HomeMy WebLinkAboutEngineered Plan - Rev. 2018TOP OF FOUNDATION ELEV. = 105.71 -\ ELEV. = _ 102.96 TANK ELEV. = 102.69 4" CAST IRON PIPE (OR EQUAL MINIMUM PITCH 1/4' PER FT. DESIGN CALCULATIONS COVER TO BE WITHIN 6" OF FINISHED GRADE CONCRETE COVERS 9" MIN. COVER TYP. n n 10" MIN. 4'-0" LIQUID LEVEL 1500 GALLON SEPTIC TANK H10 STRENGTH S.A.S. COMPONENTS 3 ROWS OF 8 INFILTRATOR CHAMBERS W/END CAPS WITH CLEAN MEDIUM SAND BETWEEN, AROUND & FOR 6" ABOVE LEGEND: DESCRIPTION EXISTING SPOT ELEVATION EXISTING CONTOUR FINAL SPOT ELEVATION FINAL CONTOUR SOIL TEST LOCATION UTILITY POLE TOWN WATER CATCH BAS I N GAS LINE FIRE HYDRANT SYMBOL Ox 00 ox o0 Ox 00 = W IN = G G I DEPTH EXISTING 2 BEDROOM DWELLING TEXT USE MIN.: 2-3/8" HOLES 104.73 DESIGN 3 x BEDROOMS x 110 GPD/BEDROOM 330 GAL./DAY 102.52 SAS INSP. PORT TOTAL ESTIMATED FLOW 330 GAL./DAY SOIL TEST LOAMY MED/ GARBAGE DISPOSAL UNIT NO ELEV. 101.19 DATE OF SOIL TEST 11/9/17 REQUIRED SEPTIC TANK CAPACITY .10YR4/6' 5.79 WITNESSED BY AMY von HONE 26-120' 200% x 330 CONCRETE 4 CHAMBER FIELD 4" SCHEDULE 40 PVC PIPE INSPECTION PORT BETWEEN, AROUND AND FOR " COVER GAL. SOIL EVALUATOR DAN CROTEAU S13772 MIN. PITCH 1/8" PERADS ACTUAL SIZE OF SEPTIC TANK 1500 _ GAL. LEACHING AREA REQUIREMENTS REPAIR PERCOLATION RATE <2 MIN./INCH. 330/0.74 S.F./GAL = 445.9 S.F. MANHOLE -----COUPLING �1-IMM WTI 11 oi= LEACHING: OBSERVATION HOLE 1 AREA - INFILTRATOR : CHAMBER 4" PERFORATED PIPE INSIDE CHAMBER 105 40 ELEV.=--- - 3 X 32 LF OF CHAMBER X *4.73SF/LF= 454 SF CAPACITY - 454 SF X 0.74 GAL/1 SF= 336 GAL *PER MASS. DEP CERTIFICATION FOR GENERAL USE RESERVE LEACHING CAPACITY 100% S.A.S. COMPONENTS 3 ROWS OF 8 INFILTRATOR CHAMBERS W/END CAPS WITH CLEAN MEDIUM SAND BETWEEN, AROUND & FOR 6" ABOVE LEGEND: DESCRIPTION EXISTING SPOT ELEVATION EXISTING CONTOUR FINAL SPOT ELEVATION FINAL CONTOUR SOIL TEST LOCATION UTILITY POLE TOWN WATER CATCH BAS I N GAS LINE FIRE HYDRANT SYMBOL Ox 00 ox o0 Ox 00 = W IN = G G `TANK 102.44 y - ELEV. _ 14, L EL D -BOX 10234 ELEV. _ 102.17 . . ELEV. - ELEV. = 102.15. cAs BAFFLE DISTRIBUTION BOX TO BE WATER TESTED H10 STRENGTH 16" STONE ON NATIVE GROUND OR MECHANICALLY COMPACTED BASE SEWAGE DISPOSAL SYSTEM PROFILE I NOT TO SCALE I LOT 8 2 8,786 SQ. FT. f 10.20 ACRES 375.72 PERIMETER I WORK SHOP BASH OFFICE AREA UP FURN I DEPTH HORIZ TEXT USE MIN.: 2-3/8" HOLES 104.73 0-8" A 102.52 SAS INSP. PORT DETAIL 103.23 00000 0 ac o o cooco 0 0000000 0000 SOIL TEST LOAMY MED/ 0000c 00000cc000 c0000000000o ELEV. 101.19 DATE OF SOIL TEST 11/9/17 9' x 32' STONELESS .10YR4/6' 5.79 WITNESSED BY AMY von HONE 26-120' USE CLEAN MEDIUM SAND CONCRETE 4 CHAMBER FIELD 4" SCHEDULE 40 PVC PIPE INSPECTION PORT BETWEEN, AROUND AND FOR " COVER 4"PVC PIPE SOIL EVALUATOR DAN CROTEAU S13772 MIN. PITCH 1/8" PERADS 6 ABOVE CHAMBERS REPAIR PERCOLATION RATE <2 MIN./INCH. 3' MAX. MANHOLE -----COUPLING �1-IMM WTI 11 oi= EL.=_105.0 t' MIN. OBSERVATION HOLE 1 COVERjr! �� qu�u�u�u-m�uiu�a�u- INFILTRATOR : CHAMBER 4" PERFORATED PIPE INSIDE CHAMBER 105 40 ELEV.