HomeMy WebLinkAboutEngineered Plan - 2017LOCUS SCALE 1 "=750' 1 � 93.27 93.00 EDGE OF PAVEMENT 14" TP -1 ELEV. 96.0± 96.00 TOP OF FOUNDATION ELEVATION 100.00 94.83 - 36" C1 93.00 LOAMY SAND tOYR 6/6 132" ' ' 85.00 MOTTLING: NONE DATE: OCTOBER 25, 2017 WEEPING: NONE PERFORMED BY ASA MINTZ, PE PERC RATE: <2 MIN./IN. WITNESSED BY: BRUCE G. MURPHY, R.S. SOIL PROFILE NOT TO SCALE 92.61 RISERS TO BE INSTALLED ON IN RTWON CHAMBERS TO TO BE GRADED SUCH THAT EXISTING TANK TO BRING COVERS TO WITHIN 6" OF GRADE / �6" RISER ON D -BOX TO BE BROUGHT TO WITHIN OF GRADE COVER DOES NOT EXCEED 36" PROVIDE SPEED LEVELERS ON OUTLETS ------ 94 ---------- ` 92.27 A--16.60' ` N`89'30'00" W = _ jC 93.47119* + R--385.00' o 80.50' - - y A / -- tt 4 93.46 t 94.71 � , q`7 M x �>0' 92.02 X 96 68 \• z I 96.87 IN RTWON CHAMBERS TO G ROUGHTP 9" MNIMUM 3" OF GRA13E 2" OF j" PEASTONE OR PROVIDE ZABEL 86' OF 4- SCH 40 36" MAXIMUM 8 OZ. NON WOVEN A1800 FILTER KS=0.010 MIN. V OF 4- SCH 40PVC, cEOTExnLE UTILITY POLE S=0.005 MIN. ELEV.=93.25 - TOP CHAMBER TING 1,000 GALLON 14" r(CENTERM SOUTH YARMOUTH, MA 02 364 FORCED CONCRETE___SEPTIC TANI< INV.=96.21 INV.=92.93 _ INV.=92.78 -� -�i= �c _ 10" DEPTH OF Ni - 1 Jr DOUBLE = WASHED CRUSHED STONE WITH GAS BAFFLE ___EXISTING INV. -92.75E J - -- cELEV.=91.92 - BOT FIELD IN TANK OPENING) LEVEL STABLE BASE CONSISTING Q4TE LI4AWINC NO. OF 6" CRUSHED STONE 4' , 34" X 75" LEACHING CHAMBER ( 4' , _ ]- r" (SEE SITE PLAN FOR ORIENTATION) 5' MINIMUM SEPARATION TO EXISTING SEPTIC TANK TO REMAIN PROPOSED 3- OUTLET (4)-H20 INFILTRATORS DISTRIBUTION BOX PROPOSED SOIL ABSORPTION SL SEASONAL HIGH GROUNDWATER ------ 94 ---------- ` 92.27 A--16.60' ` N`89'30'00" W = _ jC 93.47119* + R--385.00' o 80.50' - - y A / -- tt 4 93.46 t 94.71 � , q`7 M x �>0' 92.02 X 96 68 \• z I 96.87 0 -W--- G NATURAL GAS LINE CB Lm 0 HYD � FIRE HYDRANT WG ® WATER GATE VALVE UPS UTILITY POLE 91 BLUE ROCK ROAD SOUTH YARMOUTH, MA 02 364 p I` ANTHONY AND NICOLE BO ERS ORA►NNC n7L£.• SUBSURFACE SEWAGE DISPOSAL SYSTEMFtl 1 SITE PLAN AND PROFILE SG1LE. Q4TE LI4AWINC NO. 1 "=20 11,5/2017 _ ]- 98,291 98 EXISTING 25.66' DWELLING TOF=100.00' t a t w t ! to X 99.27 I I 0 99.20 ISH' I ! ,r o, EXISTING 1,000 GALLON j 24.93' TANK TO REMAIN -- �;�% t:; It DECK i !! AND BE REUSED I I -----X L-------� X 94.94 � �o STI 3 \� ' / 97.13 1, 99.35 � X 11.00' 32.7 GROUNDWATER NOT OBSERVED DURING OBSERVATION HOLES BOTTOM OF TEST HOLE ELEV.=85.00 SITE INFORMATION GENERAL NOTES: 1. THE PROPERTY IS LOCATED IN ZONE X Oj. THE CURRENT FEMA FLOOD MAP ADDRESS: 91 BLUE ROCK ROAD SOUTH YARMOUTH 2. THERE ARE.NO STREAMS OR WETLANDS WI IN 100 -FEET OF THE PROPOSED SYSTEM. ASSESSORS MAP/LOT: 111/04 DEED BOOK/PG 17368/196 3. THIS PLAN IS FOR THE DESIGN AND CONS RUCTION OF THE SUBSURFACE SEWAGE DISPOSAL SYSTEM ONLY DESIGN CALCULCATIONS 4. VERTICAL DATUM IS ASSUMED 5. ALL CONSTRUCTION MEANS AND METHODS 3HALL CONFORM TO 310 CMR 15.00 STATE DESIGN FLOW REGULATIONS AND LOCAL BOARD OF HEAL14 REGULATIONS 110 GALLONS/DAY/BEDROOM X 3 BEDROOMS = 330 GALLONS/DAY 6. ALL JOINTS IN THE TANK AND DISTRIBUTION BOX SHALL BE MADE WATERTIGHT TANK CAPACITY THROUGH THE USE OF ASPHALT OR SYNTHETIC POLYMER SEALERS OR HYDRAULIC 200% DAILY - FLOW = 660 GALLONS; USE EXISTING 1,000 GALLON TANK CEMENT. 