Loading...
HomeMy WebLinkAboutEngineered Plan - 2017KEY: NOU EXISTING CONTOUR: - - - - PROPOSED CONTOUR: •----•------. EXISTING SPOT ELEVATION: 25.5 PROPOSED SPOT ELEVATION: 25.5TEST HOLE: UTILITY POLE:FENCE LINE: RETAINING WALL: I '- LOCUS II LOCATION MAP LOTS 12,13 & 1/2 OF 11 (19,500 SF) ASSESSORS MAP: 42 PARCEL: 85.1 PLAN BOOK: 91, PAGE: 43 7 o, R1 M17-49 GARAGE 32.0' . . .Ij. . .�... '. . . . . . .. . . . LEACH AREA DETAIL LIVING ROOM F1 BED ROOM KITCHEN BATH FAMILY ROOM EXISTING FLOOR PLAN DINING 1st FLOOR bh 101 SEPTIC SYSTEM DESIGN FLOW ESTIMATE: 3 BEDROOMS AT 110 GAL / DAY = 330 GAL / DAY SEPTIC TANK: 330 GAL / DAY x 2 DAYS = 660 GAL USE 1500 GALLON SEPTIC TANK LEACHING AREA: USE 3 FLOWDIFFUSORS WITH 4' OF STONE ALL AROUND 32'x 12'x I V DEEP) SIDE AREA: (32' + 12') x 2 x 11/12 = 81 SF (0.74) = 60 GAL/DAY BOTTOM AREA: 32'x 12'= 384 SF (0.74) = 284 GAUDAY CAPACITY = 344 GAUDAY 2nd FLOOR SEPTIC SYSTEM SECTION 771 101.73 COVERS WITHIN 6" TOP OF FINISHLD GRAE FOUNDATION 99 8 1/8" per ft ELEV. a (2 PIPES) a 1500 GAL 99.43 SEPTIC TANK 7 L., ELEV. a (6" OF STONE UNDER OR OF COMPACTED) TEE SIZES. INLET: 6" UP, 13" DOWN OUTLET: 6" UP, 14" DOWN y T MAX. COVER 1/8" per ft _ (1' MIN) .18 1 /8" per ft EV. - 98.87 98.7 ELEV. D -BOX ELEV. (6" STONE UNDER OR MECHANICALLY COMPACTED) -GAS BAFFLE AT OUTLET TEE ELEV. 2" PEASTONE OR FILTER FABRIC - 3/4" - 1 1/2" DOUBLE WASHED STONE Y INSPECTION PORT � EIV.= 98.93 97.43 4 4 ELEV. 32'x 12' 3 FLOWDIFFUSORS WITH 4.83' 4' OF STONE ALL AROUND (32'x 12'x 11" DEEP) ADJUSTED GROUND WATER ELEVATION = _ 2.6 %_A-Mj RrIING DRIVE �� '"'"_- _ _ .�_ ®' • � -, T\A �..� 100 1479 °47p0u„ E f-. �• BENCHMARK AT 1 \ \ LEFT CORNER OF 100 _ti 0. Vq i E pRIVE BOTTOP.1 SLATE STEP ELEVATION = 101.39 ETON EXIS�RDOM GA�`GE OW f 1101.73 TREE A top 101 ( I j yam` / %'s ) / 0 / 36" oak 101 12" cedar 12" pi 0S' 195.0„ S 797 W °450 0 18" PINE .� o O N- o - 0 '-100 e��as9���WCFAt SSCc 'r 101 TERRY � o` FIslN WELL. MIW-29, ZONE: A, ADJ. (AUG.): 1.6 114" OBSERVED 91.0 ADJUSTED GROUND WATER ELEV.= 92.6 7-Z ` 120,11 GROUND WATER 90.5 Date NOTES: 1. VERTICAL DATUM: ASSUMED 2. MUNICAPAL WATER IS AVAILABLE. 3. SCHEDULE 40 - 4" PVC PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM. 4. ALL PRECAST UNITS SUBJECT TO TRAFFIC LOADS TO CONFORM WITH AASHTO H-20 SPECT ICATIONS. 5. PIPE PITCH = 1/8" PER FOOT (UNLESS NOTED OTHERWISE). 6. FIRST 2' OF PIPE OUT OF D -BOX TO BE SET LEVEL. 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARBAGE DISPOSAL. 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE STATE OF MASS. EN IRONMEN" CODE (TITLE FIVE) AND LOCAL HEALTH REGULATIONS. 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. 10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT TO EXCEED T WITHOUT V RIANCE. 11. FIELD SURVEY PROVIDED BY TERRY A. WARNER, P.L.S., HARWICH, MA. 12. THIS PLAN REQUIRES THE REVIEW AND APPROVAL OF ONE OR MORE TOWN DEPARTMENI S AND IS SUBJECT TO CHANGE UNTIL SUCH TIME. 13. EXISTING CESS POOL IS TO BE PUMPED AND FILLED WITH SAND OR REMOVED. 