _ r _. _.r _ ;� LINEN � ��, I, � 2 - 200 ABOVE 2 - 2x10 ABOVE `� A n Dowty 114tCHASE �p 13'- 8 - kN L 2"-10" cn f^� BEDROOM #4 BEDROOM #2- 04 04 2 10 16" V.C. _TA FF t0 2442 2442 2442 2442 2442 6'--3" 7'-4" 7' 2" 6'-3" 4'-6" 21'-S " 14`-3 36'-O" SECOND FLOOR PLAT SCALE: 1/4"=V-0" SECOND FLOOR AREA: 1008 S.F. EXISTING FOUNDATION ENCLOSURE: 1008 S.F. REQUIRED AMOUNT OF FLOOD VENTS: 10018 S.F. / 200 S.F. PER VENT I�� INSTALL 6 `;SMART VENTS AT NO ;MORE THAN 12" ABOVEGRACIE IN LOCATIONS ''SHOWN ON THIS SHEET. GEHERAL NOTES: 1. DWELLING IS LOCATED WITH FLOOD ZONE AE(EL. 11). 2. THE CONSTRUCTION OF THE FOUNDATION TO BE IN ACCORDANCE WITH SECTION 322 -FLOOD RESISTANT 'CONSTRUCTION OF THE EIGHTH ED171ON OF MASSACHUSETTS STATE BUILDING CODE. 3. BOTTOM OF FOOTINGS TO HAVE ADEQUATE FROST PROTECTION. REFER TO SITEPLAN FOR 'FINISH 'GRADES AROUND FOUNDATION. 4. SEE THIS SHEET FOR SMART VENT DETAILS AND REQUIRED OPENINGS IN WALL. 5. BOTTOM OF SMART VENTS TO BE INSTALLED NO MORE THAN 12" ABOVE FINISH GRADE. 6. THERE SHALL' BE i SQUARE INCH OF FREE VENT OPENING FOR EVERY 1 SO2. FT. OF FLUOR AREA. ' EACH SMART VENT IS CERTIFIED FOR 200 SQUARE FEET OF ENCLOSED FLOOR AREA. 7. SMART VENTS AVAILABLE FROM A.H. HARRIS & SONS,` INC., 3131 CRANBERRY HIGHWAY, EAST WAREHAM, ISA 02538, (508) 759-9990.- 8. 59-9990:8. REFER TO ARCHITECTURAL PLANS 'PREPARED BY WOODTEX, HIMROD, NEW YORK, PREPARED FOR MARCELLA HOLBROOK, DATED OCTOBER 27, 2016 FOR REMAINING BUILDING LAYOUT AND DETAILS. 9. EXTERIOR SHEATHING ON 'KNEE WALES SHALL BE NAILED WITH 8d COMMON NAILS AT 6" O.C. EDGE. SPACING AND 12" O.C. FIELD SPACING. EQUISDATION NOTES: 1. FOUNDATION DESIGN BASED ON THE FOLLOWING PRESUMED SOIL BEADING CAPACITES: CRYSTALLINE BEDROCK 12,000 PSF SEDIMENTARY ROCK - 4,000 PSF SANDY GRAVEL OR GRAVEL - 3,000 PSF SAND, SILTY SAND, CLAYEY SAND, SILTY GRAVEL AND CLAYEY GRAVEL - 2,000 PSF CLAY, SANDY CLAY, SILTY CLAY, AND CLAYEY SILT 1,500 PSF 2. CONCRETE SHALL REACH A' COMPRESSIVE STRENGTH OF (PSI) IN THE FOLLOWING LOCATIONS: -BASEMENT WALLS, FOUNDATION _WALLS, EXTERIOR ` WALLS AND OTHER VERTICAL CONCRETE WORK EXPOSED TO THE WEATHER 3,000 PSI -GARAGE FLOORS - 3,500 PSI 3. THE GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS ANY DISCREPANCIES, INCONSISTENCIES OR AMBIGUITIES SHALL BE REPORTED TO JCE PRIOR TO PROCEEDING WITH THE WORK: 4. THE SILL PLATE OR FLOOR SYSTEM SHALL BE ANCHORED TO THE FOUNDATION WITH 5/8" 0 BOLTS PLACED 42" O.C. WITH 3"x3"xY4" PLATE WASHERS AND 6"-12" INCHES FROM END AND CORNERS. BOLTS SHALL EXTEND A MINIMUM OF 15 INCHES INTO MASONRY OR SEVEN INCHES INTO CONCRETE. 5. A PERIMETER SEAL SHALL BE PROVIDED UNDER 2x6 PRESSURE TREATED SILL. 6. FOUNDATION WALLS SHALL EXTEND AT LEAST EIGHT INCHES ABOVE THE FINISHED GRADE ADJACENT TO THE FOUNDATION AT ALL POINTS. EXCEPTION: WHERE MASONRY VENEER IS USED, FOUNDATION WALLS SHALL EXTEND A MINIMUM OF FOUR INCHES ABOVE THE FINISHED GRADE. 7. STEEL REINFORCEMENT SHALL CONFORM TO A.S.T,M. 615. GRADE 60. �► op SMOKE DETECTOR LOCATION q JAI L CHURCHILUR. + O CARBON MONOXIDE DETECTOR LOCATION rs p HEAT DETECTOR LOCATION A. PROPOSED DWELLING FOR: ARAJON REALTY LLQ SCALE: 1 /4"=V--0" APPROVED BY: DRAWN BY: SJI BATE: 7/31 /17 REVISED: PREPARED BY. JO EIS I N EER I N,INC* 5.1 MELGO LANE,bRAwING NUMBER: YARMOUTH, MA L B' II 1x8 1S" O.C. i 15# BUILDING PAPER B.YU. 12 8 % R-30 FBGLS. INSUL p. 1 ( So THK x 5'-10" 1X FASCIA W t CONC WALL. ON CONTRACTOR SHALL ALUMINUM GUTTER SMART VENT CONT 20"x1O" CONC. MAINTAIN 48" MINIMUM7' (TVP: FOR.. S), FOOTING FOOTING COVERAGE 2x10 0 16" Q.C. • SEE DETAIL AND 2x10 16 O.C. CEILING JOIST NOTES1 -1 2 1{3 J 16" lc,m 1 2" GYP BD (( / 1X SOFFIT 1 I ON ALL INT. WALLS 1X FRIEZE - S 1/2- CONC. FILLED I STL. LALLY COLUMN I ON 36 x36 x10 DP CONT. 6" SEWER SLEEVE coI BEDROOM R-21 FBGLS. INSUL CONC. FOOTING, TYP k •{ BEDROOM { � N 7 w5 ' -4 1-cr 5 -O .5# -O 4--11 3/4- T&G PLYWOOD SUB -FLOOR GLUED AND NAILED, TYP SECOND FLOOR. o <o 2x10 ® 16 O.C. 2x10 `0 16 Q.C. IN 4-2x10BEAM r L1 2"GYP BD f 2X6�f16 O.C. ON ALL INT. WALLS .....,.,.._........