HomeMy WebLinkAboutEngineered Plan - 2017TOP FOUND. EL 24.7' PRECAS RISERS (TYP.)T H-10 = 2'0 21.46'/ SYSTEM PRO I L E BE A" SYEMMRK EXIST. SPOT ELEV. -[99]--- F D�WITHCMAGNETICTTAPEALL OR TH1 2. MUNICIPAL WATER IS EXISTING -0- TEST HOLE COMPARABLE MEANS FOR FUTURE LOCATION. SLOPE OF GROUND (NOT TO SCALE) moo o� FIRE HYDRANT..... .._. NONE NOT ALL SYMBOLS 6/AY APPEAR IN ORAIMNG PROVIDE MIN. 20" DIAM: WATERTIGHT 4. DESIGN LOADING FOR ALL PROPOSED PRECAST nd' rnrn r UNITS TO BE AASHO H-10 ACCESS COVERS TO WITHIN 6" OF FIN. GRADE. 2" PEASTONE OR GEOTEXTILE S. PIPE JOINTS TO BE MADE. WATERTIGHT. CONCRETE COVERS TO WITHIN 3" GRADE o I n X600 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE FILTER FABRIC OVER STONE WITH 310 CMR 15.000 (TITLE 5.) 9 23.5' MINIMUM .75' OF COVER OVER PRECAST ?, Noyes NOT TO BE USED FOR LOT UNE STAKING OR ANY 2% SLOPE REQUIRED OVER SYSTEM 23.2' pt OTHER PURPOSE. Q . t k • 8. PIPE FOR SEPTIC SYSTEM TO. SCH. 40-4" PVC. NOTE: 2" MIN. WALL rp0 d VVI BLOCKS OR 9, COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD, OF THICKNESS REQUIRED HEALTH AND PERMISSION OBTAINED FROM BOARD PRECAST RISERS 22.66JTE 4"ISSCH40 PVC 10. CONTRACTOR SHALL BE RESPONSIBLE FOR p /� p LOCUS CALLING DIGSAFE (1-888-344-7233) AND IVI/"lI- MORTAR ALL SCALE 1"=2000,'± OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 6" MIN. SUMP T: PIPES LEVEL 13T 2' MAP 78 PARCEL 270 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL COMPONENTS INV'S F1 20.8 (TMP') 4'- PROPOSED LEACHING FACILITY. 12" MIN. INT. DIM. AND REMOVED OR PUMPED AND FILLED WITH CLEAN ENDS/T7 SAND. SIDES 21.6. 10" 1500 GAL H p°GO°e ➢0°' .. ... ' .. ° '. ° ° ° ° ....:.®®�L� 4 TEE SEPTIC TA 21.2L21 ®®®® f ®®® -�®®® >000000go >o���� 0 0 0 0 0 0 WATERTEST D'BOX '°O°°°°°°®®��®®0®�� 0 0 0 0 L9®®����®�®� > 0000000 GAS BAFFLE '' o 0 0 0 0 0 °O�0o0�°�°�° FOR LEVELNESS w. ,,,f,.'• > ° ° o ° ®®®®® ®®®®� �0°0°0°0° ®®�®®�®®�®� ® ®® ®®� ®����®®�®®®°O°O°°°O >°°°O°O°° ° ° ° ° 0000°O°O 'O° -°o°°° g°o°o�o° 1 18.8 4' UQ. LEVEL (ACME OR EQUAL) .06' . 20.9' 000a0o00o00000o0o0op0000o00000000000000� 000,0,0,0,0,°,00,o,oQooOoo000,0,,,0,Qo�o,°,0,0,0,0,0o0a0° 3/4"-1-1/2" H-10 DOUBLE WASHED STONE 4. MIN. 500 GAL. LEACHING CHAMBER BY ACME PRECAST (2) UNITS REQUIRED OR EQUAL: ALL AROUND PRECAST STRUCTURES } 6" CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 25.00' X 12.83' L� COMPACTION. (15.221 [2]) 0 ,n (_2.5% SLOPE) FOUNDATION 13' LEGEND as ' EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. -[99]--- PROPOSED CONTOUR 198.41 PROPOSED SPOT EL. TH1 2. MUNICIPAL WATER IS EXISTING -0- TEST HOLE 2 SLOPE OF GROUND Q� UTILITY POLE moo o� FIRE HYDRANT..... .._. NONE NOT ALL SYMBOLS 6/AY APPEAR IN