HomeMy WebLinkAboutEngineered Plan - 2017�j, ` r 4" SCHEDULE 40 PVC PIPE CLEAN SAND 2" LAYER OF + s E n; + ""'�' , t •' VV V V$ xi TICS I TOP OF FOUNDATION 20 FT. MINIMUM FROM CELLAR OR CRAWL SPACE MIN. PITCH 1 /8" PER FT. WITH STONE INA INSPECTION PORT 1/8" TO 1/2" �, # b t _ } w s DATE OF SOIL TEST JUNE_21j 2017_ _ 100.00 ELEV. - ______ ASSUMED ASSUMED) 10 FT. MINIMUM 10 FT. MINIMUM FROM SLAB 2" PRESSURE PIPE 150 PSI MINIMUM ELEV. = C•P.0 . WASHED STONE 102.58 M X OR FILTER FABRIC VENT SOIL TEST DONE BY SWEETSER ENGINEERING ___-___ WITNESSED BY _A._VON HONE ------ VALVE WASHED STONE CONCRETE _96.50_ MAX. 100.33 MIN. °`'"`"° ""' �- ELEV.= COVERS .,MANHOLE QUICK . 0 S' # A $ # a 1 HOLE � 99.8 COVER DISCONNECT TEE FLOW Z UNION LEVELERS � PERCOLATION RATE ___<2MIN./INCH AT 51 � INCHES . 24" 4" CAST IRON PIPE 6" MAX. 6" MAX. 99'5> a I ALARM ON (OR EQUAL) MINIMUM o 0 0 PITCH 1/4" PER FT. - - LEVOE'L 10" ° PUMP ON 0 ABEL A1800 FILTE 6" SUMP - ° ° ELEV. _ _ 98.25_ 00 rn V) ELEV. = ELEV. = _x•08 PUMP OFF z FLOW LINE -99.25- -- I 9800 10" �. S t �. 3 `�gELEV. = ELEV. = --' --- fMIN. I i A nn 3/HOLERILL 4 HIGH CAPACITY INFILTRATORS z_ 5.06 GAS � � WITH STONE INA ELEV. = BAFFLE TO BE WATER TESTED 11' X 36' X 10" TRENCH FORMATION WELL b11�! 29 _97•00_J ELEV. = 96.75_ o (TO BE PLACED ON FIRM BASE). .� �� g Y n,, t in ZONE B 7.59_ C•P.0 CHECK 3/4" TO 1 1/2" .,_;�3.r.„i INDEX (5/2017) LIQUID OUTLET VALVE WASHED STONE ADJUST 1.89 °Y a" i s' (SAS) DEPTH TEE (TO BE PLACED ON FIRM BASE) 4 FEET 14 INCHES MYERS SRM 4 5 FEET 19 INCHES `� t 0.4 HP (MAX.) �,,� Gr LL. ,,,1 �� p 28-108" 6 FEE? 24 INCHES �.* 1 7 FEET 24 INCHES +'' ° " "I " a r� l „ a�Z � a: ;" (OR EQUAL) ', (C W.11 E USGS PROBABLE .WATER TABLE ELEV. = 93.19 _ OBSERVED WATER TABLE ELEV. = �" F e C 8 FEET 34 INCHES •»` fi (6/21/2017) $� � BOTTOM OF TEST HOLE ELEV.=_g/Ry` 96.50_r y A ;: ELEV. AT INVERT INLET _ ttx t;:ER s>.: €"t g ..;�. 5 .! ;�`, { �`1 E -1 r, > ,dam . 1 x D `v C, `" i I �.:.,' s. ,�°' y l t ELEV. AT ALARM ON - a4.00- �.,.s �:,. ON 3.66_ REQUIRED FLOW PER CYCLE 25 X _ 339 82_5 GAL./CYCLE �... < o f tv,7<:.. n:..4., 1 t . , sbS r.R � t 1 �, ELEV. AT PUMP _ 93.33_ VOLUME PER CYCLE _ 825 GAL/CYCLE /7.48 GAL./CU. FT. = 11_0_3_ CU. FT./CYCLE NOT TO SCALE ELEV. AT PUMP OFF _ 2.5Q VOLUME OF WATER IN PIPE 3.14 X 0.00694 X _ 16FT. _ _a_35 CU. FT. BOTTOM OF INSIDE PUMP CHAMBER _ s2.93_ TOTAL MINIMUM VOLUME PER CYCLE _11.35 CU. FT. BOTTOM OF OUTSIDE PUMP CHAMBER _ DISCHARGE _11_38 CU. FT. / 34,67 CU.FT./FT. = _911 FT. (1000 G.S.T.) STORAGE CAPACITY (-330-_ GAL./DAY /7.48 GAL./CU.FT./34.67 CU.FT./FT. _ 1-27_ FT. -12Z_ REQUIRED _2.A0 PROVIDED 1500 GALLON SEPTIC TANK (MONO) 1000 GALLON PUMP CHAMBER (MONO) WEIGHT OF WATER DISPLACED WEIGHT OF WATER DISPLACED 10.17x6.08x(93.19-92.42)x62.5 2976 LBS. 8.25x5.42x(93.19-92.08)x62.5 3103 LBS. WEIGHT OF TANK PER MANUFACTURER 11833 LBS, WEIGHT OF TANK PER MANUFACTURER 9200 LBS. l WEIGHT OF CONCRETE WEIGHT OF WATER IN SUMP ; EXCESS WEIGHT TO OFFSET FLOTATION WEIGHT OF " CONCRETE r 11833-2976 8,857 LBS. EXCESS WEIGHT TO OFFSET FLOTATION r 9200-3103 6,097 LBS. v LE VE fir. # p EXISTING SPOT ELEVATION 00x0 EXISTING CONTOUR----00---- FjNAL. SPOT ELEVATION _ 7O:O: FINAL CONTOUR HORiZ SOIL TEST LOCATION UTILITY POLE -&_ TOWN WATER =WW 0-5" CATCH BASIN gip) GAS LINE G CLEAN OUT C.O. CESSPOOL C•P.0 1500 GALLON --.• _ -.•t r i✓� SEPTIC TANK I iy rr SLEE 99.8 �k) 00.0 VE _ _ t 4 `I 1� �r•� 98'8 �b � ...