Loading...
HomeMy WebLinkAboutEngineered Plans - 2017SCALE: 1 " = 20' Yarmouth Health Department VED� ,APPff Date EXIST. CESSPOOLS TO BE REMOVED (SEE NOTE 10) GENERAL NOTES: 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE LOCAL RULES AND REGULATIONS. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY PROVIDED BY MUNICIPAL WATER. EXISTING WATER SERVICE TO BE RE -LOCATED AND SLEEVED AS SHOWN. S. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR. 9. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. s O LOT 155/156A O13,503± S.F. (0.31± AC.) kn WEST YARMOUTH PROPOSED CONTOUR 10. EXISTING CESSPOOLS TO BE CRUSHED, PUMPED PROPOSED SPOT GRADE r798LEGEND EXISTING CONTOUR AND REMOVED PER TITLE 5. 11. 48 HOUR NOTICE FOR ENGINEER CERTIFICATION EXISTING SPOT GRADE EXISTING WATER SERVICE 12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY TEST PIT SCALE: 1 " = 20' Yarmouth Health Department VED� ,APPff Date EXIST. CESSPOOLS TO BE REMOVED (SEE NOTE 10) GENERAL NOTES: 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE LOCAL RULES AND REGULATIONS. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY PROVIDED BY MUNICIPAL WATER. EXISTING WATER SERVICE TO BE RE -LOCATED AND SLEEVED AS SHOWN. S. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR. 9. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. s O LOT 155/156A O13,503± S.F. (0.31± AC.) kn PROP. 40m1 POLY LINER (SEE NOTE 18) PROP. 2,000G 2 -COMP TANK G (150OG/500G) 12 10 7.5 7.2 \ TH#1 �. ,44 7.0 v 0-• S ' r"/ I L i 5.Q v0N� ON LOCUS MAP PROP. SOIL LOCUS INFORMATION REMOVAL (SEE NOTE 17) PLAN REF: 020/015 TITLE REF: 30099/223 PARCEL ID: MAP 49 PAR. 232 FLOOD ZONE: "AE11" COMMUNITY PANEL: 25001CO587J DATED:07/16/14 AREA: 0.31 ACRES s PROP. GEOGRID FOOT PRINT (SEE NOTE 19) \ 13.0 G. --1"3 - 1'1 survey by: Weller * A55oc. SEPTIC SYSTEM REPAIR PLAN LOCATED AT: 66 LADE ROAD WEST YARMOUTH, MA PREPARED FOR ANN PETERSON JUNE 12, 2017 of �V o�DAVI ti R' NO. 1140 -Isl �o SgNi TAR\P� c, 1 2-(j 7 MEYER & SONS INC. .P.O. BOX 981 E. SANDWICH, MA 02537 PH. (508)360-3311 fax (774)413-9468 meyerandsonstitle5@gmail.com SHEET 1 OF 2 WEST YARMOUTH 10. EXISTING CESSPOOLS TO BE CRUSHED, PUMPED AND REMOVED PER TITLE 5. 11. 48 HOUR NOTICE FOR ENGINEER CERTIFICATION BUCK J RPS 12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY �qNp AND IS NOT TO BE CONSIDERED A PROPERTY UNE SURVEY ` 13. NO PRIVATE WELLS WITN+N 100 FT. OF PROPOSED LEACHING 14. ALL PIPE TO BE 4' SCH 40 O 1/8'/FT (UNLESS SPEC. OTHERWISE) �U 1 / G 15. THE DESIGN OF THIS, SYSTEM DOES NOT ALLOW �� FOR THE USE OF AGARBAGE GRINDER 16. NO WETLANDS WITHIN ry 100 FT.,.dF PROPOSED LEACHING JUN Z 02017 17. REMOVE UNSUITABLE SOILS/EET AROUND LEACHING TO EL 3.30 �O OR TOP OF C LAYER AND REPLACE WITH CLEAN MEDIUM SAND PER TITLE HEALTH DEP 6 SPK 18. PLACE 40m1 POLY LINER AROUND LEACHING AS SHOWN SWAN ITE FROM ELEVATION 7.0-3.0 19. PLACE GEO-GRID UNDER LEACHING AS SHOWN. POND SWAN PROP. 40m1 POLY LINER (SEE NOTE 18) PROP. 2,000G 2 -COMP TANK G (150OG/500G) 12 10 7.5 