Loading...
HomeMy WebLinkAboutEngineered Plans - 2017— —102— — EXISTING CONTOUR x 100.98 EXISTING SPOT GRADE UGW UNDERGROUND WIRES —W—EXISTING WATER SERVICE EXISTING GAS SERVICE TEST PIT BENCHMARK LEGEND 104.67 S 43'52'10" E 54.98. SHED f` i I x 105.19 x 10 6.7 6 107.28 107.37 x LOT 3 19,081 ±SF x 107.21 x 107,25 v; 6� (s. BENCHMARK OUTSIDE CORNER OF BOTTOM STEP EL. = 98.08 EXISTING SEPTIC TANK - TOP OF TANK, EL. =105.60 1N V. (OUT)=104.27f-(VERIFY) I x 108.94 " x 108.50 7x10 R=840.00' L=121.23' x 108,2 -,10736 DECK \ DECK x ` PEN HOUSE(# 12 1) T.O.F.=108.4f I BM I 108,0 �0 85 107.46 x a �Q N O Cr o m O Z P s sE7zj 7' o LOCUS LOCUS MAP NOT TO SCALE x 108.22 SHE i i x 08.19 I ti 10 ' f --12. to 8' 78 6,46 • - ..PAVEMENT'..- 107.95 �' .0 8S:.... . rn.C4 0 jL, x1 p- LAMP PROPOSED SEWER CONNECTION TP:�; 104.49 105.25 EXISTING S.A.S. TO BE PUMPED, FILLED WITH X04.. 103,99 SAND AND ABANDONED 0 105.31 104.70 �D 'J x 103,74 GS Yarmouth Health rtment PP 1 ED L. me Date ��P��� OF Mgss9�yG o PETER T. McENTEE S CIVIL No. 35109 -- Bent/berm — 100.28 SETUCKET ROAD 'V"" `" OWNER OF RECORD l .L'0 LUDWIG, JASON A McCORMICK, CHRISTINE 121 SETUCKET ROAD YARMOUTH PORT, MA 02675 MAP ID: 144-2 -11 I\ - V- 0 .67 i CATCH BASIN 99.56 99.72 PROPOSED SEPTIC SYSTEM UPGRADE PLAN 121 SETUCKET ROAD, YARMOUTH PORT, MA Prepared for: Jason Ludwig, 121 Setucket Rd, Yarmouth Port, MA 02675 Engineering by: SCALE DRAWN JOB. NO. Engineering Works, Inc. 1 "=20' P.T.M. 270-17 12 West Crossfield Road, Forestdole, MA 02644 DATE CHECKED SHEET NO. (508) 477-5313 116/17 P.T.M. 1 Of 2 NOTE: TO PREVENT BREAKOUT, FINAL GRADE SEPTIC TANK SHALL NOT BE AT, OR BELOW, EL.=103.5 INSTALL RISERS & COVERS OVER INLET & FOR A DISTANCE OF 15' FROM THE EDGE OUTLET AND SET TO 6" OF FINISH GRADE PROPOSED D -BOX OF THE PROPOSED S.A.S. PROP. SEWER CONNECTION INSTALL RISER & COVER PROPOSED S.A.S. IF INVERT BELOW EL.=103.80 SET TO 6" OF GRADE INSTALL RISER & COVER OVER ONE CHAMBER AND 8.4± USE H-20 CHAMBERS & VENT SET TO 3" OF F.G. TO SERVE AS INSPECTION PORT TLF.G.EL.=107.8± F.G. EL=107.7± F.G. EL=106.5± F.G. EL.=105.8 to 106.8± CHARCOAL VENT (IF BELOW 3 FT.) MANTAIN 2% SLOPE OVER S.A.S. r EX. D -BOX L = 40' L = 23' F 1 @ S=1% (MIN.) ® S=1% (MIN.) • I I 4"SCH40 PVC 4"SCH40 PVC 2" LAYER OF 1/8" TO 1/2" DOUBLE WASHED STONE 11 io"I. L 6 aaaSBaa (OR APPROVED FILTER FABRIC) t4" a6aa9aa EXISTING 48' LIQUID aaaaaaB --3/4" TO 1-1/2" DOUBLE LEVEL ADD 1 PROPOSED 4' 4.8' 4' WASHED STONE INV.=103.40 INV.=103.23 GAS BAFFLE D -BO EFFECTIVE WIDTH = 12.8' INV.=104.27± (VERIFY) 3 OUTLETS INV.=103.00 EXISITNG SEPTIC TANK H-20 LOADING IF DEEPER THAN 3 FT. 3-500 GALLON LEACHING CHAMBERS SURROUNDED WITH STONE AS SHOWN NOTES: TOP CONC. ELEV.=103.80 1 CONTRACTOR SHALL VERIFY ALL EXISTING PIPES & BREAKOUT ELEV.=103.50 INVERTS EXITING HOUSE, PRIOR TO INSTALLATION. aaaB INV. ELEV.=103.00 eases 2) D -BOX SHALL BE SET LEVEL AND TRUE TO aaaeaaaaaaa GRADE ON A MECHANICALLY COMPACTED SIX BOTTOM ELEV.