� ._.,.... — ,..-.r ...-.. _.._. ,..�... ......:.�.....:,_ �........,� — �.,. _ ._..� 1 f2" OSB SHEATHING SHIM BEAM IN I CRAWL SPACE: _ DINING ROOM 1/2N GWB POCKET �€ MIN BEARING(TYP;) SLAB ELEV. - 9.0' " ii ao KITCHEN VAPOR BARRIER SN 4 MIN. CONC. SLAB 2 10 16"I.C. (3000 PSI) WITH TYvEK wQUSEWRAP 1 -8 EXPANSION JOINTS OVER COMPACTED SOIL ELECTRIC PANEL SIDING (SEE ELEVS.) (GROUNDING ROD TO CONNECT TO REBAR 3/ N T&GLUE AND NAILED, SUB-FLOOR FIRST FLOOR I ._ — ...�. ...._... � . IN FOUNDATION} Z� R-30 FBGLS. INSUL 2x0 16" O.G. Td --I I =1II _ CRAWL SPACE = — BOTTOM FTG = 4.83`jIIII� `° o RIM JOIST 4-2x1 a BEAM TOF 11,5 — � a 1 � -!III N +n 4" CONC. SLAB (2) 2X6 P.T .SILL 8" POURED CONC. WALL 4 WATER SLEEVE i — . _ .. _.. ..._ W SILL SEALER BASEMENT SLAB DOUBLE JOISTS UNDER � � .�. ..� _.�. ....�. ..�._ ....-... . ALL PARALLEL PARTITIONS_90MPA�M_P 61 — — — B.W. FLLJI 4'-0" 4•-0' 4'-0" 1E` -O" 8,-0" SECTION A " A 36'-0" �. SCALE: 1/4"'=V-0 FOUNDATION PLAN - SCALE: 1/4"=V-0" i 16-114' ROUGH OPENING E'XTER17 INTL'Rig a o DOOR UPPER STRAPS ALTERNATE STRAP REMOVED 7 LOCATIONS ON SIDES "" + > BEHIND WALL N > ALTERNATE i5-114` OPEN _ .. 5 , SIDE STRAPS` A: BEHIND WALL OPEN C' .., 2'x 15-1P4' OPEN 8-114' ROUGH _ _ 8-114` HIGH X OPENING .�-„_ 16-1/4' WI➢c ROUGH OPENING 3-0' OPEN Cl'� FRAME 3'x 15-1/4' OPEN DOOR Rarsr OPEN DCCP � � 7 SHOWN OPEN FRAME IN FRAME � BOTTOM STRAPS > BEHIND WALL STRAPS CSO BEHIND WALL MAXs AND CAN BE BROKEN OFF 7 ° AT SLOTS 'TO AVOID ' > a OBSTRUCTIONS FINAL GkAIIE ' > > EXTERIOR VIEW SIDE SECTION VIEW SMART VENT DETAIL (NOT TO SCALE) 1. PREPARE A CLEAN 16-1/4" WIDE BY 8-1/4" HIGH ROUGH OPENING FOR EACH VENT (1 BLOCK WIDE ot;OF SMOKE DETECTOR LOCATION x i BLOCK HIGH) WITH THE BOTTOM OF THE HOLE NO MORE THEN 12" ABOVE FINISHED GRADE. #,D 2. MEASURE WALL THICKNESS AND BEND (MARE THAN 90') 4 STRAPS AT NEAREST SLOT TO THEJOHNIL+ MEASUREMENT FROM POINTED ENCS. CHURCHu,l�t. C CARBON MONOXIDE DETECTOR LOCATION 3. REMOVE DOOR FROM FRAME. (TURN UPSIDE DOWN, ROTATE BOTTOM OF DOOR OUTWARD AND SLIDE NO OUT OF SLOTS)ND 4. INSERT TWO STRAPS INTO TWO TCP SETS OF SLOTS IN FRAME FROM REAR. AFTER PUSHING TEETH I� HEAT DETECTOR LOCATION THROUGH REAR SET SLOTS, ONLY PUSH STRAPS ONE CLICK INTO FRONT SLOTS. STRAPS SHOULD HAVE BENT LEGS POINTING UP. 5. CAULK MAY BE APPLIED BEHIND FRONT FRAME FLANGE. TILT FRAME SO TOP GOES INTO WALL OPENING FIRST WITH STRAP LEGS GOING BEHIND WALL ABOVE OPENING. PUSH FRAME INTO OPENING SO FRONT FLANGE IS TIGHT TO FACE OF WALL. 6. REACH THROUGH FRAME OPENING AND INSTALL TWO BENT STRAPS THROUGH TWO BOTTOM SETS OF SLOTS IN FRAME, TRAPPING WALL BETWEEN FRONT FLANGE AND BENT STRAP. SQUEEZE ALL STRAPS TIGHT. FRAME SHOULD BE FLUSH TO WALL FACE AND SECURE. A R A`J PROPOSED DWELLING FOR - C n REALTY O N 1 � E A L TY L L C 7. CHECK THAT FRAME IS SQUARE AND SLOTS ARE CLEAR OF DEBRIS, MORTAR AND CAULK. SCALE. IAPPROVED E3Y: InPAMN RY• _ .. 8. INSTALL DOOR INTO FRAME BY GRASPING BOTTOM OF DOOR (WITH PLASTIC PINS) AND FRONT (WITH SMALLER SQUARES) FACING UP. SLIDE DOOR INTO FRAME SUCH THAT METAL PINS ON EACH SIDE SLIDE INTO SLOTS ON SIDES OF FRAME. LET THE DOOR SLIDE DOWN FOLLOWING THE PATH OF THE SLOTS, UNTIL THEY ARE AT THE BOTTOM OF THE SLOTS IN THE DIMPLES. 