Loading...
HomeMy WebLinkAboutEngineered Plan - 20184 LOCATION MAP LOT 60 (10,333 SF) ASSESSORS MAP: 39 PARCEL: 151 PLAN BOOK: 149, PAGE: 95 BUOYANCY CALCULATION: 1000 GALLON PUMP CHAMBER 8.5'x 4.83'x (99.1 - 95.5) x 62.4 LB/CF = 9,223 LB WEIGHT OF SOIL OVLR4TANK = 4,105 LB A r � 1 105.1 x 105.4 �rN, 5 24" oak rti P y", �� 105.2 S / 1 (0_ 1 'j 25 12"862`k t `� 'th-1 .�� "1105 105 SEPTIC SYSTEM DESIGN SEPTIC SYSTEM SECTION FLOW ESTIMATE: 3 BEDROOMS AT 110 GAL / DAY = 330 GAL / DAY 103.64 aFOUNDATION TOP OF SEPTIC TANK: 330 GAL / DAY x 2 DAYS = 660 GAL 1/8" per ft. USE 1000 GALLON SEPTIC TANK (EXISTING) a 1 .1_ AS SHOWN (35'x 9'x 8" DEEP) SIDE AREA: NA (0.74) = NA GAUDAY BOTTOM AREA: 4'x 24 UNITS x 4.7 = 451 SF (0.74) = 334 GAUDAY CAPACITY = 334 GAUDAY REQUIRED VARIANCES FROM TITLE FIVE: 1. SECTION 15.212: LEACH AREA TO BE LESS THAN V ABOVE GROUND WATER (VARIANCE OF 1.0'), 2. SECTION 15.211 (1): LEACH AREA TO BE LESS THAN 20' FROM CELLAR WALL (VARIANCE OF 3'). 3. SECTION 15.211 (1): LEACH AREA TO BE LESS THAN 10' FROM LOT LINE (VARIANCE OF 3'). 40 MIL POLY LINE 74'x 2' DEEP TOP OF LINER =104.2 BOTTOM ELEVATION = 102.2 s 6h 'f- of-IjS Off. O/A HORIZON ELEV. �o�y�Fo�.y� f�ao��'CO2i ;•.o e 703 \/ ' 12" oak \ hydrant ,^; 18" oak 104 -.-...ice,-• �,�` � A 510 x C) C e� \ 03-.,' ; KEY: EXISTING CONTOUR: PROPOSED CONTOUR: ------------- EXISTING SPOT ELEVATION: 25.5 PROPOSED SPOT ELEVATION: 25.5 TEST HOLE: * UTILITY POLE: -p- FENCE LINE: HYDRANT: RETAINING WALL: m M17-73 F \ t 102 EXISTING FLOWDIFFUSORS (SEE NOTE 13) (EXISTING) ELE\ 100.35 a ELEV. 1000 GAL SEPTIC TANK TEE SIZES: (TO BE CONFIRMED) INLET: 6" UP, 13" DOWN OUTLET: 6" UP, 14" DOWN ELEV. 1[-bh] BED LIVING ROOM ROOM 2" PRESSURE LINE TO EXIT THROUGH RISER OR TANK. A QUICK DISCONNECT IS TO BE PROVIDED FOR FUTURE ACCESS TO PUMP. PUMP CHAMBER COVER TO BE AT GRADE. ALL OTHER COVERS AND INSPECTION PORT TO BE WITHIN 6" OF GRADE. TEE AT INLET 2" pressure , q1/8' per 104.02 103.85 ELEV. ELEV. D -BOX 95.5 / 1000 GAL\ (6" OF STONE UNDER) ELEV. PUMP CHAMBER WITH MYERS SRM -4 PUMP. PUMP ALARM PACKAGE TO BE INSTALLED IN DWELLING POWERED BY CIRCUIT SEPARATE FROM THE PUMP POWER. (DISTANCE BETWEEN ON/OFF SWITCH TO BE 3") (DISTANCE BETWEEN ON SWITCH AND ALARM TO BE 12") DECK KITCHEN BED BED ROOM ROOM BATH EXISTING FLOOR PLAN - BENCHMARK AT RIGHT CORNER OF BOTTOM BRICK STEP ELEVATION = 102.95 TERRY °s o AN 102 WARNER /I -oma No. 38721 roNq o Pcrmiit 'valid. for REPAIR OF 5E1'"fl( Sti S 1 EMi1 aNLY,, due t0 St'ttp and Local scphi tnriances. Iloafd;of Ilealth