� j i Zoi,p 10.0 pp� NTfilS t f y 100, �i� �, rrj z 98.0 Lor 39 i t 6780 f S.F. i SoilTEST PUMP � J�i CHAMBER <, f D. BOX' II 98.1 LIMIT OF 5'� ' <� OVERDIG 98.3 0.4 . 97.6 Per valid for RI',PAIR OF SEP"I'.W.. SYS'l-EIVI ONLY, due to $tate and I .()CAI septic '•yariances. Coard of IIIealth review and approval is required for' any future additions/reoi,vatronsi»iterations to sewage facilities and/or structures/d%%elling. Yarrsotith Hcalth Department > c7-257 ,7 �htne` Date DEPTH HORiZ TEXTURE JCOLCR MOTT. %r 0-5" } FILL NO 5-12" A Per valid for RI',PAIR OF SEP"I'.W.. SYS'l-EIVI ONLY, due to $tate and I .()CAI septic '•yariances. Coard of IIIealth review and approval is required for' any future additions/reoi,vatronsi»iterations to sewage facilities and/or structures/d%%elling. Yarrsotith Hcalth Department > c7-257 ,7 �htne` Date DEPTH HORiZ TEXTURE JCOLCR MOTT. OTHER 0-5" FILL NO 5-12" A LOAMY SAND 10YR5/1 ROOTS 12-28" B LOAMY .SAND 10YR6/6 ROOTS 28-108" C MEDIUM SAND 2.5Y7/4 WATER ENCOUNTERED AT __102" ELEV.. _ _ 91.3-- D NUMBER OF BEDROOMS 3 _ GARBAGE DISPOSAL UNIT _ NO _ TOTAL ESTIMATED FLOW ( 110 GAL/BR./DAY X �_ BR.) Q_ GAL./DAY REQUIRED SEPTIC TANK CAPACITY __NQ_ GAL. ACTUAL SIZE OF SEPTIC TANK _1500- GAL. SOIL CLASSIFICATION DESIGN PERCOLATION RATE <_5, MIN./IN. EFFLUENT LOADING RATE QJA GAL./DAY/S.F.. LEACHING AREA 474_33 SQ. FT. (11 X36)+(47X2X10/12) LEACHING CAPACITY (AREA X RATE) _�_*LDQ GAL./DAY 474.33 X 0.74 RESERVE LEACHING CAPACITY _NWE_ GAL./DAY 1: ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO D.E.P. TITLE 5 AND THE TOWN'S RULES AND REGULATIONS FOR THE SUBSURFACE DISPOSAL OF SEWAGE. 2. ALL COVERS TO SANITARY UNITS SHALL BE BROUGHT TO WITHIN 6" OF FINISHED GRADE. 3- ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF WITHSTANDING H-10. LOADING UNLESS THEY ARE UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS. H-20 LOADING SHALL BE USED UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS. 4. ANY MASONARY UNITS USED TO BRING COVERS TO GRADE SHALL BE MORTARED IN PLACE. 5. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING REGULATIONS. OWNER / APPLICANT IS TO OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY. 6. UTILITIES SHOWN ARE APPROXIMATE ONLY, EXCAVATION CONTRACTOR IS TO CALL "DIG -SAFE" AT 1-888-344-7233 AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE. 7. CONTRACTOR IS TO VERIFY GRADES AND ELEVATIONS AS WELL AS SITE CONDITIONS PRIOR TO COMMENCING WORK ON SITE. ANY VARIATION IS TO BE BROUGHT TO THE ATTENTION OF THE DESIGN ENGINEER. y IMMEDIATELY. 8. PARCEL IS IN FLOOD ZONE --- X--- 9,_LOT_JS. SHOWN ON ASSESSORS _MAP , 3i �..AS PARCEL:.__17$__, - 10. PUMP. AND ALARM ARE TO BE ON SEPERATE CIRCUITS.: 11, ALARM IS TO BE BOTH AUDIO AND VISUAL. 12. A ZABEL A1800 FILTER IS TO BE INSTALLED. 13. AN ELECTRIC PERMIT IS REQUIRED TO WIRE PUMP AND ALARM. 14. ALL UNSUITABLE MATERIAL SHALL BE REMOVED FROM 'UNDER AND FOR A MINIMUM OF 5' AROUND SOIL ABSORPTION SYSTEM AND BE REPLACED WITH MATERIAL 'AS SPECIFIED IN 310 CMR 15.255:(3). 15. SEPTIC TANK AND. PUMP CHAMBER ARE TO BE WATERPROOFED AT THE MANUFACTURER. 16. EXISTING CESSPOOL IS TO BE PUMPED AND BACKFILLED. 17. WASTE LINE FROM HOUSE TO SEPTIC TANK IS TO BE SLEEVED INSIDE 150 PSI PRESSURE PIPE AS SHOWN AT LEFT. 18. VARIANCES TO TITLE 5 AND TOWN REGULATIONS: A. SOIL ABSORPTION SYSTEM LESS THAN 20' FROM FOUNDATION (VAR. OF 5'). B. NO RESERVE AREA. ` 3P@q" RG, 6, 0 t, -