=--- - `TANK 102.44 y - ELEV. _ 14, L EL D -BOX 10234 ELEV. _ 102.17 . . ELEV. - ELEV. = 102.15. cAs BAFFLE DISTRIBUTION BOX TO BE WATER TESTED H10 STRENGTH 16" STONE ON NATIVE GROUND OR MECHANICALLY COMPACTED BASE SEWAGE DISPOSAL SYSTEM PROFILE I NOT TO SCALE I LOT 8 2 8,786 SQ. FT. f 10.20 ACRES 375.72 PERIMETER I WORK SHOP BASH OFFICE AREA UP FURN ELEV. I DEPTH HORIZ TEXT USE MIN.: 2-3/8" HOLES 104.73 0-8" A 102.52 SAS INSP. PORT DETAIL 103.23 00000 0 ac o o cooco 0 0000000 0000 B LOAMY MED/ 0000c 00000cc000 c0000000000o ELEV. 101.19 9' x 32' STONELESS .10YR4/6' 5.79 95.40 26-120' C HIGH CAPACITY INFILTRATOR QUICK 4 CHAMBER FIELD BOTTOM OF TEST HOLE ELEV. _ 95.40 _ ELEV. I DEPTH HORIZ TEXT COLOR MOTTLING" 104.73 0-8" A LOAMY SAND 10YR3/2 - NONE 103.23 8-26" B LOAMY MED/ COARSE SAN .10YR4/6' 95.40 26-120' C MEDCOARSE SAN 10YR5/6 HIGH CAPACITY INFILTRATORS NO WATER AT_ 120" EL. -?122 QUICK 4 CHAMBER FIELD PERI. AT 40" = 102.0' i 1El I' 105.79 EXISTING SYSTEM 0 0' U 0 w J 105.6 05.4 LA HT1 N 24'-" � ®104.86 rn 10 9' 105.12 - 10P99.00 0.00 % A 98.98 1;04.46 i INV. -10 .96' ; �` o I l x z �zwl LA o o�z N U1 Z.al i � i oo ' a J II FJ ' 05.3 1�E F 98.57 W 100.00' " 2' 22, 26 Y ASSESSORS MAP: 86 NOTES- PARCEL: 146 1) SEPTIC SYSTEM TO BE INSTALLED ACCORDING TO 310 CMR 15.000 TITLE 5 AND THE TOWN OF _YARMOUTH__ RULES AND REGULATIONS FOR THE SUBSURFACE DISPOSAL OF SEWAGE. 2) EXISTING AND FINAL GRADES SHALL REMAIN ESSENTIALLY THE SAME. (UNLESS ELSEWHERE NOTED) 3) ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF WITHSTANDING H-19 9 LOADING. 4) ANY MASONARY UNITS USED TO BRING COVERS TO GRADE SHALL BE MORTARED IN PLACE. 5) NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEED RESTRICTIONS OR ZONING. 6) THE INSTALLER IS TO VERIFY THE LOCATION OF UTILITIES AND SEWER LINE ELEVATIONS PRIOR TO INSTALLATION. 7) SOIL ABOVE THE C LAYER (SHOWN ON SOIL LOGS) SHALL BE REMOVED AND REPLACED WITH CLEAN SAND ACCORDING TO MASS. LOCAL SPECIFICATIONS WITHIN 5' AND BELOW THE S.A.S. 8) EXCAVATION FOR AREA WHERE FILL IS REQUIRED SHALL EXTEND 5 FEET LATERALLY BEYOND S.A.S. 9) VERTICAL DATUM ___ ASSUMED______ 10) BENCHMARK T.O.F.=105.71' 1 1) ALL PRECAST UNITS ARE TO BE PLACED ON 6" MIN. CRUSHED STONE MECHANICALLY COMPACTED. 12) GROUND COVER OVER SYSTEM COMPONENTS SHALL NOT EXCEED 3 FEET 13) ALL EXISTING UNUSED COMPONENTS SHALL BE PUMPED, REMOVED AND/OR FILLED WITH CLEAN SAND ACCORDING TO LOCAL REGULATIONS. PLUMBING EXITS REAR OF BUILDING; PIPE AND CESSPOOLS NOT FOUND. 14) CONTRACTOR TO VERIFY ALL PLUMBING IN THE BUILDING FLOWS TO PROPOSED SEPTIC TANK. 15) THIS PROPERTY DOES/DOT FALL WITHIN THE WATER RESOURCE AREA. 16) THIS PROPERTY FALLS IN FLOOD ZONE CLASSIFIED "OTHER" AS SHOWN ON MAP NO. _25001CO583J __-_ DATED JULY 16L2014 17) PLAN REFERENCE PL. BK. 22 0 PG. 14 9 Yarmouth Health Department (LOT 82) PPR-OVD Name Da SITE PLAN SHO WING EXISTING & PR 0 P 0 SED SEPTIC SYSTEM IN YARMOUTH, MA SSA CHUSE T TS AS PREPARED FOR MA UREEN BR 0 WN �i a 4 APPROVED: BOARD OF HEALTH DATE AGENT 57 WEBBER' S PATH PAUL E. S WEE TSER PROFESSIONAL LAND SURVEYOR JOSEPH J. B OR GESI PROFESSIONAL ENGINEER P.O. BOX 1146 DENNISPOR T, MA 02639 (508) 394-4924 REVISIONS- DATE NOV. 24, 2017 FEB. 12, 2018 SCALE 1"=20' FILE NO. 2299-00 SHEET > OF 1