9. LET THE BOTTOM OF THE DOOR GQ SO THAT THE DOOR ROTATES DOWN INTO THE FRAME. CHECK THAT DOOR IS LATCHED ON BOTH SIDES. tQ, Yo TR1PL8 HEADER .TACK O I t STUD DBL TOP PLATE DOUBLE o STUD r II 2x STUDS 0 16 Q.G. r- I i l [ i I 3/4" PLYWOOD SUBF'LOOR ( BTM PLATE PLATE o 0 0 � o RIM JOIST i AT 2nd STORY r LOCATIONS EXTERIOR WALL OPENINGS, HEADER i DBL TOP PLATE DETAILS WITH .JACK STUDS � �. ,. NOT TO SCALE 1 2x STUDS 0 16" O.C. GE3 ERAL NAILING SCHEDULE t 10 tit EXPOSURE 8 WND zC .MINIMUM HEADERSPANYY� � (FEET) M __....__ HEADER SIZE REQUIREMENTS ATEAOH END OF HEADER JOB DESCRIPTION NUMBER OF COMMON MALS NUMBER OF BOX MALS NAIL SPACING ROOF FRAMING BTM PLATE 1 277 BLOCKING TO RAFTER 2-16d 2-10d . RIM BOARD TO RAFTER (END NA LED) 4-16d 3-16d EACH FI D WALLFRAMING 554 264 5 TOP PLATE AT HTERSIECTIONS(FACE MLED) 4.164 i ATJOINTS STUD TO STUD (FACE NA LED) 2-16d 2-16d 24" O.C. HEA DER TO HEADER (FACE HALED) FLOOR FRAMING 16d 16d 16" O.C. ALONG EDGES JOIST TO SLL, TOP PLATE OR GMER (TOENALED) 4-6d 4.104 PERJOIST BLOCKING TO JOIST (TOE NA LED) 2-6d 2-10d EACH DO BLOCKING TO SLL OR TOP PLATE (TOE NALM 3.16d 4-16d EACH BLOCK LEDGER STEPTOBEAM ORGIS(FACE HALED) 3-16d 4-16d EACHJOIST JOiST ON LEDGER TO BEAM (TOE NALED) 3-6d 3-10d PER JOIST BAN? JOIST TO JOIST (DO NALED) 3-16d 4-16d PER JOIST BANDTO JOIST TO SILL OR TOP PLATE (TOE NA LED) ROOF SHEATH1iNCr 2-16d 3.164 PER FOOT WOOD STRUCTURAL PANELS 3 1-2X4 FLAT 2 RAFTERS OR TRUSSES SPACED LP TO 16' O.C. sd 10d 6" EDGE76" FELD RAFTERS OR TRUSSSES SPACE) OVER 16'0.C. 8d 10d RIM JOIST GABLEEJDWALL RAKEORRAKETRUSS w to GA8LE OVB;61ANG 6d 10d 6" EDWS* FELD GABLEE3+DWALL RAKE OR RAKETRUSS w STRUCTURAL QUrLOOKERS 6d 14d 6' EDGI� FIELD GA BLE eMALL RAKE OR RAKE TRUSS wI LOOKOUT BLOCKS CEDLNG SWATNG 6d 10d 4" 1 X 41' FELD GYPSUM WALLBOARD .r 8 7" EDGE! 10' HELD WALL SFEATHNG 240 528 < . 1' OR LESS 4. b , 10d 6' EDS& 12" FIELD LOOR JOISTS 110d 16d 8" EDGEI6" FW NOTE UNLESS OT fRWISE STATE), SIZES GIVEN FOR NALS ARE COIN WRE SIZES, BOX AND PNEUMATIC NA LS OF E LWALENT DIAMETER AND EQUAL OR GREATER LENGTH TO THE SPECIFIC COMMON NAL MAY BE SUBs=rrm Lmess OTFImmE PROHISM, .• 2-2X6 FLAT 4 330 726 1122-2X6 FLAT `, • t- 360 . • . c SILL LATE P BOLTS w/ < -• A Id E WASHERS44 .4 :. •' 4 Q , ' 4 1/2- WOOD STRUCTURAL PANELS `` � . a s 4 n I P r SILL LATE TO TOP -PLATE .. • < 4 y SEE NAILING SCHEDULE ° a , a.z. 1 .: 4` a - . ._ a d • a. SILL PLATE` �. f . SILL TO PLATE WITH < WOOD STRUCTURAL PANELS yy 4 . • z < d a. 4 ,. : # NOT TO SCALE r • • a: GE3 ERAL NAILING SCHEDULE t 10 tit EXPOSURE 8 WND zC .MINIMUM HEADERSPANYY� � (FEET) M __....__ HEADER SIZE REQUIREMENTS ATEAOH END OF HEADER JOB DESCRIPTION NUMBER OF COMMON MALS NUMBER OF BOX MALS NAIL SPACING ROOF FRAMING 2-6d 1 277 BLOCKING TO RAFTER 2-16d 2-10d EACH ESD RIM BOARD TO RAFTER (END NA LED) 4-16d 3-16d EACH FI D WALLFRAMING 554 264 5 TOP PLATE AT HTERSIECTIONS(FACE MLED) 4.164 5.16d ATJOINTS STUD TO STUD (FACE NA LED) 2-16d 2-16d 24" O.C. HEA DER TO HEADER (FACE HALED) FLOOR FRAMING 16d 16d 16" O.C. ALONG EDGES JOIST TO SLL, TOP PLATE OR GMER (TOENALED) 4-6d 4.104 PERJOIST BLOCKING TO JOIST (TOE NA LED) 2-6d 2-10d EACH DO BLOCKING TO SLL OR TOP PLATE (TOE NALM 3.16d 4-16d EACH BLOCK LEDGER STEPTOBEAM ORGIS(FACE HALED) 3-16d 4-16d EACHJOIST JOiST ON LEDGER TO BEAM (TOE NALED) 3-6d 3-10d PER JOIST BAN? JOIST TO JOIST (DO NALED) 3-16d 4-16d PER JOIST BANDTO JOIST TO SILL OR TOP PLATE (TOE NA LED) ROOF SHEATH1iNCr 2-16d 3.164 PER FOOT WOOD STRUCTURAL PANELS 3 1-2X4 FLAT 2 RAFTERS OR TRUSSES SPACED LP TO 16' O.C. sd 10d 6" EDGE76" FELD RAFTERS OR TRUSSSES SPACE) OVER 16'0.C. 8d 10d 4" EDW41" FELD GABLEEJDWALL RAKEORRAKETRUSS w to GA8LE OVB;61ANG 6d 10d 6" EDWS* FELD GABLEE3+DWALL RAKE OR RAKETRUSS w STRUCTURAL QUrLOOKERS 6d 14d 6' EDGI� FIELD GA BLE eMALL RAKE OR RAKE TRUSS wI LOOKOUT BLOCKS CEDLNG SWATNG 6d 10d 4" 1 X 41' FELD GYPSUM WALLBOARD 5d COOLERS 8 7" EDGE! 10' HELD WALL SFEATHNG 240 528 9 1' OR LESS 6d 10d 6' EDS& 12" FIELD GREATER THA N 1" 110d 16d 8" EDGEI6" FW NOTE UNLESS OT fRWISE STATE), SIZES GIVEN FOR NALS ARE COIN WRE SIZES, BOX AND PNEUMATIC NA LS OF E LWALENT DIAMETER AND EQUAL OR GREATER LENGTH TO THE SPECIFIC COMMON NAL MAY BE SUBs=rrm Lmess OTFImmE PROHISM, STUDS AND HEADERS AT WALL OPENINGS .MINIMUM HEADERSPANYY� � (FEET) M __....