Loading...
HomeMy WebLinkAboutEngineered Plan - 2017SYSTEM PROFILE PROVIDE MIN. 20" DIAM. WATERTIGHT (NOT TO SCALE) MARK CORNERS OF ACCESS COVERS TO WITHIN 6" OF FIN. GRADE LEACHING FIELD W/ PROVIDE INSPECTION PORTS TO REBAR SET 4" BELOW WITHIN 3" OF FINISH GRADE TOP FOUND. EL. 11.1' GRADE 2% SLOPE \ FILTER FABRIC -~ \ MINIMUM .75'10F COVER OVER PRECAST TOP 7.42' 10.0 FINISHED GRADE- 4" LOAM P. SEED OR PAVE AS REQ. PRECAST H-10 RISERS (TYP.) 111 11 (�I I II 11111 1111111- 2*0 8.84 4"0SCH40 PVC CLEAN FILL s" MIN. SUMP PIPES LEVEL 1 ST 2' 12" MIN. INT. DIM. 4' PERFORATED PVC 3' O.C. $=Q,QQj O 10" **EXISTING 14" ° TEE SEPTIC TANK TEE3/4"-1-1/2" DOUBLE WASHED 7.44 $" STONE LEACHING FIELD ° 6"DEPTH MIN BELOW INV 000000000000 WATERTEST D'BOX° 6.90' GAS BAFFLE ::: '°oc°,o°o'o°o? FOR LEVELNESS 7.07, LEVEL BOTTOM ° ' ': 7.29' 7.12' X 99. ' ` •'' 4' LIQ. LEVEL ( ACME :e OR EQUAL) 198-41 PROPOSED SPOT EL. TH 1 6" CRUSHED STONE OR MECHANICAL TEST HOLE 2- SLOPE'OF GROUND COMPACTION. (15.221 [21) UTILITY POLE FIRE HYDRANT - NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING (--!-% SLOPE) (-L-% SLOPE) FOUNDATION— EXIST. SEPTIC TANK 5' D' BOX 5' LEACHING FACILITY *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL **INSTALLER SHALL CONFIRM MINIMUM SEPTIC UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS TANK SIZE AT 1000 GALLONS AND ITS SUITABILITY PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM FOR RE—USE. REPLACE WITH 1500 GALLON LEGEND 99— EXISTING CONTOUR X 99. ' EXIST. SPOT ELEV. —[991— PROPOSED CONTOUR 198-41 PROPOSED SPOT EL. TH 1 _q� TEST HOLE 2- SLOPE'OF GROUND 71) UTILITY POLE FIRE HYDRANT - NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING TEST HOLE LOGS ENGINEER: CRAIG J. FERRARI, SE #13871 WITNESS: AMY VON HONE, RS DATE: 7/27/2017 PERC. RATE < 2 MIN/INCH CLASS i SOILS ELEV. 1 Opt 8.5' A LS 1 OYR 4/2 . 8" B LS 24" 1OYR 5/8 6.5' PERC C MS G—W ADJ. DATA: 1OYR 7/4 WELL: MIW 2.9 ZONE: A ADJ: 1.4' 108" —0.5' GROUNDWATER ENCOUNTERED AT 90" EL. 1.0' DCE #17-219 SEPTIC TANK APPROPRIATE. TO SITE CONDITIONS IF NOT SUITABLE im 6.40' 4.0' 1 ADJUSTED GROUNDWATER 2.4' VARIANCES REQUESTED UNDER TITLE 5 AND YARMOUTH HEALTH REGULATIONS: 1 h: REDUCTION IN GROUNDWATER , SEPARATION, 5' TO 4' 0 10 20 30 40 50 FEET NOTES 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8- PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H -1Q 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE, STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 0 c m d oy P� c 0e� d 0 5 e 3f Locus e Lewis Bay10. CALLINNGTDIGS OE (1-8886344-72BE 0NSIBLE 33) AND LOCUS LOCUS MAP VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF SCALE 1"=2000'± WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL ASSESSORS MAP 30 PARCEL 117 BE REMOVED BENEATH AND 5' AROUND THE LOCUS IS WITHIN FEMA FLOOD ZONE AEEL.11 PROPOSED LEACHING FACILITY. AS SHOWN ON COMMUNITY PANEL ( ) 12. EXISTING LEACHING FACILITY SHALL BE PUMPED #25001 CO569J DATED 7/16/2014 AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 3 BEDROOMS @ 110 GPD = 330 GPD USE A, 330 GPD DESIGN FLOW SEPTIC TANK: 330 GPD (2) = 660 **RE—USE EXISTING 1000 GAL. SEPTIC TANK LEACHING: 330 GPD / (.74) = 446 SF REQUIRED 15' X 30' = 450 SF OK 450 SF X .74 = 333 GPD OK USE A 15' X 30' PIPE AND STONE LEACHING FIELD DECK �y BED Fti GARAGE DEN APPROVED LIVING ROOM BED FLOOR PLANS Permit valid for REPAIR OF SEPTIC SYS•±FAI ONLY; due to State and L,o.cai septic variances. Poard•of health review and alrproval is required tor" any future adcliticinsh-e"(.)+ahons/;ilte.rations to sewage facilities and/or strui tures/cisselling: Ytimouth Health Department L zj Jatet¢ Date DATE , MA DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF #59 WEBSTER ROAD WEST YARMOUTH, MA PREPARED FOR PAUL REA DATE: AUGUST 1, 2017 off 508-362-4541 I fox 508-362-9880 downcope.com down c,&Jbe engineering, inc. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 17-219