Loading...
HomeMy WebLinkAboutEngineered Plan - Rev. 2017LEGEND N �yti ° - 100 -- -EXISTING CONTOUR LOCUS �� x 100.98 EXISTING SPOT GRADE 0 -W EXISTING WATER SERVICE o°o of �o -G EXISTING GAS SERVICE �sr �o �\Go STREET B.H. bid--OVERHEAD WIRES _'09 o TEST PIT �o 0 BENCHMARK 28 oboe ROv�E X330„ LOCUS MAP vQ 106 �), E NOT TO SCALE v x 96.65 0 x 96.50 7 L x 97,23 0.00 00 T x 97,6 0 0 0 W LOT 275 \ 18,995 ±SF 0,00 MAP ID: 59-23 0 �.., FL1 x 96.71 x 96.18 0 0 \ CONVENTIONAL .A. \ FOR ILLUSTRATION ONLY-DO NOT INSTALL 2-500 GALLON CHAMBERS W/4' STONE 0 96.56 12.8' x 25.0 S.A.S. FOOTPRINT SHED+ BOTTOM SIDEWALL TOTAL Z �`' AREA AREA AREA j 1 320 SF 151 SF 471 SF `c�r� I p TOTAL CAPACITY = 0.74 GPD/SF(471 SF) } c,� co ) = 348 GPD W /97.16 v'-_ / z ( x 97.0 -- - -- -- Y _ 96,71 / + _ x 97,02 g i 97,l(;, x 97.2 + 97.1 96.41Ple P_e mit valid for REPAIR OF SEPTIC SYSTEM _ __\ Y, due to State and V. ►I Septic variances. PATIO _ x of llealP-feview and approval is required for 97.13x / - a� future additions/renok"ations/alterations to 9 09 x h PATIO 1 se ge,tac lities and/or structures/tIv-11ing: x� 1013 98,02; / 1 arotouth Health 11.)epartme.nt O I 97,41 I APPROVP�'f��q EXISTING / x HOUSE(#6)) GARAGE )I T. 0. F. =101.6E 96.71 e Date x / _ /98'97 ,i BM PATIO _' ;.' 100'3O/�- - BENCHMARK INSTALL 40 MIL POLY LINER / < 100,68 : ` CORNER OF CONCRETE TOP OF LINER, EL.=96.5 j _ 1 LANDING EL.=100.68 100. 6 x BOTT. OF LINER, EL.=94.0 / x 1 10 '. '" 100.59 VENT �T-i---i- - 97.83 OROS EXISTING SEPTIC TANK - -- c� :`p'. 100.34/ W TOP OF TANK, EL.=98.61 I:._ S. - LAMP " 99.67 :. s- :.,.: :. INV. OUT i -97.25E INSPECTION -1- I _ Q ..... ST NE_.: PORT <` , EXISTING S.A.S. �.. S,_:'. o D IVE BE REMOVED STEP DRIVEWAY TO 1 `�:• -.: , ::.. \ :. .. :..� TO I , BACK BY 7 FT. DRIVE_ _ 100,00' (SEE NOTE 11, SHEET 2) UP`9_8144:..;:::... x 99,27 S 53'25'45" W 99, 1 •.100.20.:'-.. 100.12 _ EDGE OF PAVEMENT • 99.92 98,23 99.50 99.72 PK SET 100.00 COPPERBROOK ROAD PLAN REVISION 8/17/17 1) REVISE S.A.S. TO INFILTRATORS 2) CORRECTION TO "B/C" HORIZON OF Mgss9�yG ELEVATION ON SOIL LOG o PETER T. �, PROPOSED SEPTIC SYSTEM UPGRADE PLAN McENTEE CIVIL N f COPPER BROOK ROAD, SO. YARMOUTH, MA 0 .35109 Prepared for: DiBuono Sewer & Drain, 35 Content Lane, Cotuit, MA 02635 F OWNER OF RECORD Engineering by: SCALE DRAWN JOB. NO. y SUROZENSKI ANTHONY R Engineering Works, Inc. 1 "=20' P.T.M. 210-17 OALICE L 6 COPPER BROOK ROAD 12 West Crossfield Road, Forestdale, MA 02644 DATE CHECKED SHEET NO. 6 C SOUTH YARMOUTH, MA 02664 (508) 477-5313 7/30/17 P.T.M. 1 0f 2 NOTE: TO PREVENT BREAKOUT, INSTALL A 40 MIL POLY LINER AS SHOWN ON SHEET 1. TOP OF LINER, EL.=96.5 SEPTIC TANK PROPOSED D -BOX BOTTOM OF LINER, EL.=94.0 INSTALL RISERS & COVERS OVER INLET & INSTALL RISER & COVER PROPOSED S.A.S. OUTLET AND SET TO 6" OF FINISH GRADE SET TO 6" OF GRADE INSTALL INSPECTION PORT OVER ONE ROW(MIN.) T.O.F.=101.6± F.G. EL=100.7± F.G. EL=100.5± F.G. EL.=99.5± F.G. EL.=98.0-.99.3(MAX.) MAINTAIN 2% GRADE MIN. OVER S.A.S. L = 9' L = 8'(MAX) INSPECTION Q S=1% (MIN.) PORT ® S=1% (MIN.) 4'SCH40 PVC 4"SCH40 PVC 6" " 10" I 14" 6 11" TO EXISTING 48" LIQUID INVERT LEVEL ADD INV.=96.67 PROPOSED r 4 ROWS OF 4 UNITS AT 6.25'/UNIT = 25.0' , INV.=96.50 GAS BAFFLE D BOX INV.=97.25± 3 OUTLETS INV.=95.92 (EXISTING -VERIFY) SOIL ABSORPTION SYSTEM (PROFILE) EXISITNG SEPTIC TANK ESTABLISH VEGETATIVE COVER BACKFILL WITH"'aEAN NATIVE OR PERC SAND TO TOP OF CHAMBERS NOTES: BREAKOUT=TOP 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPES & TOP ELEV.=96.33 INVERTS EXITING HOUSE, PRIOR TO INSTALLATION. INV. ELEV.= 95.92 2) D -BOX SHALL BE SET LEVEL AND TRUE TO GRADE BOTTOM ELEV.= 95.00 ON A MECHANICALLY COMPACTED SIX INCH CRUSHED 2 83' STONE BASE, AS SPECIFIED 310 CMR 15.405(2). 4' OF NATURALLY OCCURRING 3) INSTALL INLET & OUTLET TEES AS REQUIRED. PERVIOUS MATERIAL EFFECTIVE WIDTH=11.3' V 4) GAS BAFFLE TO BE INSTALLED ON OUTLET TEE 5' (MIN.) ABOVE G.W. EXISTING SUITABLE AS MANUFACTURED BY TUF-TITE, ZABEL OR EQUAL. BOTTOM OF TEST PIT, EL.=86.0 = MATERIAL USE 4 ROWS OF 4 -HIGH CAPACITY H-20 INFILTRATOR UNITS NO SEPARATION BETWEEN EACH ROW & NO STONE TYPICAL SECTION SEPTIC SYSTEM PROFILE SOIL LOG GENERAL NOTES: 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL DATE OF SOIL EVALUATION: JULY 5, 2017 BOARD OF HEALTH AND THE DESIGN ENGINEER. SOIL EVALUATOR: PETER McENTEE PE(SE#1542) 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS WITNESS: AMY VON HONE R.S. HEALTH AGENT OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE LOCAL RULES AND REGULATIONS, EXCEPT AS REQUESTED BELOW: ELEV. TP DEPTH 310 CMR 15.405(1)(b) CONTENTS OF LOCAL UPGRADE APPROVEL O„ 1) A 6' variance, S.A.S. to cellar wall, for a 14' setback. 98.0 q 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR LOAMY SAND 1OYR 4/2 TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE 97.4 7„ DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING LOAMY SAND FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN95 3 1OYR 5/6 ENGINEER BEFORE CONSTRUCTION CONTINUES. 33" 5. ALL ELEVATIONS BASED ON AN ASSUMED DATUM. C1 PERC 31 "/49" 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF MED. SAND HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 2.5Y 6/4 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. 8. THERE ARE NO WELLS WITHIN 100' OF THE PROPOSED S.A.S. 9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS 87.0 132" C2 AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE FINE DIRECTED BY THE APPROVING AUTHORITIES. SANDY LOAM 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY10YR 5/3 86.0 144" THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. PERC RATE < 2 MIN./INCH 11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS NO GROUNDWATER ENCOANTERED IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3). 12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE INSPECTED BY DESIGN ENGINEER PRIOR TO BACKFILL. 13. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY ANDNOT f.-o'.�OO CONSIDERED TO BE A PROPERTY LINE SURVEY. 0 0 0 0 0 0 0 0 14. THE ENGINEER IS NOT RESPONSIBLE FOR ANY UNDOCUMENTED SEPTIC SYSTEM COMPONENTS NOT SHOWN ON THE PLAN 15. THE SUBJECT SITE DOES NOT LIE WITHIN A STATE REGULATED ZONE II. Closed End Plate Open End Plate SYSTEM COMPONENTS NOT SHOWN ON THE PLAN W ?-- DESIGN CRITERIA 16 1111111111 11111111. - NUMBER OF BEDROOMS: 2 BEDROOMS .................. �75"-I I-34"�I 3 SOIL TEXTURAL CLASS: CLASS I (LOADING RATE=0.74 GPD/SF) 1.25" Side View End View DESIGN PERCOLATION RATE: <2 MIN/IN DAILY FLOW: 220 GPD HIGH CAPACITY INFILTRATORS, H-20 LOADING DESIGN FLOW: 330 GPD INFILTRATOR CHAMBERS GARBAGE GRINDER: NO -not allowed with design LEACHING AREA REQUIRED: (330 GPD) = 445.9 SF N.T.S. .74 GPD/SF PROPOSED SEPTIC SYSTEM UPGRADE PLAN EXISTING SEPTIC TANK: 1000 GALLON CAPACITY DISTRIBUTION 4 OUTLETS (MINIMUM) 6 COPPER BROOK ROAD, SO. YARMOUTH, MA USE 4 ROWS OFF 4 HIGH CAPACITY INFILTRATOR Prepared for: DiBuono Sewer & Drain, 35 Content Lane, Cotuit, MA 02635 H-20 UNITS IN STONELESS BED CONFIGURATION SIDEWALL AREA: NOT APPLICABLEEngineering by: SCALE DRAWN JOB. NO. BOTTOM AREA: (GENERAL USE APPROVAL FOR 4.73 SF/LF) Engineering Works, Inc. N.T.S. P.T.M. 210-17 (INFILTRATORS) 16 UNITS x 6.25 LF x 4.73 SF/LF = 473.0 SF 12 Wlest Crossfield Road, Forestdale, MA 02644 SHEET NO. DATE CHECKED DESIGN FLOW PROVIDED: 0.74 GPD/SF(473.0 SF) = 350.0 GPD (508)1 477-5313 7/30/17 P.T.M. 2 Of 2