__ HEADER SIZE REQUIREMENTS ATEAOH END OF HEADER NUMBER OF FULL , .....a�. HEIGHTSTUDS UPLIFT _ _ _ m _... .. (POUNDS) LATERAL __•... N (POUNDS) HEADERS IN LOAD BEARING WALLS 2 2-2X4 1 277 132 3 2-2X4 2 416 198 4 2-2X4 2 554 264 5 2-2X4 3 693 330 6 2-2X6 3 831 396 7 2-2X8 3 970 462 8 2-2X12 3 1108 528 9 3-2X10 3 1247 594 10 3-2X12 4 1385 660 11 4-2X10 4 1524 726 HEADERS IN NON -LOAD BEARING WALLS 2 1-2X4 FLAT 1 60 132 3 1-2X4 FLAT 2 90 198 4 1-2X4 FLAT 2 120 264 5 1-2X4 FLAT 3 150 330 6 1-2X6 FLAT 3 180 396 7 1-2x6 FLAT 3 210 462 8 1-2X6 FLAT 3 240 528 9 2-2X6 FLAT 3 270 594 10 2-2X6 FLAT 4 300 660 it 2-2X6 FLAT 4 330 726 1122-2X6 FLAT 5 360 792 ANCHORAGE OF SILL T'C1 FOUNDATION WALL NOT TO SCALE STUD RAFTER RAFTER OR TRUSS SUBFL:OORING DOUBLE PLATE BAND SILL BLOCKING @ 48" O.C. JOIST ad a , STUD WALL. STUD EXTERIOR LL FLOOR FRAMING AT WA XTER OR FRAMING AT GABLE ENDS ROOF BRACE DETAIL - NOT TO SCALE NET TO SCALE NOT TO SCALE RESIDENTIAL BUILDNG DESIGN CRITERIA 2.1 FOUNDATION 780 CMR Concrete shall be a minimum 3,000 PSI at 28 days. THE STATE OF MASSACHUSETTS STATE BUILDING CC)DE STATE BOARD OF BUILDING REGULATIONS & STANDARD S 2.2 FOUNDATIUN ANCHORAGE Provide " " " Provide 5/8 diameter by 12 Ion b 3 hook Eighth Edition of the Massachusetts S Building g tate ;3rul ding Code . " ea Anchor bolts 42 CI.C. WI ' " ' � with 3 X 3 X 1/4 later: p n and (One Two Family D { Dwelling Code Y g ; �� " ; Provide an anchor bolt 6 to 12 from comer. WOOD FRAME CONSTRUCTION MANUAL - WFCM 3.1 FLOORS 110 MPH EXPOSURE B The clears an of floor joist shall r P 1 meet o Guide to Wood Construction in High Wind ,Areas exceed the values set forth in 780CMR 8th Edition. For one and two family Dwellings.,` 5.1 ROOF Wind speed is equal to or greater than 110 mph; Floor openings shall not exceed the lesser of NOTE: IT IS THE INTENT TO PROVIDE A CONTINUOUS LOAD 12'-0" or 50% of the building' dimension, U2 or W/2. PATH, THE INTERCONNECTION OF ALL FRAMING 3.2 FLOOR BRACING ELEMENTS IS CRITICAL TO A WIND- RESISTIVE Blocking and connections shall be provided at BUILDING. A CONTINOUS LOAD PATH OF panel edgesperpendicular to floor framing INTERCONNECTED FRAMING ELEMENTS FROM members In the first two' truss or joist spaces FOOTINGS AND FOUNDATION WALLS TO FLOORS, and shall be 46'O.C. see Floor BracingDetail. WALLS, AND ROOF FRAMING SHALL BE PROVIDED, the span permitted for ' P p e 20psf roof live load Aspect Ratio (L/W); 1.20 4.1 WALLS 1.1 SCOPE Loadbeann walls shall no '- "' i � t exceed 10 10 in height. 1.3 FRAMING Non'-loadbearing wall shell not exceed 20'-0" In height. Table F2301,2(4) Massachusetts Basic Wind Speeds Provide minimum 1 by 8 collar/rafter ties at 32" Town., Yarmouth, Basic Wind Speed 110 mph 4.2 EXTERIOR WALLS Provide framing connections per General Nailing Schedule. Maximum Loadbearing Stud Length R301.2.1.4 Exposure Category . ,-9 +1 2by 4 #2 at 1611 O.0 9 1 Exposure A: City 2 by 6 #2 at 16" O.0 9'-91' 2 Exposure B: Urban, Suburban Maximumo - N n iQadbearing-Stud Length 3 Exposure C: Open Terrain 2 by 4 #2 at 16" O.C; 11'-5" 4 Exposure D: Flat Unobstructed 2 by 6 #2 at 16" O.C. 18'-5" Exposure B: Yarmouth Gable' Walls Guardrails in fill components; 50 psf Shall be braced for a distance of at least 1/3 Table R301.2(5) Massachusetts Ground Snow Loads of the building width with wood structural panels Town: Yarmouth, Snow Load; 30 psf or at least 90% of the building width with 8301.2.1.2 Protection of openings gypsum wall board, Windows in wind bome debris regions shall have _ Story to StoryU lift and Lateral Connections see Detail. :Glazed Glazed openings protected from wind bome debris In accordance with Large Missile Test of ASTM E Studs & Headers at Wall Openings" see Table. 