Loading...
HomeMy WebLinkAboutEngineered Plans - 2018Wells not shown exceed 150' from the proposed SAS I BENCHMARK: EI. 43.3 (Assumed Datum) i PUMP &REMOVE ' EX/ST/NG LEACH PI 7' Garage Slab 1 8 CONTAMINATED SOLS i i wlTH/N 5' OF PROR SAS i I 50.1 50 49 47 46 45 44 i PROPOSED LEACHING AREA • .�► J I -� S 84 56'10" E 125.55' � 25 0' X 12.8'X Z. 0' (H -/o) IPavedl Drivel 4 .9 _ 43 _ 2 4 43 -'-- - I ::.:. • .1. t X443_ 44– – — 6) cv°: �� ` / o` a w � s Deed: Book 29961, Page 164 Lzj o \ \�:s... a 42 3" Plan: Book 165, Page 75, Lot 3 21 �� 44 \ 43.4 B M 18 X Bedrm mc, Bedrm Laundry Bath 3 . :.::43.4 / .:::.• � a49.0 .. Ij /44.4 I 43.4 :::::;:_:.•::�..r:): ::::...150.0 F)f:•./€: —os i :.•:::...::.: FF�y — w ----W - — w 45. :.. N $_J 44L 49.7 Wood 45.3 1�50:IZ O Existing Deck ll 44 r Dwelling i 41 44.2 X Bedrm mc, Bedrm Laundry Bath LEGEND Existing Building Edge of Pavement/Driveway 50 — Existing Contour r�__�� Existing Septic Tank 0 LOT 3 49.6 TOF ® EI. 50.45 3 2ND FL00 R Existing Leach Pit I Slab ® EI. 43.3 45.1 - :Ir, � •: 12,446.8 SF t o o r ----� Proposed Leaching Area: :.TWO a'_ ::1 0.29 AC t / Entry i i 0 o L____J 25.0'L x 12.8'W x 2.0'D 0 49.5 52.7 Existing Spot Elevation 45.0 ` o Dining Living I 00 - ( \ �I Cn Rm Rm — - OHU - - Overhead Utility Lines O / 44.5 w - — Existing Water Line v I i a� / / l 45.5 1 45.0 45 Family Fence Line ON Kitchen Bedrm y / / Rm Bath to Septic Test Hole ONO •: 1 l `� Sun 49.0'F419 _ 47.4 Rm 9 _ x —A5.2 x Catch 1 19. 9 1ST FLOOR 48 N 84'56' 10" SITE AND SEWAGE PLAN ® I � Basin j' __— i 47 48 I 4outh sDBJecr:arHealth Department PUMP 8 RETA/N EX/ST/NG APP VED /500 -GALLON POLY SEPTIC TANK a am�e Date 4�N or i�1gs ��a�,A�zh of �ass�c.:> MICHAEL =L/ Finished Storage Utilities Entry & Garage Laundry 948 West Yarmouth Road Yarmouth Port, MA PREPARED FOR David Arsenault & Theresa Thistle ASSESSORM, MMT - 115/38 1 of 2 DATE PROJECP: 1/22/18 18-003 SCALE 1°=20' J. �� RICHARD LA:DUE4 J No. 37560 � BASEMENT 0 20 40 60 �, ., Moran Engineering Associates, LLC `$ �0 SS,o EXISTING FLOOR LAYOUT 941 Route 28 N PO Box 183 gk1rA� �a South Harwich, MA 02661 ® 2018 Moran Engineering Associates, «c 508-432-2878 ELEV. 43.5 42.7 40.5 33.4 EXISTING SEPTIC TANK TOP of 1500 GALLON POLY EL 45.Of FOUNDATION -711-I1t'-IIr1lr-1 l r 1 r-„Wrr4IN"1 �.. ... �.. ... ... ... .. 