HomeMy WebLinkAboutEngineered Plan - 201714.4' PRECAST H-10 RISERS (TYP.) 2'o *12.0'± 11.55' ., .,.. SYSTEM PROFILE (NOT TO SCALE) PROVIDE MIN. 20" DIAM. WATERTIGHT ACCESS COVERS TO WITHIN 6" OF FIN. GRADE 14.0' MINIMUM .75' OF COVER OVER PRECAST 4"oSCH40 PVC 6" MIN. SUMP PIPES LEVEL 1ST 2' 12" MIN. INT. DIM. 10.. 1500 GAL H-10 14" ILW.- TEE SEPTIC TANK TEE 1 1.30' DDDD°DDODDDD WATERTEST D'BOX GAS BAFFLE ::' °o0�° FOR LEVELNESS +: 4' LIQ. LEVEL (ACME OR EQUAL) 11.19, 11.02' (_2___5% SLOPE) O D O O;.-0;0;0;0;0;0 06060 O D 600 O O O O O 0 0 0 0 0 D�ODO�O 000000 0O DODODAODD00ODODO? D 00 0 c_^ -^D-^_^ 6"D CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 [2]) (-2-% SLOPE) (-1-7. SLOPE) FOUNDATION 18 SEPTIC TANK 5p D' BOX 5' — LEGEND- EGEND99— 99— EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. —[99]— PROPOSED CONTOUR [98.4] PROPOSED SPOT EL. TH 1 TEST HOLE 2YYYY� SLOPE OF GROUND UTILITY POLE FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING TEST HOLE LOGS ENGINEER: CRAIG J. FERRARI, SE #13871 WITNESS: AMY VON HONE, RS DATE: 9/8/2017 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS IN 12" 4 A LS 1OYR 3/2 ELEV. 13.8' B LS 34" 1OYR 5/8 11.0' C PERC FS 1OYR 7/4 *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM G—W ADJ. DATA: WELL: MIW 29 ZONE: A ADJ: 1.5' AUGUST 2017 120" I 13.8' GROUNDWATER ENCOUNTERED AT 120" DICE # 17-298 MARK CORNERS OF LEACHING FIELD W/ REBAR SET 4" BELOW GRADE FILTER FABRIC 14.0 � 11.22' PROVIDE INSPECTION PORTS TO WITHIN 3" OF FINISH GRADE 2% SLOPE FINISHED GRADE– 4" LOAM & SEED OR PAVE AS REQ. CLEAN FILL 4" PERFORATED PVC 3' O.C. S=0.005 0 0 3/4"-1-1/2" DOUBLE WASHED 0 8" STONE LEACHING FIELD 6"DEPTH 010.8' LEVEL BOTTOM o LEACHING FACILITY EM 10.3' 5.0' ADJUSTED GROUNDWATER EL. 5.3' VARIANCES REQUESTED UNDER TITLE 5 AND YARMOUTH HEALTH REGULATIONS: 1b: REDUCTION IN SETBACK, SAS TO FOUNDATION (20' TO 15.9') Sl Scale:1 "= 20' 0 10 20 30 40 50 FEET PORCH NOTES 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-14 I 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) MIN BELOW INV. 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO' SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR LOCUS MAP CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF SCALE 1"=2000'± WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL ASSESSORS MAP 22 PARCEL 113 BE REMOVED BENEATH AND 5' AROUND THE SITE IS NOT LOCATED WITHIN A ZONE II PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. BATH _LIVING (-- KITCHEN ROOM – -- eF0 "00f, FLOOR PLANS NOT TO SCALE Permit valid for REPAIR OF SEP'1'1C SYS I -FM ONLY, due to State and Vocal septic variances. Boaird'of llealth review and a0 proval is required for any future additions/rend%;t tionsialterations to sewage facilities and/or structures/dv,elling. Yurr^Youth Ilealfit Oupas tsuent APPRO "' E D �df& e Date SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 2 BEDROOMS @ 110 GPD = 220 GPD USE A 220 GPD . DESIGN FLOW SEPTIC TANK: 220 GPD (2) = 440 USE A 1500 GAL. SEPTIC TANK LEACHING: 330 GPD / (.74) = 446 SF REQUIRED 15' X 30' = 450 SF OK 450 SF X .74 = 333 GPD OK USE A 15' X 30' PIPE AND STONE LEACHING FIELD , MA APPROVED DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF #20 SILVERLEAF LANE SOUTH YARMOUTH, MA PREPARED FOR CAPE COD SEPTIC/ KALIOUSY m`� �.�� DATE: SEPTEMBER 15, 2017 04', °t' O . f.. ASS - ,' , 5� NIEL DANIELA. r`v- A. OJALA off 508-362-4541 OJALA AI a 4�" CIVIL �, fax 508-362-9880 No. 40.80 No. 46502 � 4p, o �Q7,,a downcape.com esa\ down cape engiaeerin., inc. "vV_r`;,.;.,-may r V civil engineers /and surveyors I 939 Main Street ( Rte 6A) DATE DANIEL A. OJALA, P. E., P.L.S. YARMOUTHPORT MA 02675 17-298