HomeMy WebLinkAboutEngineered Plans - 2017d
CONVENTIONAL S.A.S.
FOR ILLUSTRATION ONLY -DO NOT INSTALL
LEACH FIELD: LENGTH=40', WIDTH=15' CARRIES
BOTTOM AREA ONLY = 600 SF
AL CAPACITY = 0.74 GPD/SF(600 SF) = 444 GPD
x 100.3
,,\
Z 1-x 17' J
98.81 �I
Cn I - oil
Crl rn
S 38'08'45"
165.18'
S7771
HED
99.04 .35
x
99,24 99.31
_c3 .K x 99.01
�TP 98,a + 1 `
j 98.70
3- - -4--4
T _
LANE
LOT 3
31,447± SF
MAP ID: 51-9
LEGEND
x 100.98
mit valid for REPAIR OF SEPTIC
YSf
EXISTING CONTOUR
i.Y, due. to State and Vocal septic
v.arianc s.
NI
rd, of Health review and approval is r
quired t r
'a
ly futureaddetions/rensjVationsialts
tions O
s
iage facilities and/or structures/dwellin
.
Yarmouth Health Departmet
t
x
/
98.474
APPROVED
99.24
98.27
�)
%
me D
e9.25
,,\
Z 1-x 17' J
98.81 �I
Cn I - oil
Crl rn
S 38'08'45"
165.18'
S7771
HED
99.04 .35
x
99,24 99.31
_c3 .K x 99.01
�TP 98,a + 1 `
j 98.70
3- - -4--4
T _
LANE
LOT 3
31,447± SF
MAP ID: 51-9
LEGEND
x 100.98
EXISTING SPOT GRADE
_ __ 99 - -
EXISTING CONTOUR
- 0.j-- W. -
OVERHEAD WIRES
NI
EXISTING WATER SERVICE
EL. =99.13
EXISTING GAS SERVICE
x 98,34 x 98,29
TEST PIT
BENCHMARK
EXISTING LEACH PITS
TO BE PUMPED, FILLED WITH
SAND, OR REMOVED
EXISTING SEPTIC TANK
(TO REMAIN)
TOP OF TANK, EL. = 97.73
INV. (OUT)=96.40--
BENCHMARK-2
OUTSIDE COR./BOTT. STEP
EL. =99.50
Cn
J 9911 J x o 99. 3x �,.. CA
N 96.20 x tJ / M -2
V
I
DECK (no cellar) \ Cn
M 98,66 s
�EXISTING , .\
BENCHMARK -2
SPLIT LEVEL
OUTSIDE COR./BOTT, STEP 9829
HOUSE(#33)
T. O.F.=102.4±
EL. =99.13
x 98,34 x 98,29
98.44
P'
..'
Q
x
/
98.474
98.27
7*N
98,20.,
10
A
v
98.97 x 98.41
o PETER T.
in
99,70
.;
` ":
x
"- 165.00'
McENTEE
CIVIL
99,41
99.08�� N 35'27'55" W
No. 35109
99.71
l
FLOOD ZONE DESIGNATION
NON HAZARD
99.30
• 99,80 AUNT
PK SET
JA NES
,i •
98.40
98.10
g(z_O l-7
OWNER OF RECORD
PAPADOPOLOS, GEORGE P
PAPADOPOLOS, IRENE
33 AUNT JANES ROAD
SO. YARMOUTH, MA 02664
a
a N
o
3? Q1d Mdl� St.
0
0
m
LOCUS
Mornin `°
Drive fi
N
EiR �-ane LOCUS a
pleasant St
LOCUS MAP I
NOT TO SCALE
GENERAL NOTES:
1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL
BOARD OF HEALTH AND THE DESIGN ENGINEER.
2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS
OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE
LOCAL RULES AND REGULATIONS, EXCEPT AS REQUESTED BELOW:
310 CM 5.405(1)(h):
reduction to the required 5' separation betweenimum
seasonal high groundwater and bottom of S.A.S., for separation.
3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR �s
TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE ,
4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING
FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN
ENGINEER BEFORE CONSTRUCTION CONTINUES.