1996 and of ASTM E 1886. Exception; Wood structural panels, 7/16" by 8'-0" 4.3 EXTERIOR WALL SHEATHING Shall be permitted for opening protection In one Provide 7/16" wood structural panel sheathingon ' And two stn build' d 1 ry Ings (n actor ante with Tab a 8301.2.1.2 and the IBC. Contractor to provide labeled, all exterior walls. Provide the minimum required percentage ht sheathing see Tables 9 g a es 10 & re- screwed numbered, p wood structuralanels P a 11 in the Wood Frame Construction Manual 110 to be utilized in the case of a hurricane. MPH Ex. B. R202 Definitions Exterior wall sheathing shall be nailed with edge nailingas specified P Wind -home debris region. Areas within " • on Sheet A and '12 O.C. field, with 8d common nails. hunicane-prime regions within one mile of the coastal mean high water line where the basic 5.1 ROOF Wind speed is equal to or greater than 110 mph; Roof span shall not exceed 36'-0" or where the basic wind speed is equal Roof openings shall not exceed the lesser of to or greater than 120 mph. 12'-0" or 50% of the building dimension, U2 or W/2. 1.2 APPLICABILITY Roof slope shall not be greater than 12/12. Two Story, 2,016 SF 5.2 WOOD RAFTERS The clear span of rafters shall meet or exceed Roof Pitch; 8/12 the values set forth in 780CMR 8th Edition. The Mean Roof Height; 29'-1" t maximum rafter span shall be limits 34 of p d to 1 Building Length x Width; 36'-0" by 28'-U' the span permitted for ' P p e 20psf roof live load Aspect Ratio (L/W); 1.20 case, not to exceed 26-0". Nominal Height of Tallest Opening; 6'8" Provide Simpson H2.5 uplift connectors at each 1.3 FRAMING Rafter or truss: General framing connections shall be In Provide minimum 1 by 8 collar/rafter ties at 32" Accordance with 780CMR 8th Edition unless noted. O.C. located in the upper third of the attic space Provide framing connections per General Nailing Schedule. and attached to rafters using 5-10d nails at R301.5 Live Load each end. Minimum uniformly distributed live loads, Table R301.5: 5.3 ROOF SHEATHING Attics with Storage; 20 psf Attics without storage; 10 psf Provide 7/16" wood structural , ra panel sheathing onallroofs. Exterior Balconies and Decks; 40 psf 5.4 ROOF BRACING ENDWALL Fire Escapes; 40 psf Blocking and connections shall be provided at Guardrails, Handrails 200 lbs. panel edges perpendicular to roof framing Guardrails in fill components; 50 psf members in the first two truss or rafter spaces Passenger vehicle garage; 50 psf and shall be 48" O.C. see Detail. Rooms other than sleeping; 40 psf Sleeping Rooms; 30 psf Stairs, 40 psf R301.7 Deflection The allowable deflection shall not exceed Table R301.7 Rafters greater than 3/12; L1180 Interior Walls; H/180 Floors and Ceilings; 0360 Exterior Walls, stucco; H/360 Exterior Walls, brittle; H/240 Exterior Walls, flexible; U120 —STUD WALL --BOTTOM PLATE JOIST OR TRUSS RAFTER @ 16" O.C. CHURCHILL a H2.5 0 EA. RAFTER t1 0 — - TOP PLATE BLOCKING @ 48" O.C. —STUD WALL PROPOSED DnLLING FOR: AAJON REALTY L.L. SCALE: 1/4"_1'—O» APPROVED BY: DRAWN BY. S.J.1. FLOOR BRACE DETAIL TYPICAL RAFTER TO PLATE CONNECTION DATE. 7/31/17 REVISED. NOT TO SCALE NOT TO SCALE PREPARED BY; JC ENGIINEERING, 1 51 MELGO LANE DRAWING NUMBER: YARMOUTH, MA D ' _RA = �10.3't 4 SCHEDULE 40 PVC MIN. SLOPE 1% 9.4 - 10.3 .