review and a prov �l is ivyu:uvd for any future `addtt ons/renovations/a It era tion to sewa a a61ities4nd/or strucluaes/dwethng. Yara°lotith Hralkh 1)eparttn{I�t �` � WED APR 0 2018 HEALTH DEPT.. Date 1/4" DRAIN HOLE -CHECK VALVE TEST HOLE LOGS ENGINEER: THOMAS MCLELLAN, P.E. WITNESS: AMY VON HONE, R.S. DATE: 1-18-18 PERCOLATION RATE: < 2 MIN/IN USGS GROUND WATER ADJUSTMENT: WELL: MIW-29, ZONE: B, ADJ. (DEC): 2.6' ADJUSTED GROUND WATER ELEV.= 99.1 INSPECTION PORT /- ELEV. 104.19 T MAX. COVER (1' MIN) .LEV• ELEV. 35'x 9' USE 24 INFILTRATOR QUICK 4 PLUS 4' STANDARD CHAMBERS AS SHOWN (35'x 9'x 8" DEEP) ADJUSTED GROUND WATER ELEVATION = 99.1 kAAAj TH-1 105.0 O/A HORIZON ELEV. LOAMY SAND 81, 10YR 3/3 104.3 B HORIZON LOAMY SAND 30" 10YR 5/8 102.5 C HORIZON BOTTOM OF MEDIUM SAND PERC AT 36" 2.5Y 7/6 OBSERVED 965 1020 120" 95.0 NOTES: 1. VERTICAL DATUM: ASSUMED 2. MUNICAPAL WATER IS AVAILABLE. 3. SCHEDULE 40 - 4" PVC PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM. 4. ALL PRECAST UNITS SUBJECT TO TRAFFIC LOADS TO CONFORM WITH AASHTO H-20 SPECIFICATIONS. 5. PIPE PITCH = 1/8" PER FOOT (UNLESS NOTED OTHERWISE). 6. FIRST 2' OF PIPE OUT OF D -BOX TO BE SET LEVEL. 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARBAGE DISPOSAL. 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE STATE OF MASS. ENVIRONMENTAL CODE (TITLE FIVE) AND LOCAL HEALTH REGULATIONS. 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. 10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT TO EXCEED 3' WITHOUT VARIANCE. 11. FIELD SURVEY PROVIDED BY TERRY A. WARNER, P.L.S., HARWICH, MA. 12. THIS PLAN REQUIRES THE REVIEW AND APPROVAL OF ONE OR MORE TOWN DEPARTMENTS AND IS SUBJECT TO CHANGE UNTIL SUCH TIME. THIS PLAN HAS BEEN PREPARED FOR THE SOLE PURPOSE OF CONSTRUCTION OF A NEW SEPTIC SYSTEM AND DOES NOT NECESSARILY REPRESENT A FULL DETAILED PROPERTY SURVEY. 13. EXISTING FLOWDIFFUSORS ARE TO BE PUMPED AND FILLED WITH SAND OR REMOVED. 14. D -BOX TO BE WATER TESTED TO ENSURE LEVELNESS AND EQUAL FLOW. 15. AN ELECTRIC PERMIT FOR THE PUMP PACKAGE IS TO BE OBTAINED PRIOR TO CONSTRUCTION. 16. PUMP CHAMBER IS TO BE WATER PROOFED BY MANUFACTURER WITH IPANEX CONCRETE ADDITIVE OR CONSEAL 55. A 6" EZ WRAP IS ALSO REQUIRED. 17.2" SEWER LINE TO BE ENCASED WITHIN A 4" SECTION OF PVC PIPE WHEN WITHIN 10' OF WATER LINE. , ":-, " _ THOMAS J. SITE PLAN LOCATION: 24 BOXBERRY IN., W.YARMOUTH, MA PREPARED FOR: MALCOM MORSE DATE: 1-26-18 SCALE: 1" = 20' BASS RIVER ENGINEERING P E P.O. BOX 1163, EAST DENNIS, MA 02641 508-364-9048