14. D -BOX TO BE WATER TESTED TO ENSURE LEVELNESS AND EQUAL FLOW. 15. THIS DESIGN NEEDS THE APPROVAL OF THE FOLLOWING VARIANCE FROM TITLE 5: 15.212: LEACH AREA TO BE LESS THAN V ABOVE WATER, (VARIANCE OF 0.17'). ,..�� \ UP W,/ T OMAS J. McLEUIAN, P.E. SITE PLAN LOCATION: PREPARED FOR: CARL ROCKSTROH DATE: 104-17 SQkLE: 1" = 20' BASS RIVER ENGINEERING P.O. BOX 1163, EAST DENNIS, MA 0264 508-364-9048 I_FM TEST HOLE LOGS TH-1 100.5 O/AHORIZON ELEV. Permit valid for REPAIR OF SEPTIC SV. ONLY, dile; to State and I.ueal septic v.ari onees. ENGINEER: THOMAS McLELLAN, P.E. LOAMY SAND 10YR 4/4 Board•of 1lcalth review and approval is reyuir �d for 13" 99.4 WITNESS: AMY VON HONE, R.S. tins/alteration- any future additions/ren+nao to B HORIZON sewage facilities and/or structm es/dwelling. DATE: 9-6-17 LOAMY SAND PERCOLATION RATE: < 2 MIN/IN 24" 10YR 5/8 98.5 Yarmouth Health Department C HORIZON ME 7/4 SAND pERC AT 42" APP RO) 1 � E 1) S GROUND WATER ADJUSTMENT: RrIING DRIVE �� '"'"_- _ _ .�_ ®' • � -, T\A �..� 100 1479 °47p0u„ E f-. �• BENCHMARK AT 1 \ \ LEFT CORNER OF 100 _ti 0. Vq i E pRIVE BOTTOP.1 SLATE STEP ELEVATION = 101.39 ETON EXIS�RDOM GA�`GE OW f 1101.73 TREE A top 101 ( I j yam` / %'s ) / 0 / 36" oak 101 12" cedar 12" pi 0S' 195.0„ S 797 W °450 0 18" PINE .� o O N- o - 0 '-100 e��as9���WCFAt SSCc 'r 101 TERRY � o` FIslN WELL. MIW-29, ZONE: A, ADJ. (AUG.): 1.6 114" OBSERVED 91.0 ADJUSTED GROUND WATER ELEV.= 92.6 7-Z ` 120,11 GROUND WATER 90.5 Date NOTES: 1. VERTICAL DATUM: ASSUMED 2. MUNICAPAL WATER IS AVAILABLE. 3. SCHEDULE 40 - 4" PVC PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM. 4. ALL PRECAST UNITS SUBJECT TO TRAFFIC LOADS TO CONFORM WITH AASHTO H-20 SPECT ICATIONS. 5. PIPE PITCH = 1/8" PER FOOT (UNLESS NOTED OTHERWISE). 6. FIRST 2' OF PIPE OUT OF D -BOX TO BE SET LEVEL. 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARBAGE DISPOSAL. 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE STATE OF MASS. EN IRONMEN" CODE (TITLE FIVE) AND LOCAL HEALTH REGULATIONS. 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. 10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT TO EXCEED T WITHOUT V RIANCE. 11. FIELD SURVEY PROVIDED BY TERRY A. WARNER, P.L.S., HARWICH, MA. 12. THIS PLAN REQUIRES THE REVIEW AND APPROVAL OF ONE OR MORE TOWN DEPARTMENI S AND IS SUBJECT TO CHANGE UNTIL SUCH TIME. 13. EXISTING CESS POOL IS TO BE PUMPED AND FILLED WITH SAND OR REMOVED. 14. D -BOX TO BE WATER TESTED TO ENSURE LEVELNESS AND EQUAL FLOW. 15. THIS DESIGN NEEDS THE APPROVAL OF THE FOLLOWING VARIANCE FROM TITLE 5: 15.212: LEACH AREA TO BE LESS THAN V ABOVE WATER, (VARIANCE OF 0.17'). ,..�� \ UP W,/ T OMAS J. McLEUIAN, P.E. SITE PLAN LOCATION: PREPARED FOR: CARL ROCKSTROH DATE: 104-17 SQkLE: 1" = 20' BASS RIVER ENGINEERING P.O. BOX 1163, EAST DENNIS, MA 0264 508-364-9048