HomeMy WebLinkAboutEngineered Plan - 2017LEGEND X 991 EXIST. SPOT ELEV. -[991-- PROPOSED CONTOUR 198.41 PROPOSED SPOT EL. TH 1 �e ° e °'yes. rh TEST HOLE 2YYY%,� SLOPE OF GROUND PERC. RATE = __ < UTILITY POLE RE-HXDRAN Pond Bay NOTE. NOT All SYMBOLS MAY APPEAR IN DRAWING ALARM AND CONTROL PANEL TO BE INSTALLED INSIDE BUILDING. ALARM TO BE ON SEPARATE CIRCUIT FROM PUMP i TOP FOUND. EL. 10.6' EXISTING 1500 GAL SEPTIC TANK EXISTING SYSTEM PROFILE NOTES PROVIDE MIN. 20" DIAM. WATERTIGHT (NOT TO SCALE) MARK CORNERS OF 1. DATUM IS NAVD 88 ACCESS COVERS. TO WITHIN 6" OF FIN. GRADE LEACHING FIELD W/ PROVIDE INSPECTION PORTS TO VENT W/ CHARCOAL FILTER 2, MUNICIPAL WATER IS EXISTING REBAR SET 4" BELOW WITHIN 3" OF FINISH GRADE GRADE 27* SLOPE 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. FILTER FABRIC -�- MINIMUM .75' OF COVER OVER PRECAST 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS 10.1' TOP = 9.1' FINISHED GRADE- 4" LOAM & SEED OR PAVE AS REQ. TO BE AASHO H-10 4"0SCH40 PVC CLEAN FILL 5. PIPE JOINTS TO BE MADE WATERTIGHT. s" MIN. SUMP � PIPES LEVEL 1ST 2' CONNECT AND VENT � 6. CONSTRUCTION DETAILS TO BE 0 12" MIN. INT. DIM. IN ACCORDANCE WITH 2" SCH 40 PVC +" PERFORATEo PVC s' o.c. S=0.005 0 310 CMR 15.000 (TITLE 5.) PROPOSED o 7 0'* P1000 GAL. H-10 S = 0.005 SLOPE BACK 9" STONEILEACHINGGOFELD LE WASHED o 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO 6.96UMP CHAMBER TO PUMP CHAMBER 000g000gogoo WATERTEST D'80X 0 6"DEPTH MIN BELOW INV. BE USED FOR LOT LINE STAKING OR ANY OTHER '_00000„0„0_ FOR LEVELNESS 8.75 LEVEL BOTTOM o 8.5 -� �- �� WQz'_ kh 8.94' 8.78' _ �.` /' C-19 A/PURROSF 40.0' 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. s'� ,�ZL��7 /%L�%0000000 00�0�0 0 00000 8.0' 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND 6" CRUSHED STONE OR MECHANICAL PERMISSION OBTAINED FROM BOARD OF HEALTH. SLOPE) FOUNDATION EXISTING SEPTIC TANK 2' - *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS -PRIOR TO- INSTALLING -ANY P-ORTION -- OF SEPTIC SYSTEM -- - PROP. WATERTIGHT COVER TO GRADE PROVIDE QUICK DISCONNECT FOR PUMP INV. IN 6.96' 1 11 L rl"W NO LOW POINTS 1000 GAL. H-10 S/T 2" PRESSURE LINE --- ALARM -- ALARM ON 220 GAL.+ SLOPE TO DRAIN BACK TO PC FLOAT SWITCH RESERVE SETTINGS: PUMP ON 0.25" WEEP HOLES CHECK VALVE 4" WORKING RANGE 8' MYERS SRM 4 4" SUBMERSIBLE 4/10 HP PUMP PUMP OFF 8" SYSTEM (OR EQUAL) 000 c�0000 0 000000 0000 0 0 0000 PUMP CLAMBER (NOT TO SCALE) WATERPROOF/WATERTIGHT SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED EXISTING 4 BEDROOM DWELLING PROPOSED 4 BEDROOM DWELLING DESIGN FLOW: 4 BEDROOMS @ 110 GPD = 440 GPD USE A 440 GPD DESIGN FLOW SEPTIC TANK: 440 GPD (2) = 880 USE EXISTING 1500 GAL. SEPTIC TANK LEACHING: 440 GPD / (.74) = 595 SF REQUIRED 15' X 40' = 600 SF OK 600 SF X .74 = 444 GPD OK USE A 15' X 40' PIPE AND STONE LEACHING FIELD , MA APPROVED DATE BOARD OF HEALTH DCE #17-411 PUMP CHAMBER COMPACTION. (15.221 [2]) 5.0 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING LOCUS MAP ADJUSTED GROUNDWATER 3.0' DIGSAFE (1-888-344-7233) AND VERIFYING THE (1 SLOPE) LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES SCALE 1"=2000'± LOW PROFILE., PRIOR TO COMMENCEMENT OF WORK. 31' D' BOX 5' LEACHING 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE ASSESSORS MAP 17 PARCEL 10 FACILITY REMOVED BENEATH AND 5' AROUND THE PROPOSED LEACHING FACILITY. LOCUS IS WITHIN FEMA FLOOD ZONE AE, _ AE -1-00 --YEAR FLOOD ZONE. (E . 