5. ALL ELEVATIONS BASED ON AN ASSUMED DATUM.
6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF
THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF
HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION.
7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE.
8. THERE ARE NO WELLS WITHIN 100' OF THE PROPOSED S.A.S.
9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS
AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE
DIRECTED BY THE APPROVING AUTHORITIES.
10, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY
THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING
CONSTRUCTION.
11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS
IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND
REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3).
12, AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE
INSPECTED BY DESIGN ENGINEER PRIOR TO BACKFILL.
13. SUBJECT SITE DOES NOT LIE WITHIN A STATE REGULATED ZONE II.
14. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND
AS A PROPERTY LINE SURVEY OR FLOOD ELEVATION CERTIFICATION.
PROPOSED SEPTIC SYSTEM UPGRADE PLAN
33 AUNT JANES ROAD, SOUTH YARMOUTH, MA
Prepared for: Irene Papadopolos, 33 Aunt Janes Rd, So. Yarmouth, MA 02664
Engineering by: Survey Review by: SCALE DRAWN JOB. NO.
Engineering Works, Inc. JC Engineering, Inc. 1 "=30' P.T.M. 238-17
12 West Crossfield Road 2854 Cranberry Hwy. DATE CHECKED SHEET N0.
Forestdole, MA 02644 E.Wareham, MA 02538
(508) 477-5313 (508) 273-0377 8/20/17 P.T.M. 1 Of 2
SEPTIC TANK
INSTALL RISERS & COVERS OVER INLET &
OUTLET AND SET TO 6" OF FINISH GRADE
T.O.F./EXISITNG
-F.G. EL.=99.1 ± ---F.G. EL.=99.0±
I1 oI }
14"
EXISITNG 48" LIQUID -
LEVEL
. 1 GAS�BWFLE
EXISTING SEPTIC TANK
NOTES:
1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE
INVERTS, PRIOR TO INSTALLATION.
2) SEPTIC TANK & D -BOX SHALL BE SET LEVEL AND
TRUE TO GRADE ON A MECHANICALLY COMPACTED
SIX INCH CRUSHED STONE BASE, AS SPECIFIED IN
310 CMR 15.221(2).
3) INSTALL INLET & OUTLET TEES AS REQUIRED.
4) GAS BAFFLE TO BE INSTALLED ON OUTLET TEE
AS MANUFACTURED BY TUF-TITE, ZABEL OR EQUAL.
NOTE: TO PREVENT BREAKOUT, THE PROPOSED
FINISH GRADE SHALL NOT BE < EL.96.1
FOR A DISTANCE OF 15' AROUND THE
PERIMETER OF THE S.A.S.
PROPOSED D -BOX PROPOSED S.A.S.
INSTALL RISER & WATERTIGHT INSTALL 1 INSPECTION PORT(MIN.)
COVER SET TO 6" OF GRADE AT END OF S.A.S.
L = 29'
@S=1% (MIN.)
4'SCH40 PVC
F.G. EL.=98.7±
L = 8'
0 S=1% (MIN.)
4"SCH40 PVC
/' 7.13"TO
INVERT
INV.=95.87J PROPOSED INV. --95.70
INV.=96.40 D -BOX
INV.=95.60
BREAKOUT=TOP
TOP ELEV. =96.08
INV. ELEV.=95.60
F.G. EL.=98.7±
MAINTAIN 2% GRADE (MIN.) OVER S.A.S.
INSPECTION PORT
ONE (MIN.)
4 ROWS OF 7 UNITS AT 5.0'/UNIT = 35'
Wel I No •- •► =, -•
ESTABLISH VEGETATIVE COVER
BACKFILL WITH CLEAN NATIVE OR
PERC SAND TO TOP OF CHAMBERS
BOTTOM ELEV.=95.00-1'
4' MIN. OF NATURALLY OCCURRING 2.83'
PERVIOUS MATERIALS EFFECTIVE WIDTH=11.6'
4' MIN. ABOVE HIGH GROUNDWATER
(WITH VARIANCE) (LEAVE 0.1' 'BETWEEN ROWS) EXISTING SUITABLE
HIGH G.W., EL=90.5 - MATERIAL
USE 4 ROWS OF 7 -ADS Arc 36 HD UNITS IN A STONELESS
CONFIGURATION WITH BED DIMENSIONS OF 11.6' x 35.0'
SEPTIC SYSTEM PROFILE TYPICAL SECTION
N.T.S.
