HomeMy WebLinkAboutEngineered Plan - 2017� GO 0 2 �F O D �� Rock RoQQD v I' Locus SCALE 1"=500' i FLOOR PLAN -FIRST FLOOR NOT TO SCALE BATH j BATH BEDROOM BEDROOM+ BEDROOM j BEDROOM FLOOR PLAN --SECOND FLOOF S.A.S. NOTES 1. SOIL ABSORPTION SYSTEM SHALL BE (15) CULTEC 330 XLHD UNITS. USE OF ANY OTHER UNIT REQUIRES A PLAN REVISION AND APPROVAL FROM THE ENGINEER AND TOWN OF YARMOUTH 2. CULTEC ROWS SHALL BE BE SPACED 58" ON CENTER I 3. UNITS SHALL BE COVERED WITH CULTEC 410 FILTER FABRIC AND BACKFILLED WITH CLEAN SAND MEETING TITLE 5 SPECIFICATIONS 4. INSPECTION PORTS SHOWN SHALL BE BROUGHT TO WITHIN 3" OF GRADE. SLOPE TO BE REGRADED SUCH THAT MAXIMUM COVER OVER LEACH FIELD DOES NOT EXCEED 36" 9 Nis �N 5 6t; PROPOSED S.A.S. (15) CULTEC RECHARGER - PROPOSED H-10- 1,500 GALLON SEP11C TANK PROPOSED 6 -OUTLET H-10 DISTRIBUTION BOX / TP -1 1 � 99.53 n NOT TO SCALE �o1b C2 TREELINE EXISTING FENCE E � !� 6x\ // I / G A >� 7�0-�`�,1' W GRASSED AREA LOT 3 56,865 SQ. FT.f G 1.31 ACRES f TOP OF FOUNDATION ELEVATION 100.00 19' OF 4" SCH 40 I PVC, S=0.010 MIN. EXISTING INV.=96.67 INV.=96.48 EXISTING ELECTRIC METER EXISTING _ WATER VALVE E E / W G��O E�APy E W 330 XLHD UNITS r! �`�' ��' " o INSPECTION PORT TO WITHIN 3" OF GRADE (TYP.) r ! 11 l `� ` pF �•'� ,� // o o C' / PSEp / X99 12 / o G 99. i 7k z \ \`�` \\ \�� �� GRASSED o N o �\ l AREA w10, ,l v: l� AREA\ 98.34 X W s` EXISTING SEPTIC S1ZTEM EXISTING \ATO BE REMOVED/AI�ANDUIVED�� \Q8 5�� �' _ �' �- FENCE / (SEE GENERAL. NOIFS) _ J / /r �fT'p�Y ARCA Ill F , /SS / kI i. 1� it / Q1/ EASEMENT 13,242 SQ. FT.± 0.30 ACRES ± ol 110, lk gTF11p Agro PROVIDE ZABEL A1800 FILTER �10" 14" PROPOSED 1,500 GALLON REINFORCED CONCRETE SEPTIC TANK TEE WITH GAS BAFFLE (CENTERED IN TANK OPENING) UPS RISERS ON INLET AND OUTLET OF TANK TO BE BROUGHT TO WITHIN 6" OF GRADE 3' OF 4" SCH 40 PVC• S=0.010 MIN. INV.=96.23 INV.=96.20 RISER ON D -BOX TO BE BROUGHT TO WITHI 6" OF GRADE PROVIDE SPEED LEVELERS ON OUTLETS PIPE TO BE RUN L VEL FOR /- AT LEAST 2 FEET PUT OF THE D -BOX 13' OF 4" SCH 40 (LONGE RUN) j 1! PVC, S=0.005 MIN. INV.=96.03 INV.=95.96 LEVEL STABLE BASE CONSISTING OF 6" CRUSHED STONE PROPOSED 6 -OUTLET DISTRIBUTION BOX INSPECTION PORT ON CHAMBERS TO BE BROUGHT TO WITHIN 3" OF GRADE TO BE GRADED SUCH THAT COVER DOES NOT EXCEED 36" UNITS TO COVERED WITH CULTEC 410 FABRIC AND BACKFILLED WITH CLEAN TITLE 5 SEPTIC SAND ELEV.=96.50 III IR - `h ELEV.=93.96 4.33' X 7.0' CULTEC 330 XLHD 22.5' OVERALL LENGTH PER ROW 6.13' SEPARATION FROM BOTTOM (3)-CULTEC 330 XLHD CHAMBERS PER ROW OF SAS TO BOTTOM OF TESTHOLE NOT 0 PROPOSED PROPOSED PROPOSED OBSERVATIONRHOLES BSERVED DURING SEPTIC TANK DISTRIBUTION BOX SOIL ABSORPTION SYSTEM BOTTOM OF HOLE ELEVATION = 87.83 SYSTEM PROFILE NOT TO SCALE SITE INFORMATION GENERAL NOTES: ADDRESS: 69 UNION STREET 1. THE PROPERTY IS LOCATED IN ZONE X OF THE CURRENT FEMA FLOOD MAP YARMOUTHPORT 2. THERE ARE NO STREAMS OR WETLANDS WITHIN 100 -FEET OF THE PROPOSED SYSTEM. MAP/LOT: 115/59 3. THIS PLAN IS FOR THE DESIGN AND CONSTRUCTION OF THE SUBSURFACE SEWAGE i DISPOSAL SYSTEM ONLY DEED BOOK/PG 