Loading...
HomeMy WebLinkAboutEngineered Plans - 2017EXISTING S.A.S.- TO A.S- TO BE REMOVED (SEE NOTE 11) '6 9:,... 100,07 .� , . sem• EXIS71NG SEPTIC TANK TOP OF TANK=101.19 INV. (DU T)= 99.86± L,q`r'ct' OWNER OF RECORD BENNETT, RICHARD R BENNETT, THEODORA 11 PINE CONE DRIVE WEST YARMOUTH, MA 02673 - --102 - — EXISTING CONTOUR 0 o x 100.98 EXISTING SPOT GRADE Rta 28 o —W EXISTING WATER SERVICEgsilver N --- — EXISTING GAS SERVICE o` OVERHEAD WIRES � s a E� TEST PIT N t v BENCHMARK Cutter nv Brookhill La Pram i d N Cutter L S LEGEND 2O )0Yacht Avevaf LnSilver Leaf Ln Pine St Rainbow Rd_To LEWIS BAY - LOCUS MAP NOT TO SCALE GENERAL NOTES: 1 BDFETHDSSBEAPPROVED NEOR ED BY THE LOCAL OAROHALTTHAND THE DESIGN 2 OF WK HOERSTATED ENV RONMENTTERIALS AL CODON TORE V, AND ANTO THE Y AIPPLICABLE LOCAL RULES AND REGULATIONS. 3 THE SEWAGE INSPECTIONI AND APPROVASPOSAL L BY SHALL N BY THEBOARD OFOT BE C KFILLED PRIOR TOHEALTH AND THE DESIGN ENGINEER. 4 ANY FROMCTTHOSEONS SHOWN ENCOUNTERED SHALLN E CONSTRUCTION TIREPOR REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON AN ASSUMED DATUM. 6 THE CONTRACTOR NORRIS T THE DESIGN OWNERTOENOTTIFYIBLE FOR THE FAILURE OF THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. 8. THERE ARE NO WELLS WITHIN 100' OF THE PROPOSED S.A.S. 9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE DIRECTED BY THE APPROVING AUTHORITIES. 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION, 11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3), 12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE INSPECTED BY DESIGN ENGINEER PRIOR TO BACKFILL. 13. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND NOT CONSIDERED TO BE A PROPERTY LINE SURVEY, MAP ID: 22-104 PROPOSED SEPTIC SYSTEM UPGRADE PLAN 21 SILVER LEAF LANE, WEST YARMOUTH MA Prepared for: D.A. Brown, Inc., P.O. Box 145, Centerville, MA 02632 Engineering by: Survey Review by: SCALE DRAWN JOB. NO. Engineering Works, Inc. JC Engineering, Inc. 1$'=20' P.T.M.---- 254-17 12 West Crossfield Road 2854 Cranberry Hwy. PATE CHECKED SHl„ET NO. Forestdale, MA 02644 E.Warehom, MA 02538 11/8/17 P.T.M. 1 Of 2 (508) 477-5313 (508) 273-0377- NOTE: TO PREVENT BREAKOUT, THE PROPOSED FINISH GRADE SHALL NOT BE < EL: 99.5 FOR A DISTANCE OF 15' AROUND THE PERIMETER' OF THE S.A.S. / j SEPTIC TANK PROPOSED D -BOX PROPOSED S.A.S. INSTALL RISERS & COVERS OVER INLET & INSTALL RISER AND COVER INSTALL RISER & COVER OVER ONE CHAMBER(MIN.)`,. EXISTING OUTLET AND SET TO 6" OF FINISH GRADE SET TO WITHIN 6" OF FINISH AND SET TO WITHIN 3" OF FINISH GRADE TO SERVE HOUSE(#29) T.O.F.=102.9± GRADE AS AN INSPECTION MANHOLE. T.O.F.=� EXISTING F.G. EL.=102.8± F.G. EL.=102.5± F.G. EL.=102.3± 2 L = 24' L = 28'(MAX) DECK ®"S=1% (MIN.) (MIN. ) " "S=1% 4SCH40 PVC 4SCH40 PVC 2" LAYER OF 1 /8„- io"I •ia" INV.=96.85 48" LIQUID s" 12" INV.