Loading...
HomeMy WebLinkAboutEngineered Plan - 2017LEGEND 99- EXISTING CONTOUR X 99 EXIST. SPOT ELEV. -[99]- PROPOSED CONTOUR (98.4] PROPOSED SPOT EL. TH1 SET 4" BELOW rtl TEST HOLE 2� SLOPE OF GROUND MIN. FRONT SETBACK 30' UTILITY POLE [El1.5 FIRE HYDRANT NOTE: NOT ALL SY}BOLS MAY .APPEAR IN DRAWING J SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 4 BEDROOMS @ 110 GPD = 440 GPD USE A 440 GPD DESIGN FLOW SEPTIC TANK: 440 GPD (2) = 880 USE A 1500 GAL. H-10 SEPTIC TANK LEACHING: SIDES 440 GPD (.74) = 595 SF REQUIRED 40' X 15' = 600 SF OK 600 SF X .74 = 444 GPD OK USE A 40' X 15' PIPE AND STONE LEACHING FIELD TES HOLE LOGS ENGINEER: DANIEL E. GONSALVES, SE #13587 WITNESS: PHIL RENAUD DATE: 5/18/17 PERC. RATE _ < 2 MIN/INCH CLASS 1 SOILS ELEV. ELEV. 0» 11.7' 0" 11.7' A LS 18" 1OYR 3/2 B LS 10YR 4/4 34 8.9' PERC C MS 2.5Y 7/4 A LS 10YR 3/2 11" B LS 1OYR 4/4 36 8.7' C MS 2.5Y 7/4 132 I 0.7' 120" I I 1.7' GROUNDWATER ENCOUNTERED AT 112" EL. 2.4 GROUNDWATER ADJ. DATA: WELL: MIW 29 ZONE: A ADJUSTMENT: 1.3' LICE # 17-103 SYSTEM PROFILE (NOT TO SCALE) ACCESS COVERS TO WITHIN 6" OF FIN. GRADE TOP FOUND. EL. 13.8' \ 13.0' MINIMUM .75' OF COVER OVER PRECAST PRECAST H-10 WATERTE�T D'BOX FOR LEVELNESS RISERS (TYP.) MIN. 2' CKNESS 2'o 4"OSCH40 PVC PIPES LEVEL 1ST 2' 11.8* 10" 1500 GAL H-10 14" 11.02 TEE SEPTIC TANK TEE 10.77' ' 0 0 0 0 0 6" MIN SUMP GAS BAFFLE °4°0�°0°°0'0o_°o4 12" MIN. INT. DIM. 9.4' 4' LIQ. LEVEL (ACME OR EQUAL) 9.6' 9.43' • JO,O ••••0*00;0;0;0;0;0;. •` • O 000 O O O0' 0OO 00000000000000000000000000000,00000000o1o„00�000n0o0o n0o00 0 � °0"",l� 6" CRUSHED STONE OR MECHANICAL I COMPACTION. (15.221 [2]) (3.7 % SLOPE) ( % SLOPE)1 ( %SLOPE) FOUNDATION- 21 SEPTIC TANK 117' D' BOX 5' *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL --BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM 40.0' 8.7' 5.0'� LEACHING ADJUSTED GROUNDWATER FACILITY EL. 3.7 NOTES 1. DATUM IS NAVD 88 2. _MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-10 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND MARK CORNERS OF ZONING DISTRICT: RS -40 DISTRICT 1LEACHING 0 oclk FIELD W/ EXISTING PROPOSED: REBAR SET 4" BELOW �o $ MIN. LOT FRONTAGE 150' GRADE INSPECTION PORT MIN. FRONT SETBACK 30' 23.0' [El1.5 2% SLOPE Hi ow t MIN. REARSETBACK 20' FILTER FABRIC -- 14.7' MAX. BUILDING COVERAGE 25% cr, c_ N = TOP 9.73' FINISHED GRADE- 4" LOAM & SEED 7 Lj o - s J o P a CLEAN FILL a 6"DEPTH MIN. pr Uth Shoe 4" PERFORATED PVC 2.5' O.C. S=0.005 - O 3/4"-1-1/2" DOUBLE WASHED ° 8" STONE LEACHING FIELD ° BELOW INV. \ 9 2 LEVEL BOTTOM o 40.0' 8.7' 5.0'� LEACHING ADJUSTED GROUNDWATER FACILITY EL. 3.7 NOTES 1. DATUM IS NAVD 88 2. _MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-10 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. LOCUS