23145/48 1 4. VERTICAL DATUM IS ASSUMED PLAN BK/PG 378/59 (LOT 3) 5. INVERT OF BUILDING SEWER SHALL BE VERIFIED PRIOR TO CONSTRUCTION OF THE DESIGN C ALC U LCAT I0 N S SYSTEM DESIGN FLOW 6. ALL CONSTRUCTION MEANS AND METHODS SHALL CONFORM TO 310 CMR 15.00 STATE , REGULATIONS AND LOCAL BOARD OF HEALTH REGULATIONS /0 110 GALLONS/DAY/BEDROOM X 5 BEDROOMS = 550 GALLONS/DAY � 0 7. ALL JOINTS IN THE TANK AND DISTRIBUTION BOX SHALL BE MADE WATERTIGHT TANK CAPACITY THROUGH THE USE OF ASPHALT OR SYNTHETIC POLYMER SEALERS OR HYDRAULIC 200% DAILY FLOW = 1,100 GALLONS; USE 1,500 GALLON TANK CEMENT. u' REQUIRED LEACHING CAPACITY 8. ALL UTILITIES SHOWN ON THIS PLAN ARE APPROXIMATE ONLY AND SHALL BE FIELD VERIFIED. DIGSAFE AND LOCAL UTILITY COMPANIES SHALL BE CONTACTED PRIOR TO o DESIGN PERC RATE = < 2 MIN/INCH ANY EXCAVATION OCCURRING. -'' 550 GPD / 0.74 GALLONS PER DAY PER SQ. FT. = 743.24 SQ. FT. o 9. THE SEPTIC SYSTEM INSTALLER SHALL NOTIFY THE DESIGN ENGINEER 2 DAYS PRIOR 0 0 LEACHING CAPACITY CALCULATIONS TO BEGINNING INSTALLATION OF THE SYSTEM TO ALLOW FOR SCHEDULING OF LOADING CAPACITY/FT. (CULTEC 330) = 7.2 S.F./FT. INSPECTIONS 743.24 S.F. / 7.2 S.F./FT. = 103.23 FT. REQUIRED 10. THE EXISTING TANK SHALL BE BACKFILLED WITH CLEAN FILL AND ABANDONED. THE 3 CHAMBERS/ROW 0 7.0'/CHAMBER + 1.5' LENGTH ADJ./ROW = 22.5' ROW EXISTING LEACH PIT AND DISTRIBUTION BOX SHALL BE PUMPED AND REMOVED. 22.5'/ROW ®5 ROWS = 112.5 FT. PROVIDED Ei. 11. HERE APPLICABLE, UNSUITABLE MATERIAL (A B AND C HORIZONS) ENCOUNTERED I BELOW THE INVERT OF THE INLET TO THE SOIL ABSORPTION SYSTEM, SHALL BE PROVIDED LEACHING CAPACITY = 112.5 FT. X 7.2 S.F./FT. = 810 S.F. 4599 GPD) REMOVED TO A DISTANCE 5' AROUND THE SYSTEM AND BROUGHT BACK TO THE APPROPRIATE ELEVATION WITH CLEAN SAND PER MASSACHUSETTS 310 CMR 15.00 REGULATIONS. 12. NO PRIVATE WATER SUPPLY WELLS EXIST WITHIN 150' OF THE PROPOSED SYSTEM. 13. NO GRAVEL PACKED PUBLIC WATER SUPPLY WELLS OR SURFACE WATER SUPPLY EXIST WITHIN 400' OF THE PROPOSED SYSTEM l 14. THIS DESIGN DOES NOT ALLOW FOR THE USE OF A GARBAGE GRINDER I OF &ksSa r� DATE: AUGUST 23, 2017 PERFORMED BY: ASA MINTZ, PE WITNESSED BY: AMY L. VON HONE, R.S., C.H.O. TP -1 ELEV. 99.50± d 0 000O roti 16" - EXISTING 18" - - -- -104 - - 32" 55" 80" 92" FFILL A SANDY LOAM 1OYR 3/3 B SANDY LOAM 1 10YR 5/6 C 1 SANDY LOAM 10YR 6/6 C2 LOAMY SAND 10YR 6/6 C SILT LOAM 10YR 6/3 C4 MED SAND 10YR 6/5 140" 87.83 MOTTLING: NONE WEEPING: NONE PERC RATE: <2 MIN./IN. SOIL PROFILE 99.50 98.17 98.00 96.83 94.91 92.83 91.83 PERC ® 96" NOT TO SCALE LEGEND TREE BENCH TOP OF FOUNDATION = 100.00 4 CRESTVIEW DRIVE EAST SANDWICH, MA 02537 PHONE: (508) 400-2365 DESIGN.,- LLC Residential Site Design and Permitting PROPERTY LINE - - -104 - - - EXISTING CONTOUR - - -- -104 - - - - PROPOSED CONTOUR x STOCKADE FENCE ELECTRIC SERVICE E W WATE LINE G NATU AL GAS LINE CB � CATCH BASIN HYD FIRE F YDRANT WG �j WATER; GATE VALVE U P -o- UTILITY POLE TREE BENCH TOP OF FOUNDATION = 100.00 4 CRESTVIEW DRIVE EAST SANDWICH, MA 02537 PHONE: (508) 400-2365 DESIGN.,- LLC Residential Site Design and Permitting