Loading...
HomeMy WebLinkAboutEngineered Plan - Rev. 2018LEGEND 99- EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. -[99]- PROPOSED CONTOUR 198.41 PROPOSED SPOT EL. TH1 •c/Qt\��Gtote s TEST HOLE 2%, SLOPE OF GROUND 71) UTILITY POLE FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING TOP FOUND. EL. 8.6' U "EXISTING 1000 GAL 4.9'* SEPTIC TANK EXISTING ADD ABEL' FILTER PROVIDE MIN. 20" DIAM. WATERTIGHT ACCESS COVERS TO WITHIN 6" OF FIN. GRADE i 6.93' MINIMUM .75' OF COVER OVER PRECAST 0 6.18' 2" SCH 40 PVC PROPOSED 4 88J,F1000 MPLc AMBER S TO PUMP � CHOPE AMBER CK (-L% % SLOPE) FOUNDATION EXISTING - SEPTIC TANK 2' PUMP CHAMBER *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL "INSTALLER SHALL CONFIRM MINIMUM SEPTIC UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS TANK SIZE AT 1000 GALLONS AND ITS SUITABILITY PRIOR ' TO INSTALLING ANY PORTION OF SEPTIC SYSTEM FOR RE -USE. REPLACE WITH 1500 GALLON ------ - --- - SEPTIC TANK APPROPRIATE TO SITE CONDITIONS IF NOT SUITABLE ALARM AND CONTROL PANEL 70 BE INSTALLED INSIDE SYSTEM DESIGN: BUILDING. ALARM TO BE ON SEPARATE CIRCUIT FROM PUMP_ n GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 3 BEDROOMS @ 110 GPD = 330 GPD USE A 330 GPD DESIGN FLOW SEPTIC TANK: 330 GPD (2) = 660 USE EXISTING 1,000 GALLON TANK AND ADD 1,000 GALLON PUMP CHAMBER LEACHING: 4.72 SF/LF x 4' LENGTH = 18.88 SF PER QUICK4 PLUS STANDARD LP UNIT 330 GPD/0.74 GPD/SF = 446 SF LEACHING REQ'D 446 SF/18.88 SF/UNIT = 23.6 UNITS THEREFORE, USE GRAVELLESS SYSTEM OF (24) QUICK4 STANDARD LP UNITS IN FIELD CONFIGURATION OF 4 ROWS OF 6 UNITS 24 UNITS x 18.88 SF/UNIT = 453 SF> 446 SF 453 SF (0.74) = 335 GPD (OK) , MA APPROVED DATE BOARD OF HEALTH LICE # 17-432 1 O' SYSTEM PROFILE (NOT TO SCALE) j 4"OSCH40 PVC 6" MIN. SUMP PIPES LEVEL 1ST 2' 12" MIN. INT. DIM. WATERTEST D'BOX I FOR LEVELNESS f 6.13' -- - �_ 5.96 9 6' 6" CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 [2]) LOW PROFILE D' BOX - PROP. WATERTIGHT COVER TO GRADE PROVIDE QUICK DISCONNECT FOR PUMP 6.93' INV. IN 4.88 NO LOW POINTS 1000 GAL. H-10 S/T 2" PRESSURE LINE ---- ALARM ON 600 GAL.+ SLOPE TO DRAIN BACK TO PC FLOAT SWITCH RESERVE 0.25" WEEP HOLES SETTINGS: PUMP ON CHECK VALVE 5 WORKING RANGE 8 MYERS SRM 4 5" SUBMERSIBLE 4/10 HP PUMP PUMP OFF 8" SYSTEM (OR EQUAL) 000 00000 0 000000 0000 0 0 0000 PUMP CHAMBER (NOT TO SCALE) WATERPROOF/WATERTIGHT PROVIDE 102' OF 40 MIL LINER AT� OFF SAS IN AREA SHOWN. TOP AT ELEV. 6.3', BOTTOM AT EL. 2.3't 5' REMOVAL OF UNSUITABLE SOIL REQUIRED AROUND PERIMETER OF LEACHING FACILITY, DOWN TO SUITABLE SOIL LAYER. REPLACE WITH CLEAN MED. SAND, TO MEET SPECIFICATIONS OF 310 CMR 15.255(3) PROP. WORK LIMIT LINE OF STAKED SILT FENCE \ cAl T AAAP(ZW ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. PROVIDE INSPECTION PORTS TO WITHIN 3 OF FINISH GRADE 