55.0.455 COVERS (2) TO BE WITHIN e' aF GRADE MIN. 9' COVER MAX 36' COVER EXISTING below slab EXISTING ,o- I 1; EL 42.3 1Gi 500 4,� nsrAu BAITLE -71 22'f SEPTIC TANK NOTES I 1. Replace tees 9 corroded. Extend Wet tee 10" min. below flow line; extend outlet tee 14' below flow line. 2. Provide 20" manholes over center of tank, inlet and outlet with readily removable impermeable covers. 3. Install access port over inlet and outlet with precast concrete or equivalent watertight riser within 6" min. of final grade. 4. REPLACE / RESET EXISTING POLY RISERS DATE: 1/17/18 TFST HOLE i1 TEST Bx RICK JUDD TIME: 3:00 PM ' S,�c. NOR. TEXTURE OR SOIL (MUNSELL) MOTTLING STRUCTURE CONSISTENCY, OTHER 10' HTM Fig NO 36' Bwb Loamy Medium Send 7.5 YR 416 NO Massive, Very Friable 127 C Fine to Medium Sand 10 YR 614 NO Loose, Single Grain Sot. of Perc: 56' (C Layer) RATE: < 2 MINANCH, CLASS I SOIL LOADING RATE: 0.74 GPD/SF WITNESS: A Von Hone, H.A., Yarmouth Health Department 0 2018 Moran Engineering Associates, LLC IEL 42.1 1 6't "Q"---%& LEACH FACILITY H-10 500 GALLON DRY WELLS (H-10) EL 44.3± MIN 2% SLOPE ACCESS PORT To WITHIN 6' MIN. 9' COVER OF FINAL GRADE MAX 36"COVER - .. EL 41.3 411=3 EL 41.5 EL 40.5 ELc O O O O O EL 38,5 4,�' 3/4' TO 1-1/2' DOUBLE WASHED STONE W BOX NOTES 1. When system is dosed or slope of inlet pipe exceeds 0.W1IL install inlet tee cut-off one inch above outlet invert. 2. Install outlet pipes level 2 feet minimum. 3. Provide a minimum sump of 6" below outlet invert. 4. Install access port over "D' Bou with precast concrete or equivalent watertight riser within 6" min. of final grade. DESIGN DATA 1. REQUIRED FLOW M BEDROOMS X 110 GPD/B.R. 330 GPD 2. SEPTIC TANK CAPACITY 330 GPD X 2= 660 GPD RETAIN EXISTING 1500 GAL POLY SEPTIC TANK 3. LEACH FACILITY DESIGN: SIDE WALL AREA: 2 (25.0 + 12.8) X 2 X 0.74 = 111.8 BOTTOM AREA: 25.0 X 12.8 X 0.74 = 236.8 TOTAL: 348•6 348.6 GPD PROVIDED > 330 GPD REQUIRED USE: *(2) 500 -GALLON DRY WELLS (HAD) WITH 4.0' OF STONE ALONG SIDES & ENDS 25.0' OVERALL LENGTH INSTALLED INSTALL ACCESS PORT OVER LEACH CHAMBERS W/PRECAST CONCRETE (OR EQUIV.) WATERTIGHT RISER WITHIN 3" (MIN.) OF FINAL GRADE ACCESS PORT - 1 2- LAYER OF 1/8 - TO /8'TO 1/2' DOUBLE WASHED STONE STONE EL 33.4 NO WATER ENCOUNTERED EFFECTIVE DEPTH OD OFF BOTTOM TEST HOLE 1 GENERAL NOTES 1.) ALL SYSTEM COMPONENTS SHALL BE INSTALLED IN ACCORDANCE W/TITLE 5 OF THE SANITARY CODE & ANY APPLICABLE REGULATIONS. 2.) PRIOR TO BACK FILLING THE INSTALLATION, THE DESIGNER & HEALTH AGENT SHALL BE NOTIFIED FOR INSPECTION. 