+ d S FINISHED GRADE OVER CHAMBERS - p-�, r�-� TOP OF FOUNDATION= � � .5O � FINISH GRADE OVER D -BOX � � t,� � . � I �, �, ��,, . , � � TES PROVIDE EXTENSION RISER SLOPE @ 2°% MIN. FINISH GRADE OVER TANK EL.= � FINISHED GRADE WITH COVER OVER INLET & REMOVABLE WATER -TIGHT COVER OVER I INSPECTION PORT BOX TO 1 • UNLESS OTHERWISE NOTED, ALL SYSTEM COMPONENTS AND CONSTRUCTION FOUNDATION =9.5'± OUTLET TO WITHIN 6 OF F.G. 10.5'± RISER TO WITHIN 6" OF FINISHED GRADE l INSP WITH ACCESS O METHODS SHALL BE IN ACCORDANCE WITH TITLE 5 OF THE STATE ENVIRONMENTAL -- -_ WITHIN 3 OF F.G. (SEE PLAN) 5" DIA. OUTLET(S) j CODE AND ANY APPLICABLE LOCAL RULES. 30"MIN. ACCESS 9" MIN. 2. ANY CHANGES TO THIS PLAN MUST BE APPROVED BY THE BOARD OF HEALTH AND THE PROP. 4" SCH. 40 COVER (3 NP.) 36"MAX. ; PROVIDE EQUALIZERS ; DESIGN ENGINEER. PVC SEWER PIPE 9„ MIN- ON EACH OUTLET (TYP.) 9" MIN. PROP. 4" SCH. 40 36 MAX. 36" MAX. TOP OF SAS ! B.O. = 8.41' 3. 4" SCHEDULE 40 PVC PIPE WITH WATER TIGHT JOINTS SHALL BE USED IN DISPOSAL PVC SEWER PIPE SYSTEM UNLESS OTHERWISE NOTED. E L - 231± 2" DROP MIN. 4. TO PREVENT BREAKOUT THE PROPOSED FINISHED GRADE SHALL NOT BE LESS THAN ' , M,N.s�oPe��� 6" 3" 3" DROP MAX. 3„ 9„LoPE @,% L - 4 t PROVIDE WATERTIGHT I ELEVATION = 8.41 FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE SAS. UNLESS A J13" 4" PVC IN FROMLLJOINTS YP.n*n1. 8' r7.1 - „ 40 MIL GEOMEMBRANE LINER IS PLACE AT LEAST FIVE FEET FROM S.A.S. AND THE TOP OF 8.85' 14" SEPTIC TANK 4 PVC OUT TO t P. 13 SE OT - 21/ (iY ) THE LINER IS NOT LESS THAN THE BREAKOUT ELEVATION. 8.30 LEACHING FACILITY 0.59' MYP) t 5. SLOPE ALL SOLID PIPE AT 1.0% MINIMUM. 5.55 6. THIS SYSTEM IS NOT DESIGNED FOR A GARBAGE DISPOSAL.48" OUTLET TEE 8.2MIN. 8.05' 7.92' 7.33' (laid flat) 2.875' (34.5")� I ( I 7. LOCAL BOARD OF HEALTH AND DESIGN ENGINEER TO BE NOTIFIED PRIOR TO BACK GAS BAFFLE 6" CRUSHED STONE 5'0 (TYP.) FILLING WHEN SYSTEM IS NEARLY COMPLETE AND READY FOR INSPECTION. SYSTEM IS OVER MECHANICALLY (TYP.) 5' MIN. 14.38' REQ D NOT TO BE BACK FILLED WITHOUT FIRST OBTAINING APPROVAL FROM BOARD OF HEALTH 23.4' TO FOUNDATION I COMPACTED BASE i 5 30.0' � AND DESIGN ENGINEER. OUTLET DISTRIBUTION BOX 8. ELEVATIONS BASED ON NAVD 88 DATUM. BENCHMARK ELEVATION OF 8.68 ESTABLISHED ON ` 6" CRUSHED STONE TO BE INSTALLED ON A LEVEL STABLE OVER MECHANICALLY GROUND WATER ELEV.= 2.33' A NAIL IN A UTILITY POLE AS SHOWN ON PLAN. BASE. FIRST TWO FEET OF OUTLET: � COMPACTED BASE I 9. CONTRACTOR SHALL VERIFY ALL UTILITY LOCATIONS PRIOR TO CONSTRUCTION PIPES TO BE LAID LEVEL. CHAMBERS (PROFILE) CHAMIBERS (END VIEW) PROPOSED '1,500 GALLON CONCRETE SEPTIC TANK ¢ THROUGH DIG -SAFE AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE AT n i 5'_ 11 (Dimensions perWiggin (Y 11FiLTRAT(RYSTE1, i3.} LENGTH 10-6 WIDTH 5 -8 DEPTH _ A � CRDSS SECTION VIEW 1 -888 -DIG -SAFE AND ANY OTHER APPLICABLE AGENCIES. REPORT ANY DISCREPANCIES §sw _ .�... Precast Cor1LEp., Pacasset, M) ,-, . .�,,. 110- � ! J �--- �t.� /`'; 13 � � , r ; TO THE DESIGN ENGINEER. ((-�� " ,w ,. �'i. { 1, e•' p"..^.' g - �, �e 1 : '^,.d ..r 'a. � J 3 t � � .e° �.^e. d ^$ w.� t . 1 (/� 110. ALL JOINTS WHERE PIPE ENTERS AND EXITS CONC. STRUCTURES SHALL BE MADE WATERTIGHT. j NOT TO SCALE ` NOT TO SCALE NOT TO SCALE g 11. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING i 1 ti?i%• i 1 1 , , `3, 1, REGULATIONS. OWNEWAPPLICANT IS TO OBTAIN SUCH DETERMINATION FROM PROPOSED �,�I O I ' ,, .,} tr l /r. APPROPRIATE AUTHORITY. MAP 33 1,500 GALLON F , 1 \1 o .,/.13 LOT 369 SEPTIC TANK �%, - 1 e r •. INSPECTOR: Amy Vonhone 12. ALL SEPTIC SYSTEM COMPONENTS SHALL WITHSTAND H-10 LOADING UNLESS LOCATED _ _„ ,t r ! • UNDER MORE THAN 3 FEET OF COVER OR LOCATED UNDER PAVEMENT, DRIVES, OR } PROPOSED ; ry 10" 0 l; ' i . I t EVALUATOR. John L. Churchill, PE CSE Tt ,l. L,_ % I �1 • ° TRAVELED WAYS 1N WHICH CASE THEY SHALL WITHSTAND H-20 LOADING. I DISTRIBUTION /' -* ,r t , r ' -✓ / %J f: = • C.S.E. APPROVAL DATE: Nov. 1997 r� BOX 13, DOUBLE WASHED CRUSHED STONE SHALL BE FREE OF ALL DIRT, DUST AND FINES. t -� _,, -` `` . • jj '� _ i June 7, 2017 } 'DATE: 9x3_ F7,, (`,49x2 E d is _/ i _ ._ / S85° 2 ' " , I �` �- P -`; - TEST PIT #: 1 114. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL LOAM, SUBSOIL AND UNSUITABLE •- i s j� 4 9x2' 4 20 E ` s -z C; �} ; 4_1 =`' '.� - L.r- { E MATERIAL IN AREA BENEATH AND FOR 5 FT. ON ALL SIDES OF LEACHING FACILITY. 103.70 r/ �" ELEV TOP = 9.00' REPLACE ALL UNSUITABLE MATERIAL WITH CLEAN COARSE SAND FREE FROM CLAY, 1 PROPOSED zw 1 ,� ,Q c 10.2'.... o �.. _ �.� ( Benchmark yr 4 �`�``"`� ' �.,��' I , : , ` � O � ELEV WATER = 2.33' FINES OR OTHER UNSUITABLE MATERIAL IN ACCORDANCE WITH 310 CMR 15.255(3). INSPECTION PORT .-- ,--9 �? Nall in UP - i ;-. TPI --., .� o \ � _ ? `'�---,..,� ,x ��� �_ � ( _ 15. CONTRACTOR SHALL NOTIFY DESIGN ENGINEER OF ANY DISCREPANCIES FOUND IN .. , r- -;. �. EJ Elev. 8.68 i � � PERC RATE - - t P 2 ,_. O �-" I _-----' SITE CONDITIONS FROM THOSE SHOWN PRIOR TO CONTINUATION OF WORK. 30 °�t NAVD 88 PROPOSED TOTAL ( ) 9x0 _ I .. 9x2 ch .- I DEPTH OF PERC - 16. PROPOSED PROJECT IS LOCATED WITHIN: ARC 36 LEACHING 9x1; a �. 15.1' -'. j i ►.I. ! 1 CHAMBERS IN A FIELD \ \ Q.� „ t- I► -- \ \ \ , �� \ I C7 E �',"✓' i' \ = I TEXTURAL CLASS: 1 ASSESSOR'S MAP: 33 PARCEL: 369.a [ CONFIGURATION � � i � a ��-� .. � � .� � , --_ o i ,.- ; ; LOCUS r � (' ti I i , -) € ) L I OWNER OF RECORD: E$�G�� of �bu�S 4. 134nV�Bb \ • RESERVE � .i l_r . ./' I - t3 i REMOVE AND REPLACE { <<, „ , r y UNSUITABLE MATERIAL TO i` d �,/"� " 1 1 a 3 C SOILS WITH CLEAN 30.0' / COARSE SAND .,� z � ` "tri. ._ I iu MAP 33 io,LOT 367 \ _ N V` ! 'ive-i n rn%�. ---� ' 30" v m s / 30.0' •€ / /eater ( '' O 04 N _ \ 28' o °^o -. I \ i 92„ LOCUS PLAN WSCALE: 1 -1000 120„ 1 � Loamy Sand 10Yr 312 Loamy Sand 10Yr 516 Fine -Medium Sand 2.5Y 714 Mottling 80" 2.5Yr 5/8 -` Standing 92" j ADDRESS: 5 FOUNTAIN STREET 8.50' MILFORD MA 01757 f FEMA FLOOD ZONE AE(EL.11) j I COMMUNITY PANEL # 25001CO589J (dated 7-16-2014) 6.50' 17. DEED REFERENCE: BOOK 1283, PAGE 259 18. PLAN REFERENCE: PLAN BOOK 110, PAGE 53 E� ZONING DISTRICT: R-25 I ZONING REQUIREMENTS PROPOSED MIN. FRONT YARD = 30' 36.2' MIN. SIDE YARD =15' 35.7' 1 2.33' MIN. REAR YARD = 20' 39.2' MAX. LOT COV. (by structures) = 25°% 9°% MAX. LOT COV. (by structures/paving) = 40°% 14% 1.33' MAX. BUILDING HEIGHT = 35' < 35' -1.00' I _ INI 4 j ' I 50x0' EXISTING SPOT GRADE - PROP . � , < osEO I -SIGN - «.- ^` -. z -- - 50 --- / n 4 BEDROOr,q 1DATA 1� t EXISTING CONTOUR MAP 33 tDwELur�G � uT�- -µ� ` : z 50 PROPOSED SPOT GRADE LOT 368 TO = 11.5'± ' _ I �, ( f INSPECTOR: Amy Vonhone ? SLAB = 9.0' I --- / w NUMBER OF BEDROOMS (DESIGN) 4 --, 50 PROPOSED CONTOUR 4 1.' Y .G --8 -l} 1 I DESIGN FLOW 110 GAL/DAY/BEDROOM EVALUATOR: John L. Churchill, PE, CSE , Nov. 1997 x r... �.�..,. n.. C.S.E. APPROVAL DATE: U, , ,. PROPOSED OVERHEAD UTILITIES 0 \ TOTAL DESIGN FLOW 440 GAUDAY I 1LL June 7, 201? E \ I �' DESIGN FLOW x 200 % = 880 GAUDAY DATE: W--------1 PROPOSED WATER LINE 1G" flA!. Ft r ii G USE PROPOSED 1,50 ! TEST PIT #: 2 0 GALLON SEPTIC TANK / La i TEST PIT LOCATION I ELEV TOP = 9.20 I i ELEV WATER = 2.20' 39.2' .._--_-•--- 28' � I Q PROPOSED 1,500 GALLON SEPTIC TANK 10" 0,1,4 C' PERC RATE _ < 2 minrnch / 36.2 INSTALL 30 - ARCI�36 LEACHING CHAMBERS PROPOSED 4" SOLID SCHEDULE 40 PVC PIPE � (SAS effective leaching area = 431 sf > 400 sf mina required - SEE NOTE 2 BELOW) DEPTH OF PERC = 32"-50" j MAP 33 / Lu t ' J PROPOSED DISTRIBUTION BOX I I / '`� 1- Q o SYSTEM CAPACITY LOT 369.01 I TEXTURAL CLASS: 1 • OA!