IF UNDERMINING OF EXISTING x16' CMU PIER IS IMMINENT
THE PIER MAY BE REM
LALLY COLUMN IS TO BE INSTALLED ON EACH SIDE .
EXISTING
FRS
Scott
EXISTING CMU FND WALL
00
APPROX EDGE OF EXCAVATION y
BACKFILL PIT W/ FLOWABLE FILL W EE O r' o W S
AFTER CONTAMINATION IS REMOVED
PROPOSED 3-1/2' LALLY COU AN
ON A 24'x24'x12' FOOTING 04LY REQUIRED
IF AN ADJACENT PIER IS UNDTMINED. F0071NG
TO BEAR ON CONTAMINATION ME SOIL
_ tEXISTING
B�rrr
EAM J
EXISTING 8'x16' CMU PIER TO REMAIN
I
NEW 7-1/4' LVL ATTACHED TO EACH SIDE OF THE
EXISTING BEAM WITH (2) 4' TIMBERLOK
SCREWS O 12' O.C.
�I
0 c3
ZZ
EXISTING CMU Dim
FOUNDATION WALL
WE
EXISTING CHIMNEY
CONTRACTOR TO AVOID UNDERMINING
t -l'\ STAGE 1; PILE LAYOUT PLAN
SCALE 1/4' = 1'-0'
1. CODE:
MASSACHUSETTS STAGE BUILDING CODE (780 -CMR)
2. DESIGN LOADS;
DEAD
LIVE
10 psf
40 psf
FIRST FLOOR
10 psf
20 psf
ATTIC
1D psf
30 psf
ROOF (GROUND SNOW)
60 pef
-
FOUNDATION WALL
3. DESIGN CRITERIA, CONTRACTOR TO VERIFY;
*8' THICKNESS OF FOUNDATION
*5' MINIMUM HEIGHT OF FOUNDATION WALL
*8' MAXIMUM HEIGHT OF FOUNDATION WALL
*CORES OF CMU BLOCK ARE HOLLOW
CONTRACTOR TO NOTIFY THE ENGINEER IF ANY OF THESE CRITERIA DO NOT MATCH EXISTING
FIELD CONDITIONS.
4. UNFORESEEN CONDITIONS, EXISTING CONDITIONS THAT DO NOT MATCH THE DESIGN CRITERIA,
OR ANYTHING OUT OF THE ORDINARY, MAY REQUIRE A SITE VISIT FROM THE ENGINEER
AT ADDITIONAL COST.
5. PILE LOADS (DRIVEN):
PILE LOADPRESSURE* CAPACITY**
ALL <5.090 Ib 1,600 psi 6,632 Ib
*CONTRACTOR TO USE EARTH CONTACT PRODUCT, 3-1/2'4 X 0.165' DRIVEN PILE INSTALLED
TO A MINIMUM EMBEDMENT OF 10', USING A 'HYD -350 -DC' DRIVER.
"CAPACITY INCLUDES A FACTOR OF SAFETY = 2.0
6. PILE LOADS (HELICAL):
PILE LOADTORQUE* CAPACITY**
ALL 66,027 Ib 1,500 'Ib 6,375 Ib
*CONTRACTOR TO USE EARTH CONTACT PRODUCT, TAH -288-60 10 TORQUE ANCHOR
(2-7/8'0 X 0.262') HELICAL PILE INSTALLED TO A MINIMUM EMBEDMENT OF 10', USING
A 'ESKRIDGE 288' DRIVER.
**CAPACITY INCLUDES A FACTOR OF SAFETY - 2.0
7. PILES ARE TO BE INSTALLED WITHIN 10 DEGREES OF PLUMB, TO A MINIMUM EMBEDMENT
DEPTH OF VY TO THE BEARING POINT OF THE PILE OR THE UPPERMOST HELICAL PLATE.
8. PILE IS NOT INSTALLED UNTIL THE CRITERIA FOR MINIMUM CAPACITY (OR TORQUE) AND
MINIMUM EMBEDMENT DEPTH HAS BEEN ACHIEVED.
9. HELICAL PILES SHALL BE DESIGNED AND MANUFACTURED IN ACCORDANCE WITH THE 2009
INTERNATIONAL BUILDING CODE (IBC -09).