3.) ANY ALTERATIONS OF THIS DESIGN MUST BE APPROVED BY THE DESIGNER & BOARD OF HEALTH, IN WRITING. 4.) SYSTEM IS NOT DESIGNED FOR A GARBAGE GRINDER. 5.) THE INSTALLER IS TO VERIFY THE LOCATIONS) OF UTILITIES, CESSPOOL(S) AND SEWER INVERTS PRIOR TO CONSTRUCTION. 6.) ALL UNSUITABLE MATERIAL WITHIN 5 FT. IN ALL DIRECTIONS FROM THE SOIL ABSORPTION SYSTEM SHALL BE REMOVED & REPLACED W/CLEAN, COARSE SAND. 7.) ALL FILL MATERIAL UTILIZED FOR THE SOIL ABSORPTION SYSTEM SHALL BE CLEAN, COARSE SAND FREE FROM DELETERTOUS MATERIAL AND SHALL HAVE A PERCOLATION RATE OF LESS THAT 2 MIN ./IN. BEFORE & AFTER PLACEMENT. 8.) EXISTING CESSPOOL(S) TO BE PUMPED AND BACK FILLED PER TITLE 5 ABANDONMENT PROCEDURES. 9.) DURING INSTALLATION, THE CONTRACTOR IS RESPONSIBLE TO PROVIDE A SAFE EXCAVATION AREAL 10.) GROUND COVER OVER SEPTIC SYSTEM COMPONENTS SHALL NOT EXCEED 36". 11.) ALL GRAVITY SEWER PIPE SHALL BE 4" DIA. SCH 40 PVC UNLESS OTHERWISE NOTED. THE MINIMUM SLOPE OF 4" DIA. SCH 40 PVC SHALL NOT BE LESS THEN 0.01 FrA T. 12.) WFIEREVER SEPTIC LINES CROSS WATER SERVICE LINES OR WHEN WATER SERVICE LINES COME WITHIN 10' OF THE PROPOSED S.A.S.- PIPES SHALL BE CLASS 150 PRESSURE PIPE & SHOULD BE PRESSURE TESTED TO ASSURE WATER TIGHTNESS. COORDINATE WITH LOCAL WATER DEPARTMENT. 13.) PLACE MAGNETIC MARIGNG TAPE OVER ALL COMPONENTS. S 1 T E AND S E WAGE PLAN - CONTACT OFFICE (508-432-2878) A MINIMUM OF 48 -HOURS PRIOR TO START OF PROJECT. - EXISTING SEWER ELEVATION IS TO BE VERIFIED PRIOR TO THE INSTALLATION OF NEW SYSTEM COMPONENTS. - EXISTING SEPTIC TANK IS TO BE PUMPED 81 RETAINED. RESET SEPTIC TANK RISERS AND COVERS TO FIT EXISTING SEPTIC TANK PROPERLY. BOLT OR SCREW INLET AND OUTLET COVERS TO SEPTIC TANK RISERS. EXISTING LEACH PIT IS TO BE PUMPED AND REMOVED ALONG WITH ALL CONTAMINATED SOILS WITHIN 5' OF THE PROPOSED SAS. - DESIGN ENGINEER IS TO VERIFY SOILS OF ALL SAS EXCAVATIONS BEFORE SYSTEM INSTALLATION. - DESIGN ENGINEER IS TO VERIFY SYSTEM INSTALLATION (LOCATIONS AND ELEVATIONS) PRIOR TO BACKFILLING. - COMPONENTS ARE TO BE WITHIN 3' OF FINISH GRADE AND ARE TO HAVE A MINIMUM OF I' OF SOIL COVER. ACCESS MANHOLES ARE TO BE WITHIN 3'-6' OF FINISHED GRADE. - ALL POST CONSTRUCTION LANDSCAPING DETAILS ARE TO BE BETWEEN INSTALLER AND PROPERTY OWNER OR AGENT. 948 West Yarmouth Road Yarmouth Port, MA David Arsenault & Theresa Thistle) 115/38 1 2 of 2 1/22/18 1 18-003 Moran Engineering Associates, LLC 941 Route 28 N PO Box 183 South Harwich, MA 02661 508-432-2878