Loading...
HomeMy WebLinkAboutEngineered Plans - 2017BED BED RM RM �P BED RM LIV RM AM. Roo FLOOR PIAN 6Gc 'f)y Permit valid for REPAIR O) SEPTIC SYSI-tM ONLY, due to State and Local septic variances. Board,of Ilealth review and approval is required for any future additions/rcu,:. anon,,/atteratioos to sewage facilities and/or strucim esid++cilirig. Yarmouth Health Department APPRQVEll/.,�OF ame , Date Id•2s •c'1 Survey by. Weller & Assoc. SOUTH YARMOUTH LOCUS INFORMATION PLAN REF: BK 172 PG 1 TITLE REF: BK 2890 PG 162 PARCEL ID: MAP 088 PAR. 197 FLOOD ZONE: "X" COMMUNITY PANEL: 25001CO587J DATED:07/16/14 SEPTIC SYSTEM REPAIR PLAN LOCATED AT: 34 BUCKWOOD DR. SOUTH YARMOUTH, MA PREPARED FOR CRAIG R. WHITTEN OCTOBER 16, 2017 1141 'I MEYER & SONS INC. P.O. Box 981 E. SANDWICH, MA 02537 PH. (508)360-3311 fax (774)413-9468 meyerandsonstitle5@gmail.com SHEET 1 OF 2 .1.41 RRn LEGEND ��--�- PROPOSED CONTOUR ® PROPOSED SPOT GRADE — — 98 -- EXISTING CONTOUR + 96.52 EXISTING SPOT GRADE W— APPROX WATER SERVICE TEST PIT SCALE: 1"=20' BED BED RM RM �P BED RM LIV RM AM. Roo FLOOR PIAN 6Gc 'f)y Permit valid for REPAIR O) SEPTIC SYSI-tM ONLY, due to State and Local septic variances. Board,of Ilealth review and approval is required for any future additions/rcu,:. anon,,/atteratioos to sewage facilities and/or strucim esid++cilirig. Yarmouth Health Department APPRQVEll/.,�OF ame , Date Id•2s •c'1 Survey by. Weller & Assoc. SOUTH YARMOUTH LOCUS INFORMATION PLAN REF: BK 172 PG 1 TITLE REF: BK 2890 PG 162 PARCEL ID: MAP 088 PAR. 197 FLOOD ZONE: "X" COMMUNITY PANEL: 25001CO587J DATED:07/16/14 SEPTIC SYSTEM REPAIR PLAN LOCATED AT: 34 BUCKWOOD DR. SOUTH YARMOUTH, MA PREPARED FOR CRAIG R. WHITTEN OCTOBER 16, 2017 1141 'I MEYER & SONS INC. P.O. Box 981 E. SANDWICH, MA 02537 PH. (508)360-3311 fax (774)413-9468 meyerandsonstitle5@gmail.com SHEET 1 OF 2 .1.41 RRn M T.O.F. NOTE: MAGNETIC TAPE TO BE PLACED OVER ALL COVERS EL: 40.0 NOTE: PLACE RISERS OVER ALL COVERS W/IN 6" OF GRADE FINISHED GRADE (36.0) �F.G.EL: 38.0 /- F.G,EL: 37.00 F.G. EL: 36.0 --� MAINTAIN 2% MIN SLOPE OVER LEACHING AREA 2" OF 3/8" DOUBLE WASHED STONE OR FILTER FABRIC 6" 1 U4" SCH 40 PVC 10"I ' A_ TEE'S ARE TO BE 14 6@ S= 17. (MIN.) :4 SCH 4o PVC INV.32.95 4 2' EFF. DEPTH :." INV.33.65 GAS � INV.32.75 4' EXIST. INVERT BAFFLE PROPOSED DB -3 ••} DISTRIBUTION BOX INV. 36.78 INV. 33.90 a (H-20) INV. ELEV.= 32.50 EXIST. 1,000 GALLON SEPTIC TANK GAS BAFFLE TO BE INSTALLED ON ���` OF Mgrs OUTLET TEE AS MANUFACTURED BYo E�9�y� TUF-TITE, ZABEL, OR EQUAL EIN TOP CONC. ELEV.= 33.50 NOTES: 1) CONTRACTOR SHALL VERIFY A►1 EXISTING N ,'140 I� INV. ELEV.= 32.50 PIPE INVERTS PRIOR TO CONSTRUCTION - 2) D -BOX SHALL BE SET LEVEL AND TRUE TO GRADE ON A MECHANICALLY COMPACTED SIX NITAR�P� `� j� BOTTOM EL.= 30.50 INCH CRUSHED STONE BASE, AS SPECIFIED IN 01 p I 310 CMR 15.221(2) 3) REPLACE EXISTING 1,000 GALLON SEPTIC TANK SEPARATION 5.08 FT. WITHED, GALLON SEPTIC TANK IF FAILED, SEPTIC SYSTEM PROFILE DAMAGED, OR UNDERSIZED. 