DESIGN CRITERIA
NUMBER OF BEDROOMS: 4 BEDROOMS
SOIL TEXTURAL CLASS: CLASS I
DESIGN PERCOLATION RATE: <2 MIN/IN
DAILY FLOW: 440 GPD
DESIGN FLOW: 440 GPD
GARBAGE GRINDER: NO-S.A.S. NOT DESIGNED FOR GARBAGE GRINDER
LEACHING AREA REQUIRED: (440 GPD) = 594.6 SF
.74 GPD/SF
PROPOSED SEPTIC TANK: 1500 GALLON CAPACITY
PROPOSED D -BOX: 1 INLET, 4 OUTLET (MINIMUM), H-10 RATED
USE 4 ROWS OF 7 -ADS_ Arc 36 HD UNITS IN A STONELESS
CONFIGURATION
WITH BED
DIMENSIONS
OF 11.6' x 35.0'
BOTTOM
AREA: (GENERAL
USE APPROVAL FOR 4.80 SF/LF OF UNIT)
(Arc36
Units) 28 UNITS x 5.0
LF x 4.80 SF/LF = 672.0 SF
DESIGN
FLOW PROVIDED:
0.74
GPD/SF(672.0 SF) = 497.3 GPD
NOMINAL AREA OF BED =
11.6'
x 35.0' = 406 SF
SOIL LOG
DATE: AUGUST 9, 2017
11
SOIL EVALUATOR: PETER McENTEE PE(SE#1542)
WITNESS: AMY VON HONE' RS HEALTH AGENT
ELEV. TP DEPTH
98.7 A 0„
9M
93.7
LOAMY SAND
10YR 4/2
8„
B
LOAMY SAND PERC
10YR b/8 20"/38'
30"
Cl
FINE SAND
2.5Y 5/3
60"
C2
MED. SAND
2.5Y 6/4
90.5 ADJ. G.W. -
89.2 STG. G.W. i 114°
89.1 115
STANDING G.W. AT 114" (EL=89'.2), INDEX WELL MIW-29, ZONE A
WATER LEVEL=7.7 (JUY 2017), ADJUSTMENT=1.3'
ESTIMATED HIGH G.W., EL.=90.5
PERC RATE: <2 MIN/IN. ("B/C" HORIZONS)
PROPOSED
a, S.A.S. <v ?
N 9(9.
N ? .8,
N 1tttL -
o
DECK (no cellar)
EXISTING
,SPLIT LEVEL
HOUSE(IM)
T.
S.A.S. LAYOUT
13"
3:
END CAP END CAP
FRONT VIEW SIDE VIEW
END CAP
REAR/TOP VIEW
NOTE: UNIT CONFIGURATION AND AVAILABILITY SUBJECT DIVL VIG\v
TO CHANGE WITHOUT NOTICE. PRODUCT DETAIL MAY
DIFFER SLIGHTLY FROM ACTUAL PRODUCT APPEARANCE.
4640 TRUEMAN BLVD
HILLIARD, OHIO 43026 Arc 36 DETAIL ak
ADVANCED DRAINAGE SYSTEMS. INC. • UNITS MUST BE STAMPED HD
PROPOSED SEPTIC SYSTEM UPGRADE PLAN
33 AUNT JANES ROAD, SOUTH YARMOUTH, MA
Prepared for: Irene Papadopolos, 33 Aunt Janes Rd, So. Yarmouth, MA 02664
Engineering by: Survey Review by: SCALE DRAWN JOB. NO.
Engineering Works, Inc. JC Engineering, Inc. N.T.S. P.T.M. 238-17
12 West Crossfield Road 2854 Cranberry Hwy. DATE CHECKED SHEET N0.
Forestdale, MA 02644 E.Wareham, MA 02538
(508) 477-5313 (508) 273-0377 8/20/17 P.T.M. 2 Of 2