10. HELICAL PILES do PUSH PILES SHALL BE ICC -ES CERTIFIED IN COMPLIANCE WITH AC358.
TOWN OF YARMOUTH
Scott Orlowski, P.E.
vski, P.E., o=Apex
REVIEWED FOR BUILDING AND ZONING CODE COMPLI-
ANCE. ERRORS OR OMMISSIONS DO NOT RELIEVE THE
APPLICANT FROM THE RESPONSIBILITY OF 'AS BUILT"
COMPLIANCE.
DATE:
BUILDING O L
APPLICANT'S COPY
11. PILES AND COMPONENTS SHALL CONFORM TO THE FOLLOWING CRITERIA:
*PILE SHAFT; ROUND W/ WALL THICKNESS=0.175' - ASTM A500 (Fy=46 KSI)
*HELICAL & OTHER FLAT PLATES: MIN. THICKNESS -3/8' - ASTM A36 (Fy=36 KSI)
*CONNECTING BOLTS - SAE J429 (GRADE 8)
*WELDING - AWS D7.1 (EWXX ELECTRODES)
12. ONLY ROUND SHAFT PILES ARE TO BE USED.
14. HELICAL PLATES ARE TO BE AMINIMUM OF 3/8' THICK
15. PILES ARE TO BE INSTALLED PER MANUFACTURES SPECIFICATION.
16. PILE CONTRACTOR TO CREATEDRIVE LOGS AND DOCUMENT THE FOLLOWING FOR EACH PILE;
*PILE NUMBER,
►INSTALLATION DATE,
*DRIVER USED TO INSTALL PILE,
*PILE DIAMETER,
*HELICAL PLATE CONFIGURATION,
*INSTALLATION DEPTH,
*INSTALLATION TORQUE,
*INSTALLATION PRESSURE,
17. MATERIAL INVOICE, DRIVE LOGSi AND AT LEAST ONE PHOTOGRAPH OF EACH INSTALLED PILE
(W/ PILE NUMBER WRITTEWON THE PILE) ARE TO BE SUBMITTED TO THE ENGINEER W/IN
72 HOURS OF INSTALLATION.
18. ALL VOIDS BETWEEN BRACKET d BOTTOM OF FOUNDATION ARE TO BE FILLED SOLID WITH
QUIKRETE NON -SHRINK GENERAL PURPOSE GROUT AND ALLOWED TO CURE FOR NO LESS
THAN 24 HOURS BEFORE APPLYING ANY LOAD TO THE BRACKET.
19. ENGINEERING STAMP IS FOR DESIGN OF PILES ONLY, WITH CONDITIONS AS SHOWN ON THIS
SHEET.
20. THE ENGINEER DOES NOT CERTIFY PILE INSTALLATION UNTIL ADEQUATE DRIVE LOGS AND
PHOTOS ARE SUBMITTED TD THE ENGINEER, AND A LETTER OF ACCEPTANCE HAS BEEN
ISSUED.
21. CENTERLINE OF PILE IS TO BE NO MORE THAN 3' FROM THE LOCATION SHOWN WITH WRITTEN
APPROVAL FROM THE ENGINEER.
22. ENGINEER IS TO BE NOTIFIED IMMEDIATELY IF ANY UNFORESEEN OBSTRUCTIONS ARE
ENCOUNTERED.
23. ENGINEER IS TO BE NOTIFIED IF MINIMUM CAPACITY, MINIMUM EMBEDMENT DEPTH, OR PLUMB
REQUIREMENT CANNOT BE REACHED.
24. ON SITE SUBSTITUTIONS WILL NOT BE ACCEPTED W/O PRIOR WRITTEN APPROVAL BY THE
ENGINEER.
� U
o, W%N rn
C
g<
N C
rr•• ll0 LU N
LLpU) Q
�_in
aD U ..
Lo
WiamDF:
AMI FDR:
CONSTRUCTION
kmm JULY 13.2017
ME, AS NOTED
DPAV-11 D1: SRO
DOWNED SRO
U)
W
U i-
<
U w
0 z
0 00
W (n
:� Z -0 W M
Z F_
Z W Woo
Q Q ly Z02�
Q
Z m }�2
:) Z O 0aF-
00-1
-
0OJ Qn o
IL v c5 2 °
DFAM"amm:
PLAN & NOTES
DFAWM HU. -NEL"
ST1
WE DUMM:
1 OF 1
j" 19 MDEF.
17-044