Loading...
HomeMy WebLinkAboutEngineered Plan - 2016N LOCUS MAP ACCESS COVERS MUST BE TO FINISH GRADE \FIRST 2' TO BE LEVEL -7 s BAFFLES 92.62 �'X J*0 92.2 2160 G M1N 1080 G M1N 3 OUTLET ftxwx D -BOX 3500 GALLON H-20 2 -EXISTING PITS 2 COMPARTMENT 6" CRUSHED STONE OR SEPTIC TANK COMPACTED BASE H-20 PROF i L E : NOT TO SCALE \,p OFA\G� 96.22 Z� EXIS, i 2000 SEPT 01 SECOND .UMBING 95.6 CO _ NEW _. D -80X i -0 EXISTING LEACH PIT/ 95.47 i �i 96.2/ i ' � C ®CA*H BASIN l RI,M-95.04 / UP 1067/3 BM C8/DH FAV EL -97.35 DESIGN CRITERIA DESIGN FLOW: 2nd FLOOR DAYCARE AND DENTIST 68 PERSON DAYCARE AT /0 GPD PER PERSON EQUALS 680 GPD 2 DENTIST DENTAL OFFICE AT 200 GPD PER DENTIST EQUALS 400 GPD TOTAL FLOW EQUALS 1080 GPD SEPTIC TANK REQUIRED: 2 COMPARTMENT 1080 G.P.D. X 200% - 2160 GAL. Ist COMPARTMENT 1080 G.P.D. X 1009 - 1080 GAL. 2nd COMPARTMENT SEPTIC TANK PROVIDED: 3500 GAL. 2 COMPARTMENT 2 EXISTING 6' DEEP x 6' DIAMETER LEACH PITS WITH 2' STONE AROUND. BY 1978 TITLE 5 S 1 DE - 2 x 3.14 x 5 x 6 - 188 SF x 2.5 - 471 GPD BOTTOM - 3.14 x 5 x 5 - 78 SF x /. 0 - 78 GPD TOTAL - 266 SF 549 GPD 2 PITS - 532 SF 1098 GPD ® C8 CONCRETE BOUND —W WATER L I NE O HYDRANT G GAS LINE OHW— OVER HEAD WIRES -0- LIGHT POST --E— UNDERGROUND ELECTRIC LINE —T— UNDERGROUND TELEPHONE LINE — CTV— UNDERGROUND CABL EV I S I ON LINE -I- 40.4 SPOT ELEVATION _--40 ....... EXI STING CONTOUR 40 'PROPOSED CONTOUR Yarmouth Health Department APPROVED Naame Date GENERA NO TES : I. THIS PLAP 1S FOR THE DESIGN AND CONSTRUCTION OF THE S WAGE D l SPOSAL SYSTEM ONLY. 2. VERTICAL DATUM IS ASSUMED. FOR BENCH MARKS SET. SEE SITE PLAN. J. ALL CONS RUCTION METHODS AND MA TER I AL S AND MA I NTENA CE OF THE SEPTIC SYSTEM SHALL CONFORM 10 MASS. D.E.P. TITLE 5 AND LOCAL BOARD OF HEALTH REGULATIONS. 4. ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER AREAS SU JECT TO VEHICULAR TRAFFIC OR GREATER THAN 3' IN DEPTH SHALL BE CAPABLE OF WITH- STANDING H-20 WHEEL LOADS. 5. ALL SEWS PIPE SHALL BE SCHEDULE 40 PVC OR APPROVED EQUAL. 6. SEPTIC TANK AND D -BOX SHALL BE REINFORCED PRECAST CONCRETE OR APPROVED POLYETHYLENE. BOTH SHALL BE WATERTIGHT. D -BOX SHALL BE WATER TESTED FOR LEVEL WHEN THERE IS MORE THAN ONE OUTLET. 7. BEFORE C NS TRUCT I ON CALL -DIG- SAFE " . 1-888-DlL-SAFE AND THE LOCAL WATER DEPT. FOR L DCA Til ON OF UNDERGROUND UTILITIES. SEPT / C SYS TEM DES/ON 923 ROUTE 54. MAP 143, ARCEL l l l Yom,RMOUTHPOR T MA PREPARED FOR CHARTER TWO L L C SCAL E / 20 MAY 6 20 / 6 STEPHEN A HAAS ENGINEERING, INC P.O. Box 16 Sou t h Den r i s MA 02660 508) 362-8 1 32 JOB NO: 99-/44