=99.86± TO 1 /2 DOUBLE WASHED STONE ®O ®A14�' (OR APPROVED FILTER FABRIC) co o CV N LEVEL • GAS BAFFLE INV.=99.28 (FIELD VERIFY) PROPOSED 4' 3' 3/4"-1 1/2 K� aj'`� p, D -BO EFFECTIVE WIDTH = 11 DOUBLE WASHED ___ __ INV.=99.45 W/INLET TEE INV.=99.00 STONE -__ TT I EXISTING TI NK H-20 RATED USE 5 LC -6 LEACHING CHAMBERS IN SERIES WITH ROP. S.A.S. 4' OF STONE ON SIDES & 1.5' OF STONE ON ENDS �� H-20 RATED ----33'_I NOTES: TOP CONC. ELEV.=99.83 - BREAKOUT S.A.S. LAYOUT 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INV. ELEV.=99.00E3 E3 E3 O E3 EM E3 ELEV.=99.5 mi INVERTS, PRIOR TO INSTALLATION. E3 E3 E3 E3 E3 E3 E3 2) D -BOX SHALL BE SET LEVEL AND TRUE TO BOTTOM ELEV.=98.00 GRADE ON A MECHANICALLY COMPACTED SIX 1 1.5' 5 x 6' = 30' 1.5' INCH CRUSHED STONE BASE, AS SPECIFIED IN 4' OF NATURALLY OCCURRING EFFECTIVE LENGTH = 33' r 4' KNocKouT 310 CMR 15.221(2). PERVIOUS MATERIAL 20" 0u. COVER 3) INSTALL INLET & OUTLET TEES AS REQUIRED. 5' (MIN.) ABOVE G.W. I 4) GAS BAFFLE TO BE INSTALLED ON OUTLET TEE BOTTOM OF TP„ EL=90.3 = LEACHING SYSTEM SECTION - M AS MANUFACTURED BY TUF-TITE, ZABEL OR EQUAL. EST. HIGH G.W., EL.=93.0 a" KNOCKOUT a" KNOCKOUT SEPTIC SYSTEM PROFILE L - _ - - - _ a" KNOCKOUT - - J N.T.S. I - I 2 PLAN VI SOIL LOG DESIGN CRITERIA DATE: SEPTEMBER 21, 2017 SOIL EVALUATOR: PETER McENTEE (SE#1542) - - - - - - - - NUMBER OF BEDROOMS: 2 BEDROOMS WITNESS: PHILIP RENAUD - HEALTH AGENT ® 0 ® ® ® z2" ® 0 SOIL TEXTURAL CLASS: CLASS I DESIGN PERCOLATION RATE: <2 MIN/IN Elev. TP Depth INV2RT ®®®®®®® I I 102.3 0" DAILY FLOW: 220 GPD (DESIGN FOR 3) LOAMY SANDr- 7z" r - DESIGN FLOW: 330 GPD 101.8 10YR 4/2 6„ SIDE VIEW ENDD VIEW GARBAGE GRINDER: NO -AND NOT PERMITTED WITH THIS DESIGN B LOAMY 0YR 5/8D PERC WIGGIN LC -6, H-20 LOADING EXISTING SEPTIC TANK: 1000 GALLON CAPACITY 99.3 136/36 LEACHING CHAMBER LEACHING AREA REQUIRED: (330 GPD) = 445.9 SF .74 GPD/SF MED. SAND N.T.S. 2.5Y 6/4 PROPOSED SEPTIC SYSTEM UPGRADE PLAN USE 5 LC -6 LEACHING CHAMBERS IN SERIES WITH ADJ. G.W. /� 2 1 1 SILVER LEAF LANE, WEST YARMOUTH, MA 4 FT. OF STONE (SIDES) & 1.5 FT. STONE (ENDS) 93.0 REDOX _ 112" 7.5YR 5/8 Prepared for: D.A. Brown, Inc., P.O. Box 145, Centerville, MA 02632 SIDEWALL AREA: (11.0' + 33.0') x 2 x 1' = 88.0 SF 90.4 STG. G.W. _ 143" Engineering by: Survey Review by: SCALE DRAWN JOB. NO. BOTTOM AREA: 11.0' x 33.0' = 363.0 SF 90.3 144" STANDING G.W. ® 143"" (EL.=90.4) Engineering Works, Inc. JC Engineering, Inc. N.T.S. P.T.M. 254-17 TOTAL AREA: ........................................................... 451.0 SF ADJ. HIGH G.W., EL.93.0 (REDOX/MOTTLING) 12 West Crossfield Road 2854 Cranberry Hwy. PERC RATE 5 MIN/IN. ("B" HORIZON) Forestdale, MA 02644 E.Wareham, MA 02538 DATE CHECKED SHEET NO. DESIGN FLOW PROVIDED: 0.74 GPD/SF(451.0 SF) = 333.7 GPD PERC RATE 2 MIN/IN. ("C" HORIZON) (508) 477-5313 (508) 273-0377 11/8/17 P.T.M. 2 of 2