ORAIMNG ( 1 % SLOPE) (1 % SLOPE) 13.8 ADJUSTED GROUNDWATER LEACHING SEPTIC TANK 1.59 D' BOX 12' FACILITY *THE INSTALLER SHALL VERIFY. THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM TEST HOLE LOGS- ENGINEER: OGS ENGINEER. . DANIEL E. GONSALVES, SE #13587 WITNESS: AMY VON HONE,. RS DATE: 9/14/17 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS ELEV. o„ 21.7' 8p FILL A LS 1OYR 4/2 B LS 1OYR 5/6 C MS 1OYR 7/4 15" 30" PERC 120" GROUNDWATER ADJ. DATA: WELL: A7 W-230 ZONE: B ADJUSTMENT: 0.6' (OCTOBER) 19.2' 11.7' GROUNDWATER AT 102" EL. 13.2 DCE # 17-315 1 120•�O _ 23 BENCH MARK - CORNER CONCRETE BULKHEAD G PPLO rON, ELEV. = 24.0 5' REM RVAL ONLY n S�w E(IST. HOUSE I TOF=24.7 900 MAP 78 LOT 270 12,960± S.F. 0.29± ACRES 12Op0, r 3 24r`� I, V `� Scale: I"= 20' 0 10 20 30 40 50 FEET 26.5' NOTES I 1. DATUM IS NAVD 88 0/d Townhouse Rd o ninq 2. MUNICIPAL WATER IS EXISTING moo o� 3. MINIMUM PIPE PITCH TO BE 1/8". PER FOOT. Locus 4. DESIGN LOADING FOR ALL PROPOSED PRECAST nd' rnrn r UNITS TO BE AASHO H-10 t ooms S. PIPE JOINTS TO BE MADE. WATERTIGHT. o I n X600 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE �� HazeUmoor WITH 310 CMR 15.000 (TITLE 5.) 9 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND ?, Noyes NOT TO BE USED FOR LOT UNE STAKING OR ANY pt OTHER PURPOSE. Q . t k • 8. PIPE FOR SEPTIC SYSTEM TO. SCH. 40-4" PVC. rp0 d VVI 9, COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD, OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR p /� p LOCUS CALLING DIGSAFE (1-888-344-7233) AND IVI/"lI- VERIFYING THE LOCATION OF ALL UNDERGROUND & SCALE 1"=2000,'± OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. ASSESSORS MAP 78 PARCEL 270 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED BENEATH AND 5' AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. SYSTEM DESIGN: GARBAGE DISPOSER 1S NOT ALLOWED DESIGN FLOW: 3 BEDROOMS ® 110 GPD' 330 GPD USE A 330 GPD DESIGN FLOW SEPTIC TANK: 330 GPD 2) = 660 USE A 1500 GAL. SEPTIC TANK LEACHING: SIDES: 2 (25 +1_2.83) (.74) = 112 GPD BOTTOM 25 x 12.83 (.74) = 237 GPD TOTAL: 47� S.F. 349 GPD USE (2) 500 GAL. LEAC ING CHAMBERS (ACME OR EQUAL) WITH 4' STONE ALL AROUND APPROVED DATE BOARD OF HEALTH TITLE 6 -SITE, PLAN OF 87 CAPTAIN BACON ROAD ValrmOutl Ifenith 1Department SOUTH YARMOUTH, MA I APS VED _ PREPARED FOR e Date BUDDY WILLIAMS DATE: OCTOBER 16, 2017 -• t ;L� A OF s� p ���r, OF �s : off 508-362-4541 fox 508-362-9880 *���' DAd.J.IELA tiG i/ DAN! downcope.com OJA 4 I �. O 1 I r1 cin 1i3 • • • CIVILboa cafe ealaeeriaf, lac. ��o���\ civil engineers C4 C) r* J loud surveyors 939 Main 'Street ( Rte 6A) DATE DANIEL A. OJALA, P.E., P.L.S. YARMO THPORT MA 02675 17-315 WILLIAMS.DW(