HomeMy WebLinkAboutEngineered Plan - Rev. 2017SYSTEM PROFILE (NOT TO SCALE) ACCESS COVERS TO WITHIN 6" OF FIN. GRADE 2" PEASTONE OR GEOTEXTILE 27,3' FILTER FABRIC OVER STONE 2�1 ►IIAII►II l►I !\C / !N /CD n\irD DDcnecT '* PRECAST H-10 RISERS (TYP.) 2'0 ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. CONCRETE COVERS TO WITHIN 3" GRADE 2% SLOPE REQUIRED OVER SYSTEM WATERTEST D'BOX FOR LEVELNE55 BLOCKS OR MIN. 2" WALL THICKNESS PRECAST RISERS 4"6SCH40 PVC MORTAR ALL INVERT IN 22.8' PIPES LEVEL 1ST 2' (�4• COMPONENTS 1•~ / I ENDS (TMP') [_SIDES23.63' U 10" 1500 GAL H-10 14" f a0000000ve ` oo�00000 '* 24.0' TEE SEPTIC TANK TEE ..; o ®®aa ®��� a000- �aoa ;0000000° 3.75 6" MIN. SUMP °°°°°°° °° ° ° ° ° ° ° °°°°°°°° . MM0MM ®noon aa0000�o� o >°°°°°°°° °°o°$°o°o^o0 12" MIN. INT. DIM. N °o°o°o° 000aoaaoaaa oa�oo�o�000 00000000; GAS BAFFLE ° ° >°o°a°o 0 0 o 0 0, ° ° °°° 000000ao®aa ®®®�®®®®oao .°°°°o°°° 23.07' 22.9' '°°°°°°°° °°°°°°%°' 4' LIQ. LEVEL (ACME OR EQUAL) ° ° °" 0o000000o0o0o0o°00000000000000o0o000000000Ooo �o°00000�o°0„o1olono°000°°0 e, 0o°o°o„o0000000, 3/4"-1-1/2" DOUBLE WASHED STONE 4' MIN. H-20 500 GAL. LEACHING CHAMBERS BY ACME PRECAST OR ALL AROUND PRECAST STRUCTURES (3) UNITS REQUIRED 6" CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 33.50' X 12.83' COMPACTION. (15.221 [2]) (3_5 % SLOPE) MIN. (-L% % SLOPE) (--L-% % SLOPE) FOUNDATION SEPTIC SEPTIC TANK 34' D' BOX 12' LEACHING ADJUSTED GROUNDWATER FACILITY r-1 1 r R *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM LEGEN D 99- EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. -[99]-- PROPOSED CONTOUR (98.4] PROPOSED SPOT EL. TH1 Locus TEST HOLE I% SLOPE OF GROUND CQ_) UTILITY POLE Y, FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING TEST HOLE LOGS ENGINEER: DANIEL E. GONSALVES, SE #13587 WITNESS: AMY VON HONE, RS DATE: 8/16/17 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS ELEV. ELEV. 0» 26.5' 0" 26.5' A A LS LS 14" 1OYR 4/1 7" 1OYR 4/1 B B LS LS 1OYR 5/6 1OYR 5/6 28" 24.2' 30" 24.0' PERC C I I C M/FS I I M/FS 2.5Y 6/4 I I 2.5Y 6/4 144" I 114.5' 138" I 115.0' GROUNDWATER ENCOUNTERED AT 138" EL. 15.0 DCS' #' 7-253 G -W ADJ. DATA: WELL: AIW 230 ZONE: B ADJ: 0.8' Scale: • 10 20 30 40 50 FEI Po ND Ln NOTES 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS EXISTING I 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-] 0 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WI TH 31& CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR USMA /r, A CALLING DIGSAFE (1-888-344-7233) AND LOCV VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF SCALE 1"=2000'± WORK. ASSESSORS MAP 77 PARCEL 44 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED BENEATH AND 5' AROUND THE SITE IS LOCATED WITHIN A ZONE II PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN - SAND. SYSTEM DESIGN: I GARBAGE DISPOSER IS NOT ALLOWED EXISTING 4 BEDROOM DWELLING DESIGN FLOW: 4 BEDROOMS 0 110 GPD = 440 GPD USE A 440 GPD DESIGN FLOW SEPTIC TANK: 440 GPD (2) = 880 USE A 1500 GAL. SEPTIC TANK LEACHING: SIDES: 2 (33.5 + 12.8) 2 (.74) = 137 GPD BOTTOM 33.5 x 12.8 (.74) = 317 GPD j TOTAL: 614 S. F. 454 GPD USE (3) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE ALL AROUND Yarmouth Health Department "awe Date �;? N OF N Maw . xa OF M SS ase i�Y/c 9�q\- /off, s�G DANIEL DANIELA. A. Ti �o OJALA 4 OJALA i 06502 A No. 409x80 c j� P I� o DATE DANIEL A. OJALA, P.E., P.L.S. APPROVED DATE BOARD OF HEALTH MA TITLE 5 SITE PLAN OF 106 CAPTAIN SMALL ROAD SOUTH YARMOUTH, MA PREPARED FOR QUINN'S EXCAVATION DATE: AUGUST 17, 2017 REV: AUGUST 31, 2017 (DESIGN FLOW) off 508-362-4541 I fax 508-362-9880 downcape.com d0Wn cape engineering, inc. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 17-253 QUINN'S EXCAVATION.DWG s� o,. 0/d Townhouse Rd. o Woin9 L� X00 0� m Locus ind bmm sro� L. 07 Copt. smoll o t. Bess Q ^- n `� Q_Hazelmoor cu o � C 0 3 p t Noyes roo Wi OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR USMA /r, A CALLING DIGSAFE (1-888-344-7233) AND LOCV VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF SCALE 1"=2000'± WORK. ASSESSORS MAP 77 PARCEL 44 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED BENEATH AND 5' AROUND THE SITE IS LOCATED WITHIN A ZONE II PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN - SAND. SYSTEM DESIGN: I GARBAGE DISPOSER IS NOT ALLOWED EXISTING 4 BEDROOM DWELLING DESIGN FLOW: 4 BEDROOMS 0 110 GPD = 440 GPD USE A 440 GPD DESIGN FLOW SEPTIC TANK: 440 GPD (2) = 880 USE A 1500 GAL. SEPTIC TANK LEACHING: SIDES: 2 (33.5 + 12.8) 2 (.74) = 137 GPD BOTTOM 33.5 x 12.8 (.74) = 317 GPD j TOTAL: 614 S. F. 454 GPD USE (3) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE ALL AROUND Yarmouth Health Department "awe Date �;? N OF N Maw . xa OF M SS ase i�Y/c 9�q\- /off, s�G DANIEL DANIELA. A. Ti �o OJALA 4 OJALA i 06502 A No. 409x80 c j� P I� o DATE DANIEL A. OJALA, P.E., P.L.S. APPROVED DATE BOARD OF HEALTH MA TITLE 5 SITE PLAN OF 106 CAPTAIN SMALL ROAD SOUTH YARMOUTH, MA PREPARED FOR QUINN'S EXCAVATION DATE: AUGUST 17, 2017 REV: AUGUST 31, 2017 (DESIGN FLOW) off 508-362-4541 I fax 508-362-9880 downcape.com d0Wn cape engineering, inc. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 17-253 QUINN'S EXCAVATION.DWG