2% SLOPE REQUIRED OVER SYSTEM/ 7.2' \I, \1, J, 6.32' 0.28' 1 5.65' QUICK4 STANDARD LOW PROFILE UNITS OVERALL DIMENSIONS TO OUTSIDE OF UNITS: 24' X 11.3' (-L-% SLOPE (NO STONE PROPOSED) LEACHING 4.0' 5' FACILITY GROUNDWATER ADJUSTED EL. 1.65' BUOYANCY CALCS: H-10 1000 GAL. PC WEIGHS 8,240 LBS 1.27 x 815 x 5.66 X 62.4 = 3,451 LBS UP (OK) VARIANCES REQUESTED: UNDER MAX. FEASIBLE COMPUANCE 35.405: (1h):REDUCTION IN SEPARATION OF SAS TO ADJ. G.W. FROM 5.0 TO 4.0 2% MIN. SLOPE OVER SYSTEM { I � 4" LOAM &SEED UNDER TOWN OF YARMOUTH HEALTH REGULATIONS: \I/ I 30"t CAP STONE'UNITS TEST HOLE LOGS (3.7):, REDUCTION IN SETBACK, SAS TO BVW (100' TO 70.0') ,�����-\I/ 1/2" x 5 1/4" -_- Fiberglass 9" COVER I-111�I-1I_- Pins ENGINEER: J. ARI, # CRAIG FERRARI, SE 13871 AS 5'MIN. N WITNESS: PHIL RENAUD o i PEASTONE D DATE: 11/28/17 COARSE SAND BACKFILL AGAINST '< MIN/INCH INCH WALL PERC. RATE _ < / D 40 MIL LINER FROM TOP PEASTONE/WALL 11 V CLASS I SOILS _11l., L SM#2A b TO 12 BELOW GRADE KEYSTONE OR EQUAL RETAINING WALL UNITS 18"X8" SET WITH 1" BATTER PER ROW I FIBERGLASS PINS REQ. n' 6"X30" Crushed Rock or Unreinforced Concrete Leveling Pad req. RETAINING WALL CROSS SECTION NOT TO SCALE ... 7-7-7 - 14" 4 ELEV. i 0" 4.8' BEDROOM BEDROOM KITCHEN LIVING ROOM ENCLOSED PORCH FLOOR PLAN -1ST FLOO R NOT TO SCALE BEDROOM I FLOOR PLAN -2ND FLOOR NOT TO SCALE Permit valid for REPAIR ii SEPTIC 5YS14,N1 ONLX, due.to State and Local septic. variances. Board,of Ilealth review and approvol is required for any fullo a additions/rcno%<rtions/,iiierations to sewage facilities and/or structaresldwelling. Yarmouth [Ill I)cpar•tnlent A�'I ROVE��i�� 1k- �2 .Al �asie Date G -W ADJ. DATA: WELL: MIW-29 ZONE: A ADJ: 1.6' 30" 2.3' 120" I I -5.2' GROUNDWATER @ 57" UNSUITABLE SOIL lm �&�� I�llyd{ � mitilil �ham�wPal l Nli Ian mm �6� ll { OF 2 8 1 Z: i L A N I I F It )l A r uu"4' Y"Milli""THA Ph �ll LJ y PREPARED FOR F L Y N N T R OUR Zec"i N 00f M N E E DATE: DECEMBER 1, 2017 REVISED: 12-7-17 (4 TO 3 BEDROOMS & SAS LOCATION) REVISED: 1-2-18 (NOTE VARIANCES) REVISED: 1-12-18 (SAS) Scale:1 "= 20' 0 10 20 30 40 50 FEET off 508-362-4541 Sgoy L fax 508-362-9880 EL I downcape.com 5 D do IO cane engineefing) inc. civil engineers land surveyors 939 Main Street ( Rte 6A) DATE DANIEL A. OJALA, P.E., P.L.S. YARMOUTHPORT MA 02675 17-432 GEHRET.DWG NOTES o� TOP OF WALL 1. DATUM IS NAVD 88 •c/Qt\��Gtote s AT EL. 7.0 2. MUNICIPAL WATER IS EXISTING o� CAP STONE UNITS 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. Q 1/2" x 5 1/4" Fiberglass 4. DESIGN LOADING FOR ALL PROPOSED PRECAST o �� o� Pins UNITS TO BE AASHO H-10 Lewis Lewis pond 5. PIPE JOINTS TO BE MADE WATERTIGHT. Bay N �'odio 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE D WITH Power ?