Loading...
HomeMy WebLinkAboutEngineered Plan - 2017ASSESSORS MAP: rnliccLl � �� ►�. /.� FLOOD �Eli2. q_.'!D REFERENCE: - '/59-V - .tX&4 A I b is _\_- Te 01 1 LOCATION MAP t\ TEST HOLE LOSS'" n ��kVA,,� I) The installation shall cornptvith'1'itlt V and Town ofd(iV(�I}C�' Board of SO I L EVALUATOR :W • I lealth Regulations. WI TNESS • 2) The installer shall verify the location o 7utilities, sewer inverts and septic DATE: components prior to installation and seting base elevations. PERCOLAT I ON MT : .e_10''" 1 t 3) All gravity septic piping to be 4 inch S h 40 PVC at 1/8" per foot. The first 1 P. g��� 1' � r ' two feet out of the d -box to the ieach4 shall be level. TH-I TH=2 4) This plan is not to be utilized for propelty line determination nor any other purpose other than the proposed systen installation. I �' 5) All septic components must meet Title specifications. 6) Parking shall not be constructed over H 7) The bounded by 10 septic components. ; ' y� �i property is property corners 8) The property owner shall review design) and property lines. considerations to approve of total 'J -14 design flow and number of bedrooms to be considered for design. Receipt i of payment for the plan and installation` based on the plan shall be deemed C.approval r% of the design flow by the own 9) The leaching r. existing or cesspools sliall be pumped and filled with material per Title V abandonment procedures. T pose within the proposed SAS shall be removed along with contaminated so I and replaced with clean sand per Title V specs. i 10) System components to be 10 feet fromater water line shall be sleeved with 4 inch line. Sewer !fines crossing the 51140 PVC with ends grouted if ' applicable. The proposed SAS is being nstalled below (lie water service ' SEPT f C SYSTEM DESIGN line. The line is to be sleeved as aforemEdoned 11) If a garbage grinder exists it is to be rettioved and maintained in place. and is the responsibility of the owner to ensure such: FLOW ESTIMATE 12) The installer is to take caution in excavation around the gas line if such ' B DROOMS AT ID GAL/DAY/BEDROOM - - 7iO GAL/DAY exists. 13) Tine installer shall verify the location, quntity and elevation of the sewer I lines exiting the dwelling'prior to the ins allation. SEPTIC. TANK 14) This plan is representative only that a systtem can fit on a property meeting f Title V requirements. Y-9-0 GAL/DAY x 2 DAYS - GAL USE ; GALLON ,SEPTIC TANKY�,�flWtr)�j'''j SOIL �iBS RPTION SYSTEM r S I DE AREA: Z -#- L�►. BOTTOM AREA: q275 5 1�G - SEPTIC SYSTEM SECTION X • ? % ! o DAVIDB. l'.j `1 ?jZ✓7 MASON m No. 1066 T,E� GAL SEPT I C TANK '` LMEALTHDEPT IVED. 8 2017 Lj er i IV Q AM 34 �r S(TE AND SEWAGE PLAN LOCATION .. IoI & W ��•��%� Yarmouth Health Dep"nrtmcmt P 121 (� � r U PREPARED. ,.FOR : I Ninme Date A 1 SCALE: DAVID Bi MASON DATE: lO DBC ENVIRONMENTAL DESIGNS EAST SANDWICH MA DATE HEALTH AGENT. ( 508) 833= 2 177: