Loading...
HomeMy WebLinkAboutEngineered Plan - 2017LOCATION MAP LOT 6 (45,414 SF) 33.5' ASSESSORS MAP: 122 PARCEL: 33 PLAN BOOK: 433, PAGE: 55 LEACH AREA DETAIL SEPTIC SYSTEM DESIGN SEPTIC SYSTEM SECTION H.D.C.I. COVERS -\ FLOW ESTIMATE: TO GRADE COVERS WITHIN 6" - 4 BEDROOMS AT 110 GAL / DAY = 440 GAL / DAY N 102.46 OF FINISHED GRADE SEPTIC TANK: L 440 GAL / DAY _x2 DAYS = 880 GAL USE 1500 GALLON SEPTIC TANK 98.86 & 99.07 11 ELEV. r LEACHING AREA: USE 3 - 500 GALLON CHAMBERS (8.5'x 4.8'x 2' EFF. DEPTH) WITH 4' OF STONE ALL AROUND (33.5'x 12.8'x 2' DEEP) SIDE AREA: (33.5' + 12.8') x 2 x 2 = 185 SF (0.74) = 137 GAUDAY BOTTOM AREA: 33.5'x 12.8'= 429 SF (0.74) =.3l 7 GAUDAY CAPACITY = 454 GAUDAY N w KEY: room ELEV. bedybathroom EXISTING CONTOUR: - - - - LOAMY SAND 36" 10YR 5/8 PROPOSED CONTOUR: ............. CDM EXISTING SPOT ELEVATION: 25.5 2nd FLOOR O N C2 HORIZON PROPOSED SPOT ELEVATION: 25.5 SILT LOAM 120" z TEST HOLE: UTILITY POLE:FENCE 86 T�A 168" 2.5Y 7/4 C1 HOR12 ON LINE: SILT LOAM HYDRANT: �- N RETAINING WALL: BANDS S ND 41 84 120" � � LOCATION MAP LOT 6 (45,414 SF) 33.5' ASSESSORS MAP: 122 PARCEL: 33 PLAN BOOK: 433, PAGE: 55 LEACH AREA DETAIL SEPTIC SYSTEM DESIGN SEPTIC SYSTEM SECTION H.D.C.I. COVERS -\ FLOW ESTIMATE: TO GRADE COVERS WITHIN 6" - 4 BEDROOMS AT 110 GAL / DAY = 440 GAL / DAY N 102.46 OF FINISHED GRADE SEPTIC TANK: L 440 GAL / DAY _x2 DAYS = 880 GAL USE 1500 GALLON SEPTIC TANK 98.86 & 99.07 11 ELEV. r LEACHING AREA: USE 3 - 500 GALLON CHAMBERS (8.5'x 4.8'x 2' EFF. DEPTH) WITH 4' OF STONE ALL AROUND (33.5'x 12.8'x 2' DEEP) SIDE AREA: (33.5' + 12.8') x 2 x 2 = 185 SF (0.74) = 137 GAUDAY BOTTOM AREA: 33.5'x 12.8'= 429 SF (0.74) =.3l 7 GAUDAY CAPACITY = 454 GAUDAY N w SANDY LOAM room ELEV. bedybathroom 0 fV F LOAMY SAND 36" 10YR 5/8 93.5 CDM 50" 2nd FLOOR O N C2 HORIZON LOAMY S SILT LOAM 120" z 93.7 34" 86 MEDIUM SAND 168" 2.5Y 7/4 C1 HOR12 ON SILT LOAM / 88 2.5Y 6/4 BANDS S ND 84 120" � � 85.0 C2 HORI ON 84- / / 92 J i / / J N 40 MIL POLY LINER r 94 o7�,3' 0" 57'x 2' DEEP TOP OF LINER = 91.0 i BOTTOM ELEVATION = 89.0 / I 86 - / r Zb -- th-1 24" (L�) i % \� ` - %J tree l i v) 90 - GARDEN AREA BENCHMARK AT TOP 92' �cp�/ OF PVC CLEANOUT i f ELEVATION = 98.11 ' ,% *th-2^' 94' ; th-3 n c.o. 96 w ^h SH DBARN (open BAR N v CO� M Z 98 7 -98 EXISTING DWELLI 4 SEDROO topnd.=N 046 I _ porch 100 Edge of Pam" end_ M17-52 ROUTE 6A 101.1 100.9 sr / C __100 �O 'tip 3 N GRAVEL DRIVE co U�� BENCHMARK AT NAIL IN POLE ELEVATION = 102.44 (AT CLEAN -OUTS) TION :1111120 1500 GAL SEPTIC TANK (6" OF STONE UNDER OR MMECHANICALLY COMPACTED) TEE SIZES: INLET: 6" UP, 13" DOWN OUTLET: 6" UP, 14" DOWN FINISHED GRADE T MAX. COVER (1' MIN) EV. 92.0 u 81.83 ELEV, D -BOX ELEV. (6' OF STONE UNDER OR MECHANICALLY COMPACTED) -GAS BAFFLE AT OUTLET TEE bed TEST HOLE LOGS room ENGINEER: THOMAS McLELLAN, P.E. jc� CI WITNESS: AMY VON HONE, R.S. �o Fat- DATE: 8-30-17 W - PERCOLATION RATE: <2 MIN/IN Yarmouth Healflh Department 'P "VELD N »e Date kitchen dining room bath living bed area room living area foyer 1 st FLOOR 1porch i EXISTING FLOOR PLAN ELEV. TH-1 bed SANDY LOAM room ELEV. bedybathroom AM LOAMY SAND 36" 10YR 5/8 93.5 familyroom 50" 2nd FLOOR LOAMY SAND C2 HORIZON kitchen dining room bath living bed area room living area foyer 1 st FLOOR 1porch i EXISTING FLOOR PLAN ELEV. TH-1 A HORIZON SANDY LOAM 15" 10YR 4/2 ELEV. B HORIZON AM LOAMY SAND 36" 10YR 5/8 93.5 C1 HORIZON MEDIUM SAND 50" 2.5Y 7/4 LOAMY SAND C2 HORIZON LOAMY S SILT LOAM 120" 2.5Y 6/4 93.7 34" C3 HORIZON MEDIUM SAND 168" 2.5Y 7/4 92.0 2" PEASTONE OR FILER FABRIC - 3/4" - 1 1/2" DOUBL WASHED STONE INSPECTION P_h T i ELEV: 91.0 IMI d ° ° I'l1 88.17 <--> ELEV. 33.5'x 12.8' 3 - 500 GALLON CHAMBERS WITH 4' OF STONE ALL AROUND (33.5'x 12.8'x 2' DEEP) TH-2 96.0 TH- 95.0 A HORIZON ELEV. A HORIZC N ELEV. SANDY LOAM SANDY L AM 10YR 4/2 95.3 18" 10YR 4/2 93.5 B HORIZON B HbRIZC N LOAMY SAND LOAMY S kND 10YR 5/8 93.7 34" 10YR 5/8 92,2 C1 HORIZON C1 HOR12 ON SILT LOAM SILT LOA 2.5Y 6/4 BANDS S ND 2.5Y 6/4 120" 85.0 C2 HORI ON MEDIUM AND 2.5Y 7/4 0 132-1 85.0 156" NO GROUND WATER ENCOUNTERED NOTES: 1. VERTICAL DATUM: ASSUMED 2. MUNICAPAL WATER IS AVAILABLE. 3. SCHEDULE 40 - 4" PVC PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM. _ '4. ALL PRECAST UNITS SUBJECT TO TRAFFIC LOADS TO CONFORM WITH AASHTO H-20 SPECIR CATIONS. barn 5. PIPE PITCH = 1/4" PER FOOT (UNLESS NOTED OTHERWISE). 6. FIRST 2' OF PIPE OUT OF D -BOX TO BE SET LEVEL. 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARBAGE I ISPOSAL. 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE STATE OF MASS. ENVI RONMENTAL CODE (TITLE FIVE) AND LOCAL HEALTH REGULATIONS. 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. 10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT TO EXCEED T WITHOUT VA ZIANCE. 11. FIELD SURVEY PROVIDED BY TERRY A. WARNER, P.L.S., HARWICH, MA. 12. THIS PLAN REQUIRES THE REVIEW AND APPROVAL OF ONE OR MORE TOWN DEPARTMENT AND IS SUBJECT TO CHANGE UNTIL SUCH TIME. 13. EXISTING CESS POOL AND LEACH PIT ARE TO BE PUMPED AND FILLED WITH SAND OR REMOVED, 14. D -BOX TO BE WATER TESTED TO ENSURE LEVELNESS AND EQUAL FLOW. 15. ALL UNSUITABLE SOIL, (SILT LOAM, APPROX. 120" DEEP) WITHIN 5' OF PROPOSED LEACH AEA IS TO BE REMOVED AND REPLACED WITH CLEAN MEDIUM SAND. 16. PROPOSED SEWER LINE TO BE ENCASED WITHIN A PIECE OF 6" PVC PIPE WHEN WITHIN 10' OF EXISTING WATER SERVICE. t. .w tf EY fi_F l r� � • 7. �.� aI � yah tr. ,6 L-40MTS J. McLE • AN, P.E. SITE PLAN LOCATION: 138 ROUTE 6A, YARMOUTHPO PREPARED FOR: DAVID SWIFT DATE: 9-18-17 BASS RIVER ENGINEERING P.O. BOX 1163, EAST DENNIS, MA 508-364-9048 1" = 30'