=101.00 INCH CRUSHED STONE BASE, AS SPECIFIED 4' 3 x 8.5' = 25.5' 4' IN 310 CMR 15.221(2). 4' OF NATURALLY OCCURRING EFFECTIVE LENGTH = 33.5' 3) INSTALL INLET & OUTLET TEES AS REQUIRED. PERVIOUS MATERIAL - 4) GAS BAFFLE TO BE INSTALLED ON OUTLET TEE 5' (MIN.) ABOVE G.W. LEACHING SYSTEM SECTION AS MANUFACTURED BY TUF-TITE, ZABEL OR EQUAL. BOTTOM OF TEST PIT, EL.=94.8 SEPTIC SYSTEM PROFILE EXISTING I ! I r J HOUSE 121 j ?I 1 GENERAL NOTES: T.O.F.=108.41 I i GARAGE I 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL ( i BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS n0 N OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE p LOCAL RULES AND REGULATIONS. C. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 13.- ' 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING 26.2' FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON AN ASSUMED DATUM. ' cV ' 8� ' ' 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF (A ' THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF (P HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. O- raj 8. THERE ARE NO WELLS WITHIN 100' OF THE PROPOSED S.A.S. 9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE DIRECTED BY THE APPROVING AUTHORITIES. 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY SEPTIC LAYOUT THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. SOIL LOG 11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3). 12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE DATE: SEPTEMBER 19, 2017 INSPECTED BY HEALTH DEPARTMENT PRIOR TO BACKFILL. SOIL EVALUATOR: PETER MCENTEE PE(SE#1542) 13. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND WITNESS: PHILLIP RENAUD R.S. HEALTH AGENT IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY. ELEV. TP DEPTH 105.3 A 0" LOAMY SAND 10YR 4/1 104.8 g" B LOAMY SAND 10YR 5/8 102.3 36" C PERC DESIGN CRITERIA 26"/44" NUMBER OF BEDROOMS: 4 SOIL TEXTURAL CLASS: CLASS I MED. SAND DESIGN PERCOLATION RATE: <2 MIN/IN 2.5Y 6/4 (0.74 GPD/SF LOADING RATE) DAILY FLOW: 440 GPD DESIGN FLOW: 440 GPO GARBAGE GRINDER: NO s4.s 12s" LEACHING AREA REQUIRED: (440 GPD) = 594.6 SF PERC RATE <2 MIN/IN. "C" HORIZON .74 GPD/SF NO GROUNDWATER ENCOUNTERED EXISTING SEPTIC TANK: 1000 GALLON CAPACITY PROPOSED SEPTIC SYSTEM UPGRADE PLAN PROPOSED DISTRIBUTION BOX: 1 INLET, 3 OUTLETS USE 3-500 GALLON LEACHING CHAMBERS IN SERIES 121 SETUCKET ROAD, YARMOUTH PORT, MA SURROUNDED BY DOUBLE WASHED STONE ON ALL SIDES SIDEWALL AREA: 2(12.8' + 33.5') X 2 = 185.2 S.F. Prepared for: Jason Ludwig, 121 Setucket Rd, Yarmouth Port, MA 02675 BOTTOM AREA: 12.8' x 33.5' = 428.8 S.F. Engineering by: SCALE DRAWN JOB. NO. TOTAL AREA: .............................................................. 614.0 S.F. Engineering Works, Inc. N.T.S. P.T.M. 270-17 DATE 11/6/17 CHECKED P.T.M. SHEET NO. 2 Of 2 DESIGN FLOW PROVIDED: 0.74 GPD/SF(614.0 SF) = 454.4 GPD 12 West Crossfield Road, Forestdale, MA 02644 (508) 477-5313