/- 12,662± S.F. i1 j O g (TOTAL L.F. OF CHAMBERS) (4.8 SF/LF) (0.74 GPD/SQ.FT.) = GPD r 20.0' .:�� PROPOSED ARC 36 LEACHING CHAMBER w i (150) (4.8 SFILF) (0.74 GAUSQ.FT.) = 532.8 GAL. LEACHING I DAY I I 0" 9 20' _ LL I A I s I g ! TOTALS: t 8„ TOTAL NUMBER OF CHAMBERS: 30 ( ! E TOTAL NUMBER OF COUPLINGS: 0 B ZONING SETBACKS I % TOTAL LEACHING AREA: 720.0 SQ.FT. -` 13M' �oow �t4,� - ,7 TOTAL LEACHING CAPACITY: 532.8 GAL./DAY 30" o c / 32 co 6 / Perc NOTES: 3 /! N88° 3T 10"W 1.) EFFECTIVE LEACHING AREA OF 4.80 SFILF OBTAINED FROM THE C DEPARTMENT OF ENVIRONMENTAL PROTECTION APPROVAL LETTER r 89.63'=2a y CERTIFICATION FOR GENERAL USE ISSUED TO INFILTRATOR WATER ° 11` OAK / 13*1 PIN117s TECHNOLOGIES, LLC:, DATE OF REVISION: FEBRUARY 19, 2015, 84" {",�i> MODIFIED JUNE 12,2015; TRANSMITTAL NUMBER = X264258. / 1.J NC . . NOTES. 2.) SAS DESIGNED IN ACCORDANCE WITH STANDARD CONDITIONS FOR 94" ALTERNATIVE SOIL ABSORPTION SYSTEMS WITH GENERAL USE Pii 1.) MAGNETIC MARKING TAPE SHALL BE PLACED ALONG THE TOP EDGE CERTIFICATION AND/OR APPROVED FOR REMEDIAL USE ? F P ,;E 24" PI. - `(REVISED: MARCH 2O, ). 2015 / OF EACH SEPTIC SYSTEM COMPONENT. i 120" Loamy Sand 10Yr 3/2 Loamy Sand 10Yr 5/6 Fine -Medium Sand 2.5Y 7/4 Mottling 84" 2.5Yr 5/8 Standin 94" 0 5 10 20 - 40 FEET 2.) CONTRACTOR SHALL VERIFY SOIL CONDITIONS IN THE LOCATION OF y \ THE PROPOSED LEACHING FACILITY TO ENSURE CONSISTENCY WITH --._--.. _ __ ... __.__ _ __I __ Ti";CE L!',iE - \ �-- .�.,_._�.��__�_�._ ______,_n.._.__.-._...._..._.__6..�,.�_,.�-_....._._�._.��.__.- - �...___..�___._...�.. - � oma°�Ac��� PREPARED BY: TEST PIT DATA SHOWN ON THIS PLAN. REPORT TO ENGINEER AND LOCAL RESERVED FOR BOARD OF HEALTH USE I -" � �L JG ENGINEERING, INC. BOARD OF HEALTH IF SOILS ARE NOT CONSISTENT WITH TEST PIT DATA: a CH11 ILL JR - o i 2854 CRANBERRY HIGHWAY I�1,/{ELGO LANE 3.) CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ANY AND ALL �sr'�c ° EAST WAREHAM MA 02538 PLAN s v Co SITE UTILITIES (WHETHER SHOWN OR NOT SHOWN ON THIS PLAN) TO THE ' ,�rs'(PRIVATE WAY) „- PROPOSED DWELLING AND OBTAIN ALL APPLICABLE PERMITS. i 508.273.0377 SCALE. 1 = 10 __ _ `_ Drawn By: SJI Designed By: SJI Checked By: JLC t Job No. 3823 Yarmouth Health Department 8.53' PR N . e Date i 6.70' 1 7/31/17 SJI JLC ADD PROPOSED WATER LINE & MOVE DECK i 6.53' REV. DATE BY APP'D. DESCRIPTION l PROPOSED SITE PLAN I 5.03 PREPARED FOR: I 0 CHU y` ILL JR. SARAJON REALTY LLC 2.20' 0 C " N .41W7 LOCATED AT ° 51 MELGO LANE 1.37' S. YARMOUTH, MA 02664 1 1 SCALE: 1 INCH = X1OFT. DATE: JUNE 23, 2017 !}i� so' 0 5 10 20 - 40 FEET 2.) CONTRACTOR SHALL VERIFY SOIL CONDITIONS IN THE LOCATION OF y \ THE PROPOSED LEACHING FACILITY TO ENSURE CONSISTENCY WITH --._--.. _ __ ... __.__ _ __I __ Ti";CE L!',iE - \ �-- .�.,_._�.��__�_�._ ______,_n.._.__.-._...._..._.__6..�,.�_,.�-_....._._�._.��.__.- - �...___..�___._...�.. - � oma°�Ac��� PREPARED BY: TEST PIT DATA SHOWN ON THIS PLAN. REPORT TO ENGINEER AND LOCAL RESERVED FOR BOARD OF HEALTH USE I -" � �L JG ENGINEERING, INC. BOARD OF HEALTH IF SOILS ARE NOT CONSISTENT WITH TEST PIT DATA: a CH11 ILL JR - o i 2854 CRANBERRY HIGHWAY I�1,/{ELGO LANE 3.) CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ANY AND ALL �sr'�c ° EAST WAREHAM MA 02538 PLAN s v Co SITE UTILITIES (WHETHER SHOWN OR NOT SHOWN ON THIS PLAN) TO THE ' ,�rs'(PRIVATE WAY) „- PROPOSED DWELLING AND OBTAIN ALL APPLICABLE PERMITS. i 508.273.0377 SCALE. 1 = 10 __ _ `_ Drawn By: SJI Designed By: SJI Checked By: JLC t Job No. 3823