4) INSTALL INLET & OUTLET TEES W/ GAS BAFFLE AS REQUIRED GENERAL NOTES: I. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE LOCAL RULES AND REGULATIONS, EXCEPT AS REQUESTED BELOW: - 310 CMR 15.405 (1) (B): 1) A 1.0 Fr. VARIANCE FROM 310CMR15.211 TO ALLOW LEACHING TO BE 19.0 FT (MAX) FROM DWELLING VS REWD 20 Fr. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY PROVIDED BY MUNICIPAL WATER. 8. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR. 9. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. 10. EXISTING LEACHING TO BE PUMPED, CRUSHED AND REMOVED PER TITLE 5. REPLACE WITH CLEAN MEDIUM SAND PER TITLE 5. 11. 48 HOUR NOTICE FOR ENGINEER CERTIFICATION 12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND IS NOT TO BE CONSIDERED A PROPERTY UNE SURVEY 13. NO PRIVATE WELLS WITHIN 150' OF PROPOSED LEACHING. 14. NO WETLANDS WITHIN 100' OF PROPOSED LEACHING. 15. ALL PIPING TO BE 4" SCH 40 0 1/8" /FT (UNLESS SPECIFIED) SOIL: LOGS 3/4" - 1-1/2" DOUBLE WASHED STONE E30. O 0000 aaaaa00aa 000000000 aaaaaaaaa 2 X 8.5' EFFECTIVE LENGTH = 25' BREAKOUT ELEV. = 33- S ®a as aaa aaaaaaa aaaaaaa 3.75' I 5 FT. 3.75' EFFECTIVE WIDTH = 12.5' BOTTOM OF TESTHOLE EL: 25.42 ---�- SOIL ABSORPTION SYSTEM (SECTION) DATE: OCTOBER 11, 2017 SOIL EVALUATOR: DARREN MEYER, CSE 1614 WITNESS: PHIL RENAUD, YARMOUTH HEALTH Elev. TP -1 Depth 36.0 0" A LOAMY SAND 10YR 4/1 35.33 8- B LOAMY SAND tOYR 5/6 33.18 34" C PERC TEST MEDIUM SAND O EL 31.5 2.5Y 6/4 25.42 I 127" PERC RATE <2 MIN/IN. ('C2" HORIZON) PER SIEVE TEST NO GROUNDWATER OBSERVED I, Darren M. Meyer, R.S., CSE, hereby certify that 1 am currently approved by MADEP pursuant to 310 CMR 15.017 to conduct soil evaluations and that the above analysis has been performed by me consistent with the requirements of 310 CMR 15.017. 1 further certify that I have passed the Soil EvaL Exam in October, 1999. (500 GALLON LEACH CHAMBER) DESIGN CRITERIA **NO PROPOSED INCREASE IN FLOW** NUMBER OF BEDROOMS: 3 BEDROOM DESIGN SOIL TEXTURAL CLASS: CLASS 1 (0.74 GPD/SF) DESIGN PERCOLATION RATE: <2 MIN/IN DAILY FLOW: 110 G.P.D. X 3 BR = DESIGN FLOW: 330 G.P.D. GARBAGE GRINDER: NO (not designed for garbage grinder) SEPTIC TANK: 330 gpd x 200% = 660 gpd, USE EXIST. 1,000 GAL. SEPTIC TANK LEACHING AREA REQUIRED: (330) = 445.94 S.F. .74 USE TWO (2) 500 GALLON PRECAST LEACH CHAMBERS W/ 4' STONE ON ENDS & 3.75' STONE ON SIDES: 25' L x 12.5' W x 2'D BOTTOM AREA: 25' x 12.5'= 312.50 SF SIDE AREA: (25 + 12.5) X 2 X 2 = 150 SF TOTAL SQUARE FEET PROVIDED = 462.50 vs. 445.94 REQ'D DESIGN FLOW PROVIDED: 0.74(462.50 S.F.) = 342.25 G.P.D. vs. 330 G.P.D. req'd PROPOSED SEPTIC SYSTEM UPGRADE PLAN 34 BUCKWOOD DR., SO. YARMOUTH, MA Prepared for: Whitten System Design and Topography Pian by: SCALE DRAWN MEYER & SONS, INC. N.T.S. DMM PO BOX 981 EASTS41VOWiCH, MA 02537 DATE CHECKED SHEET NO. 508362-29,22 10/16/17 DMM 2 of 2