� 310 CMR 15.000 (TITLE 5.) Locus A 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT 13 R°°d m TO BE USED FOR LOT LINE STAKING OR ANY OTHER t Isl°n rn ��JRP..OSE fe° Nantucket 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. !J Sound _ 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING LOCUS MAP DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD SCALE 1 "=2000't UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL ASSESSORS MAP 15 PARCEL 24 BE REMOVED BENEATH AND 5' AROUND THE PROPOSED LEACHING FACILITY. LOCUS IS WITHIN FEMA FLOOD ZONE AE; 100 12. EXISTING LEACHING FACILITY SHALL BE PUMPED YEAR FLOOD -ZONE EL: 11 ) AS -SHOWN -ON -- AND REMOVED OR PUMPED AND FILLED WITH CLEAN COMMUNITY PANEL #25001 CO588J DATED SAND. 7/16/2014 13. ALL EXISTING MATERIAL AND/OR EQUIPMENT FOUND IN GOOD CONDITION SHALL BE REUSED WHERE EVER SUITABLE PER OWNER. 14. INSTALLER TO VERIFY THE ELECTRICAL SYSTEM IS SUITABLE FOR PUMP CONNECTION. ELECTRICAL PERMIT REQUIRED. (1h):REDUCTION IN SEPARATION OF SAS TO ADJ. G.W. FROM 5.0 TO 4.0 2% MIN. SLOPE OVER SYSTEM { I � 4" LOAM &SEED UNDER TOWN OF YARMOUTH HEALTH REGULATIONS: \I/ I 30"t CAP STONE'UNITS TEST HOLE LOGS (3.7):, REDUCTION IN SETBACK, SAS TO BVW (100' TO 70.0') ,�����-\I/ 1/2" x 5 1/4" -_- Fiberglass 9" COVER I-111�I-1I_- Pins ENGINEER: J. ARI, # CRAIG FERRARI, SE 13871 AS 5'MIN. N WITNESS: PHIL RENAUD o i PEASTONE D DATE: 11/28/17 COARSE SAND BACKFILL AGAINST '< MIN/INCH INCH WALL PERC. RATE _ < / D 40 MIL LINER FROM TOP PEASTONE/WALL 11 V CLASS I SOILS _11l., L SM#2A b TO 12 BELOW GRADE KEYSTONE OR EQUAL RETAINING WALL UNITS 18"X8" SET WITH 1" BATTER PER ROW I FIBERGLASS PINS REQ. n' 6"X30" Crushed Rock or Unreinforced Concrete Leveling Pad req. RETAINING WALL CROSS SECTION NOT TO SCALE ... 7-7-7 - 14" 4 ELEV. i 0" 4.8' BEDROOM BEDROOM KITCHEN LIVING ROOM ENCLOSED PORCH FLOOR PLAN -1ST FLOO R NOT TO SCALE BEDROOM I FLOOR PLAN -2ND FLOOR NOT TO SCALE Permit valid for REPAIR ii SEPTIC 5YS14,N1 ONLX, due.to State and Local septic. variances. Board,of Ilealth review and approvol is required for any fullo a additions/rcno%<rtions/,iiierations to sewage facilities and/or structaresldwelling. Yarmouth [Ill I)cpar•tnlent A�'I ROVE��i�� 1k- �2 .Al �asie Date G -W ADJ. DATA: WELL: MIW-29 ZONE: A ADJ: 1.6' 30" 2.3' 120" I I -5.2' GROUNDWATER @ 57" UNSUITABLE SOIL lm �&�� I�llyd{ � mitilil �ham�wPal l Nli Ian mm �6� ll { OF 2 8 1 Z: i L A N I I F It )l A r uu"4' Y"Milli""THA Ph �ll LJ y PREPARED FOR F L Y N N T R OUR Zec"i N 00f M N E E DATE: DECEMBER 1, 2017 REVISED: 12-7-17 (4 TO 3 BEDROOMS & SAS LOCATION) REVISED: 1-2-18 (NOTE VARIANCES) REVISED: 1-12-18 (SAS) Scale:1 "= 20' 0 10 20 30 40 50 FEET off 508-362-4541 Sgoy L fax 508-362-9880 EL I downcape.com 5 D do IO cane engineefing) inc. civil engineers land surveyors 939 Main Street ( Rte 6A) DATE DANIEL A. OJALA, P.E., P.L.S. YARMOUTHPORT MA 02675 17-432 GEHRET.DWG