MAP 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING LOCUS DIGSAFE (1-888-344-7233) AND VERIFYING THE SCALE 1"=2000'± LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. ASSESSORS MAP 42 PARCEL 55 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED BENEATH AND 5' AROUND THE PROPOSED LOCUS IS WITHIN FEMA FLOOD ZONE X LEACHING FACILITY. _ _ _ _. _- _ ._._._ _- -- (0.2 PCT ANNUAL_ CHANCE FLOOD 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND HAZARD) AS SHOWN ON COMMUNITY REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. PANEL #25001 CO589J DATED 7/16/2014 OWNER OF RECORD JACQUELYN JOHNSON 35 SOUTH STREET SOUTH YARMOUTH, MA 02664 REFERENCES DEED BOOK 7503 PAGE 144 PLAN BOOK 356 PAGE 74 ZONING SUMMARY ZONING DISTRICT: RS -40 DISTRICT 0 oclk REQUIRED: EXISTING PROPOSED: Locu o �o $ MIN. LOT FRONTAGE 150' orni� � MIN. FRONT SETBACK 30' 23.0' 23.0' Ro�tie 2$ Hi ow t MIN. REARSETBACK 20' 113 o 14.7' MAX. BUILDING COVERAGE 25% cr, c_ N = 8.9% Lj o - s J o P a a pr Uth Shoe Nantucket Sound PERMISSION OBTAINED FROM BOARD OF HEALTH. LOCUS MAP 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING LOCUS DIGSAFE (1-888-344-7233) AND VERIFYING THE SCALE 1"=2000'± LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. ASSESSORS MAP 42 PARCEL 55 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED BENEATH AND 5' AROUND THE PROPOSED LOCUS IS WITHIN FEMA FLOOD ZONE X LEACHING FACILITY. _ _ _ _. _- _ ._._._ _- -- (0.2 PCT ANNUAL_ CHANCE FLOOD 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND HAZARD) AS SHOWN ON COMMUNITY REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. PANEL #25001 CO589J DATED 7/16/2014 OWNER OF RECORD JACQUELYN JOHNSON 35 SOUTH STREET SOUTH YARMOUTH, MA 02664 REFERENCES DEED BOOK 7503 PAGE 144 PLAN BOOK 356 PAGE 74 ZONING SUMMARY ZONING DISTRICT: RS -40 DISTRICT REQUIRED: EXISTING PROPOSED: MIN. LOT SIZE 40,000 S.F. 35,865 S.F. 35,865 S.F. MIN. LOT FRONTAGE 150' 202.99' 202.99' MIN. FRONT SETBACK 30' 23.0' 23.0' _. MIN. SIDE -SETBACK 20' 17.5' ; 17.5' .. MIN. REARSETBACK 20' 14.7' 14.7' MAX. BUILDING COVERAGE 25% 6.7% 8.9% �ZH OF MgSs� YF,Y��N OF Mgss DANIEL cSG��o�� DAN I E L A �ctiGu z o A. � OJALA OJAtA `n CIVIL N N0.4098 oNo. 46502 �OFESS\O�nQ �F�G/STe'' qNQ S1IRN ;^ SSS/ONAL DATE DANIEL A. OJALA, P. E., P.L.S. Varmouth.Health Department AN ,VE� 7 �7% :- Qz_ a1ame Date 8 2017 H DEPT, E ,il����� SIT I T L "��� ���� FILA" u 11 OF 3 51%) e� �, f n STREEPET _ U H Y j t0.,_ t M T m -i '_w=?. PREPARED FOR J A C Q U E L Y N J (OD' H IN"S (3 N DATE: JUNE 21, 2017 Scale:1 "= 20' 0 10 20 30 40 50 FEET off 508-362-4541 I fax 508-362-9880 downcope.com down cape engineering, inc. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 17-103