11) -AS- -_-- -- - - EXISTING LEACHING FACILITY SH L P - - - 1A L BE LIMPED AND COMMUNITY PANEL #25001C0588J SHOWN ON CO BUOYANCY CALCS: REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. DATED ON CO 014 H-10 1000 GAL. PC WEIGHS 8,380 LBS 0.8' x 9.0 x 5.25 X 62.4 = 2,380 LBS UP (OK) v 5' REMOVAL OF UNSUITABLE SOIL REQUIRED AROUND PERIMETER OF LEACHING FACILITY, DOWN TO SUITABLE SOIL LAYER. REPLACE WITH CLEAN MED. SAND, TO MEET SPECIFICATIONS OF 310 CMR 15.255(3) -15' X 40' LEACHING .FIELD PROPOSED VENT WITH CHARCOAL FILTER AND BUGSCREEN (FINAL PLACEMENT BY CONTRACTOR WITH OWNER CONSULTATION) FOYER DEN GARAGE LIVING ROOM DINING KITCHEN ROOM BATH FLOOR PLAN -1ST FLOOR NOT TO SCALE ENGINEER: DANIEL E. ° 3 �.F 5 f, . c°t. co c e ° ° •c�'/ �e ° e °'yes. ROOM � m 0 PERC. RATE = __ < h Lewis Lewis Pond Bay Locus Rodeo BED ROOM YARMOU THPOR T MA 02675 Powe d Nantucket G(e ` Sound iOYR 3/2 COMPACTION. (15.221 [2]) 5.0 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING LOCUS MAP ADJUSTED GROUNDWATER 3.0' DIGSAFE (1-888-344-7233) AND VERIFYING THE (1 SLOPE) LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES SCALE 1"=2000'± LOW PROFILE., PRIOR TO COMMENCEMENT OF WORK. 31' D' BOX 5' LEACHING 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE ASSESSORS MAP 17 PARCEL 10 FACILITY REMOVED BENEATH AND 5' AROUND THE PROPOSED LEACHING FACILITY. LOCUS IS WITHIN FEMA FLOOD ZONE AE, _ AE -1-00 --YEAR FLOOD ZONE. (E . 11) -AS- -_-- -- - - EXISTING LEACHING FACILITY SH L P - - - 1A L BE LIMPED AND COMMUNITY PANEL #25001C0588J SHOWN ON CO BUOYANCY CALCS: REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. DATED ON CO 014 H-10 1000 GAL. PC WEIGHS 8,380 LBS 0.8' x 9.0 x 5.25 X 62.4 = 2,380 LBS UP (OK) v 5' REMOVAL OF UNSUITABLE SOIL REQUIRED AROUND PERIMETER OF LEACHING FACILITY, DOWN TO SUITABLE SOIL LAYER. REPLACE WITH CLEAN MED. SAND, TO MEET SPECIFICATIONS OF 310 CMR 15.255(3) -15' X 40' LEACHING .FIELD PROPOSED VENT WITH CHARCOAL FILTER AND BUGSCREEN (FINAL PLACEMENT BY CONTRACTOR WITH OWNER CONSULTATION) FOYER DEN GARAGE LIVING ROOM DINING KITCHEN ROOM BATH FLOOR PLAN -1ST FLOOR NOT TO SCALE FLOOR PLAN -2ND FLOOR NOT TO SCALE TEST HOLE LOGS ENGINEER: DANIEL E. GONSALVES, SE #13587 BED 2 � I BED ROOM � m ROOM PERC. RATE = __ < 2 MIN/INCH civil engineers BED 1 = BED ROOM YARMOU THPOR T MA 02675 m ROOM LS FLOOR PLAN -2ND FLOOR NOT TO SCALE TEST HOLE LOGS GROUNDWATER ADJUSTMENT DATA: WELL: MIW-29 ZONE: A PERC C ADJUSTMENT: 1.9' MS 3.0' ADJ. GROUNDWATER 2.5Y 7/4 77 1.1' Yarmouth Health Department app . FNam c Date H OF Mgss9c r�ZH OF NlASS9C DANIEL*r DANIELA. y�J9 a A. T; 0iAI .A OJALA �' ` Ci':%IL ,O No, 40980 „ , U No. 46502 0A695\0/STGFz -: ;. � DATE DANIEL A. OJALA, P.E., P.L.S. 1 108" I 10.6' GROUNDWATER @102" OR 1.1' TITLE 0 ).nIS ,T 74 BALDWIN LANE WEST, YARMOUTH, MA PREPARED FOR DEBRA SALVUCCI DATE: NOVEMBER 27, 2017 ENGINEER: DANIEL E. GONSALVES, SE #13587 y off 508-362-4541 WITNESS: AMY VON HONE, RS DATE: 11/21/2017 PERC. RATE = __ < 2 MIN/INCH civil engineers CLASS I SOILS 1 ELEV. 0" 9.6' YARMOU THPOR T MA 02675 A LS iOYR 3/2 7" B LS 26" 1OYR 4/3 7.4' GROUNDWATER ADJUSTMENT DATA: WELL: MIW-29 ZONE: A PERC C ADJUSTMENT: 1.9' MS 3.0' ADJ. GROUNDWATER 2.5Y 7/4 77 1.1' Yarmouth Health Department app . FNam c Date H OF Mgss9c r�ZH OF NlASS9C DANIEL*r DANIELA. y�J9 a A. T; 0iAI .A OJALA �' ` Ci':%IL ,O No, 40980 „ , U No. 46502 0A695\0/STGFz -: ;. � DATE DANIEL A. OJALA, P.E., P.L.S. 1 108" I 10.6' GROUNDWATER @102" OR 1.1' TITLE 0 ).nIS ,T 74 BALDWIN LANE WEST, YARMOUTH, MA PREPARED FOR DEBRA SALVUCCI DATE: NOVEMBER 27, 2017 Scale: 1 "= 20' 0 10 20 30 40 50 FEET off 508-362-4541 I fax 508-362-9880 downcope.com 00wn cafe engineering, enc. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOU THPOR T MA 02675 17-411 SALVUCCI.DWG i I