Loading...
HomeMy WebLinkAbout39 Pine Street - Plan of LandACCESS COVERS MUST BE WITHIN 9' Mll'fIMUM. INVERT ELEVATIONS: DESIGN CRI TER IA: - 6' OF FINISH GRADE 3' MAXIMUM COVER INVERT AT BUILDING: 97.0 DESIGN FLOW: 10 0 FIRST 2' TO INVERT /N SEPTIC TANK: 96.0 4 BEDROOMS AT 1/0 G.P.D. PER 1\ BE LEVEL MIN 2' OF PEAS1'ONE INVERT OUT SEPTIC TANK: 95.75 BEDROOM EQUALS 440 G.P.D. 4' DIAM PIPE INVERT IN DIST. BOX: 95.37 97.0 95.75 95.2 T2* ��� 90.5 WASHED STONE INVERT INVERT oN LEACH CUT DIST. H 96.0 92.5 NO GARBAGE GRINDER a� ----� 96.0 ~ eaFFCE 95.37 v GA 5 � 92.5 � H 3-500 GAL LEACHING CHAMBERS 3 OUTLET BOTTOM OF LEACH CHAMBER: 90.5 SEPTIC TANK REQUIRED: ADJUSTED GROUND WATER: N/A 440 G.P.D. X 200x - 880 GAL. D -BOX SEPTIC TANK PROVIDED 1500 GAL. MIN. W/4 ' STONE AROUND. 12. 8 'X 33.5 'X 2 ' tip' �0 ��, , 1500 GAL OBSERVED GROUND WATER: N/A SEPTIC TANK 6' CRUSHED STONE BASE BOTTOM of TEST HOLE of: 84.7 SOIL ABSORPTION SYSTEM REQUIRED: DESIGN PERC RATE f5 MIN/INCH ! �\ SOIL TEXTURAL CLASS - I - PROFILE : NOT To SCALE EFFLUENT LOAD ! NG RATE - 0.74 GPD/SF 440 GPD / 0.74 GPD/SF - 595 S.F. REQUIRED t PROVIDED: 3-500 GAL LEACHING CHAMBERS W/4' STONE AROUND. A-6/4 S.F. /--- t ,— \ \\ \ 60. SOIL TEST PIT DA TA INDICATES�_ INDICATES PERCOLATION OBSERVED TEST GROUNDWATER