7.2 \ TH#1 �. ,44 7.0 v 0-• S ' r"/ I L i 5.Q v0N� ON LOCUS MAP PROP. SOIL LOCUS INFORMATION REMOVAL (SEE NOTE 17) PLAN REF: 020/015 TITLE REF: 30099/223 PARCEL ID: MAP 49 PAR. 232 FLOOD ZONE: "AE11" COMMUNITY PANEL: 25001CO587J DATED:07/16/14 AREA: 0.31 ACRES s PROP. GEOGRID FOOT PRINT (SEE NOTE 19) \ 13.0 G. --1"3 - 1'1 survey by: Weller * A55oc. SEPTIC SYSTEM REPAIR PLAN LOCATED AT: 66 LADE ROAD WEST YARMOUTH, MA PREPARED FOR ANN PETERSON JUNE 12, 2017 of �V o�DAVI ti R' NO. 1140 -Isl �o SgNi TAR\P� c, 1 2-(j 7 MEYER & SONS INC. .P.O. BOX 981 E. SANDWICH, MA 02537 PH. (508)360-3311 fax (774)413-9468 meyerandsonstitle5@gmail.com SHEET 1 OF 2 PROPOSED TANK INSTALL RISERS W/IN 6" OF FINISH GRADE T.O.F. EL.=8.50 EL.7.40t x M� .Y - � N OS=2X (MIN.) INV.= 5.58 Prop. Invert INV.= 6.0 r7-4± EL.6.60 NOTE: MAGNETIC TAPE TO BE PLACED OVER ALL COVERS PUMP CHAMBER D-80 INSTALL RISERS to FINISH GRADE INSTALL RISERS W/IN 6" OF FINISH GRADE FINISH GRADE=8.0-10.0 El. 7.4t F.G. EL: 8.3t � MIN. COVER OVER S.A.S. = 9" MAINTAIN 2% MIN SLOPE OVER LEACHING AREA Lal 0"1 FLOAT TO GP 2000 HIGH WATER ALARM PANAL ON SOOG CIRCUIT SEPARATE FROM CIRCUIT TO THE PUMP. TEE'S RE TO BE MEYER, R.S., COMP. HOISTING CABLE 7x19 STAINLESS STEEL 4" SCH 40 PVC 1,500G GAS PUMP CHAM. COMP. BAFFLE j (SEE DETAIL A w/ FILTER BELOW) PROPOSED 1,500/500 GALLON 2 -COMPARTMENT SEPTIC TANK NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INVERTS PRIOR TO CONSTRUCTION. 2) TANK/PUMP CHAMBER, AND D -BOX SHALL BE SET TRUE TO GRADE ON A MECHANICALLY COMPACTED SIX INCH CRUSHED STONE BASE AS SPECIFIED IN 310 CMR 15.221(2). 3) INSTALL PVC INLET/OUTLET TEES W/GAS BAFFLES IN SEPTIC TANK AS SHOWN. 4) PLUMBING TO BE MODIFIED TO MEET OUTLET ELEVATION AND LOCATIONS AS SHOWN, (PLUMB. PERMIT REQ'D) INSTALL V PVC CONDUIT TO -HOUSE FOR WIRING INSTALL _..-----------_. SWTARY TEE INSTALL TWO INSPECTION PORTS(MIN.) L=12'(MAX) SCH 40 PVC: 4" SCH 40 PVC FORCE MAIN 3.3" TO pol 0 S= 1% (MIN.) y, INV.= 6.50 INVERT- (sm note 18) INV.= 6.70 D -BOX PAGE 1 -INV.= 5.33TEf SHALLNOT EXTEND 4 ROWS OF 6 UNITS AT 4.0'/UNIT = 24.0'/ROW BELOW FLOW UNE INV. EL.=6.38 (USE DB -5 W/BAFFLE) SOIL ABSORPTION SYSTEM (PROFILE) OFs�9� i RESTORE VEGETATIVE COVER Z3` yG BACKFILL WITH CLEAN PERC SAND 1 TO TOP OF CHAMBERS 01 40 \, BREAKOUT=TOP ELEV.=6.77 <. 9 SfEp INV. ELEV.= 6.38 BOTTOM ELEV.= 6.10 PLACE GEO-GRID NITA?, UNDER LEACHING I 5' MIN. ABOVE BOTTOM OF 2 83' ON TOP OF EXIST. MATERIAL SEPTIC SYSTEM ' 'PROFILE T.P. EXCAVATION OR G.W. EFFECTIVE WIDTH = 4 x 2.83' (5.i3' PROVIDED) USE 4 ROWS OF 6 INFILTRATOR QUICK 4 PLUS N.T.S. 1� ADJ. GROUNDWATER EL.=0.97 _ STD LP (3.3" INVERT) UNITS -NO STONE WITH WATERTIGHT JOINTS. WARE HIGH WATER ALARM PROVIDE WATERTIGHT CONCRETE RISER FLOAT TO GP 2000 HIGH WATER ALARM PANAL ON WITH SECURED COVER TO GRADE CIRCUIT SEPARATE FROM CIRCUIT TO THE PUMP. NEMA 4 JUNCTION BOX CORROSION RESISTANT MEYER, R.S., & LIQUID -TIGHT CABLE CONNECTORS SUPPORTED HOISTING CABLE 7x19 STAINLESS STEEL BY 1-1/4" PVC CONDUIT. JOINTS TO BE MADE 1/8" DIAMETER. / 1,760 LB. STRENGTH. TP- 1 WATERTIGHT 5.80 A 2"BALL VALVE W/ UNIONS SCH. 80 PVC PC INV.(OUT)=5.33 GEORGE FISHER CO. MODEL NO. 560 OR EQUAL LOAMY SAND 2"SCH. 40 DISCHARGE TO D -BOX (USE PRESSURE FITTINGS) ALARM ON EL 2.66 1OYR 4/1 2"SCH. 40 TEE W/ CLEAN-OUT CAP PUMP ON EL 2.41 B PROVIDE 1/4" WEEP HOLE IN DISCHARGE PUMP OFF EL 2.08 16 PIPE FOR SELF -DRAINING FORCE MAIN 113" 9' 2" BALL CHECK VALVE SCH. 80 PVC BOTTOM OF INT. P.C. EL. 1.33 100 P.S.I. FLOWMATIC MODEL No. 208S PROVIDE 2- WIDE ANGLE If LOATS• 2" SCH. 40 PVC DISCHARGE PIPE FLOAT NOA: PUMP OFF 7 FLOAT NO.2: ALARMOACTI ATIIONRNES (B RNES618 07 61R2EOR EQUALQUAL) BARNES SEV412 PUMP .5 H.P. 115 V 2" DISCHARGE PASSING 2" SOLIDS OR EQUAL NOTE: SEPTIC TANK AND PUMP CHAMBER TO BE FACTORY WATERPROOFED AND SEALED WITH THOROSEAL OR EQUAL. PUMP & ACCESSORIES AVAILABLE AS A UNIT THROUGH WIGGEN PRECAST CORP., BOURNE MA, (800) 564-6774 PUMP & ACCESSORIES AVAILABLE THROUGH WIWAMSON ELECTRIC (781) 444-6800 PUMP DETAIL N.T. BUOYANCY CALCULATIONS 2.000 2 COMP -SEPTIC TANK yplift: 12' x 7' x 4 x 62.4 = 20,966.4 lbs ground cover. 12' x 7' x .75 x 120 = 7,560 lbs empty tank: 16,000 lbs groundcover + empty tank > uplift: 7,560 + 16,000 = 23,560 lbs > 20,966.4 lbs TANK BUOYANCY CHECK O.K. DOSING & STORAGE REQUIREMENTS DAILY FLOW: 330 GPD DOSING REQUIRED: 8 CYCLES/DAY (SAND) 330 _ 8 = 41.25 GALLONS/CYCLE DISTANCE REQUIRED BETWEEN PUMP ON AND PUMP OFF FLOATS: 41.25 GAL/CYCLE _ 125 GAL/FT = 0.33 FT/CYCLE (4") STORAGE REQUIRED ABOVE WORKING LEVEL: 330 GALLONS STORAGE PROVIDED: INV. EL -4.75 - ALARM ON EL: 2.08 =2.67' STORAGE PROVIDED = 2.67' X 125 GAL/FT = 333.0 GALLONS SOIL LOG DTE: MARCH 2, 2017 SOIL EVALUATOR: DARREN M. MEYER, R.S., WITNESS: A. VONHONE, YARMOUTH I Elev. TP- 1 Depth 5.80 A 0" LOAMY SAND 1OYR 4/1 5.05 B 9» LOAMY SAND 10YR 6/8 3.30 C 30" PERC ® 1.64 MEDIUM SAND 2.5Y 6/4 -1.20 84" PERC RATE <2 MIN/IN. ("Cl- HORIZON) GROUNDWATER OBSERVED AT 70" EL. -0.03 WELL MIW-29, ZONE A, LEVEL 8.4, ADJ 1. USE BOARD OF HEALTH ALL O' ADJUSTED GROUNDWATER Efil _�<w� TYPICAL SECTION DESIGN CRITERIA KTs NUMBER OF BEDROOMS: 3 BEDROOM DESIGN SOIL TEXTURAL CLASS: CLASS I DESIGN PERCOLATION RATE: <2 MIN/IN DAILY FLOW: 330 G.P.D. DESIGN FLOW: 330 G.P.D. GARBAGE GRINDER: NO (NOT DESIGNED FOR GARBAGE GRINDER) SEPTIC TANK/PUMP CHAMBER: 330 gpd x 200% = 660 gpd USE 2 -COMP 2,000G TANK (1,50OG/500G) LEACHING AREA REQUIRED: (330)/0.74 = 445.94 S.F. DISTRIBUTION BOX: (3 OUTLETS (MINIMUM)) PRIMARY S.A.S. USE 4 ROWS OF 6 - INFILTRATOR QUICK 4 STD LP (3.3" INVERT) UNITS WITH NO STONE BOTTOM AREA: (GENERAL USE APPROVAL FOR 4.73 SF/LF OF CHAMBER) (CHAMBER UNITS) 24 UNITS x 4.00 LF x 4.73 SF/LF = 454.08 SF TOTAL AREA = 454.08 SF DESIGN FLOW PROVIDED: 0.74GPD/SF(454.08SF) = 336 GPD > 330 GPD req'd PROPOSED SEPTIC SYSTEM UPGRADE PLAN 66 LAKE ROAD, WEST YARMOUTH, MA Prepared for: Ann Peterson Design and Site Plan by: SCALE DRAWN DATE MEYER& SONS, INC. N.T.S. DMM 06/12/17 8r 4 NDW/CH, M4 02537 EAST SA REV. DATE SHEET NO. EAST 508-3622W 2 of 2