7. ALL UTILITIES SHOWN ON THIS PLAN ARE PROXIMATE ONLY AND SHALL BE FIELD REQUIRED LEACHING CAPACITY DESIGN PERC RATE _ < 2 MIN/INCH VERIFIED. DIGSAFE AND LOCAL UTILITY COMPANIES SHALL BE CONTACTED PRIOR TO - 330 GPD / 0.74 GALLONS PER DAY PER SQ. FT. = 445.94 SO. FT. ANY EXCAVATION OCCURRING. 8. THE SEPTIC SYSTEM INSTALLER SHALL NOT' PROVIDED LEACHING CAPACITY BEGINNING INSTALLATIONOFTHE SYSTEM T0 � THE DESIGN ENGINEER 2 DAYS PRIOR TO ALLOW FOR SCHEDULING OF INSPECTIONS _ 91'91 BOTTOM _AREA = 36.00 X 11.00 = 396.00 SO. FT. - - _ - _ - r f 9. THE EXISTING TANK SHALL BE REUSED. THE EXISTING OtS1T21BUlI0N BOX AND SIDE 94.00 X 0.83 - -'"- = 78A2 SQ. FT. LEACHING PIT SHALL 8E ABANDONED/REM `VEO AND BACKFILLED WITH CLEAN SAND. 474 02 SQA[, 10. WHERE APPLICABLE, UNSUITABLE MATERIAL (A, 8 AND C HORIZONS) ENCOUNTERED �i SPD PROVIDED = 350.77 GPD BELOW THE INVERT OF THE INLET TO THE SOIL ABSORPTION SYSTEM, SHALL BE REMOVED TO A DISTANCE 5' AROUND THE SYSTEM AND BROUGHT BACK TO THE APPROPRIATE ELEVATION WITH CLEAN SAND PER MASSACHUSETTS 310 CMR 15.00 REGULATIONS. I Yarmouth Health Department II 11. NO PRIVATE WATER SUPPLY WELLS EXIST WITHIN 150' OF THE PROPOSED SYSTEM. LEGEND � ���✓ ��� � (� 12. NO GRAVEL PACKED PUBLIC WATER SUPP WELLS OR SURFACE WATER SUPPLY EXIST ! 1�1 1(31e WITHIN 400' OF THE PROPOSED SYSTEM l PROPERTY LIN Dote t 13. THIS DESIGN DOES NOT ALLOW FOR THE USE OF A GARBAGE GRINDER t - -104 - - EXISTING CONTOURi>rf7-/��k t� I 14. THE ELEVATION OF THE EXISTING OUTLET INVERT OR BUILDING SEWER SHALL BE FIELD ---104 - - - PROPOSED CONTOUR VERIFIED PRIOR TO COMMENCEMENT OF CONSTRUCTION. � I �JX X X X STOCKADE FENCE - 92,18 OHP EXISTING OVERHEAD WIRES zo�56/, EXISTING SEPTIC SYSTEM J !T -1 1 TO BE REMOVED/ABANDONED I T w I (SEE GENERAL NOTES) X 99.63 j` o i y t �� LOT 2 PROPOSED 3 -OUTLET °0 31,168 SQ. FT. t H-10 DISTRIBUTION, , BOX t \) 0.72 ACRES PROPOSED' S.A.S. ! ! (4) H-20 HIGH CAPACITY !� 4" INSPECTION 92.65 ( X 10 3 23 INFILTRATORS WITH 4' OF STONE ROUND PORT (TY; .-BOTH SIDES) t LIMIT OF ,! ! X 92. 3 CRUSHED STONE f EXISTING ! I SHED i X 95.49 \`� � X94, `ro a0% PRO X 98.84 Ty Ll S 79-22'00,, g'�2' CB/DISK(FND) DD" BENCHMARK E 1p0.00' 8 96 ELEV.=100.20' `\ao \ - c: S 89'55'30" W 87.96' - 96 � WATER LINE -W--- G NATURAL GAS LINE CB Lm CATCH BASIN HYD � FIRE HYDRANT WG ® WATER GATE VALVE UPS UTILITY POLE � 4 CRESTVIEW DRIVE EAST SANDWICH, MA 02537 PHONE: (508) 400-2365 f E SITE D SIGN, LLCyw T P%r Resi41nt'l Site Design. and Permitting ' LOC4nON.- 91 BLUE ROCK ROAD SOUTH YARMOUTH, MA 02 364 CL/ I` ANTHONY AND NICOLE BO ERS ORA►NNC n7L£.• SUBSURFACE SEWAGE DISPOSAL SYSTEMFtl 1 SITE PLAN AND PROFILE SG1LE. Q4TE LI4AWINC NO. 1 "=20 11,5/2017 _ ]- II NO. I DATE I I DESCRIPTION I a