HomeMy WebLinkAboutEngineered Plan - 2017/ NKEY: EXISTING CONTOUR: - — — - 4 PROPOSED CONTOUR: •------------ LOCUS EXISTING SPOT ELEVATION: 25.5 PROPOSED SPOT ELEVATION: 25.5 O TEST HOLE: + UTILITY POLE: --c,- FENCE LINE: < HYDRANT: -6- ti RETAINING WALL: ---bv " \ LOCATION MAP PARCEL 203 (11,366 SF) ASSESSORS MAP: 60 PARCEL: 203 PLAN BOOK: 158, PAGE: 155 .........33.5......... LEACH AREA DETAIL SEPTIC SYSTEM DESIGN FLOW ESTIMATE: 3 BEDROOMS AT 110 GAL / DAY = 330 GAL / DAY SEPTIC TANK: 330 GAL / DAY x 2 DAYS = 660 GAL USE 1000 GALLON SEPTIC TANK (EXISTING) LEACHING AREA: USE 3 - 500 GALLON CHAMBERS (8.5'x 4.8'x 2' EFF. DEPTH) WITH T OF STONE AROUND SIDES AND 4' AT ENDS (8.8'x 33.5'x 2') SIDE AREA: (8.8'+ 33.5') x 2 x 2 = 169 SF (0.74) = 125 GAUDAY BOTTOM AREA: 8.8'x 33.5'= 295 SF—(0.74) = 218 GAUDAY CAPACITY = 343 GAL/DAY Permit, valid for Rt.PAlit ')1` {I Elij t C` SA I I IGl pNL Y, due -It State a of Ilcalth review and :,pp�'ova{ is rryuircd for N Soard. any... future additions/rcn„� ation,/:,lterations o sewage facilities andlor strucu„csld�.clling. Yirtaouth IIeaI[h I)cpartn,cnt�: p �tP A P1 O V o, ����ZH OF M,{gS'c�� �° TER6�Y �� WAt4NER A No. 30721 /k M17-44 f� r 5 � °a 100 Ally Ell O, / o0%SOo v coo i G xA G � 12" tree g 3 \ 0 �k'19\N day / � T / N� o N m top `•� \ °Lo. `"o 24" tree \ 0 Pgv� �#a� �. LP / SEPTIC SYSTEM SECTION TION 1000 GAL SEPTIC TANK TEE SIZES: (TO BE CONFIRMED) INLET: 6" UP, 13" DOWN OUTLET: 6" UP, 14" DOWN 2nd FLOOR CONCRETE �'- PATIO BATH DEN T MAX. COVER (1' MIN) D -BOX ` (6" OF STONE UNDER OR MECHANICALLY COMPACTED) ELEV -GAS BAFFLE AT OUTLET TEE TEST HOLE LOGS ENGINEER: THOMAS McLELLAN, P.E. WITNESS: AMY VON HONE, R.S. DATE: 8-10-17 PERCOLATION RATE: < 2 MIN/IN NOTES: 1. VERTICAL DATUM: ASSUMED 2. MUNICAPAL WATER IS AVAILABLE. 3. SCHEDULE 40 - 4" PVC PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM. 4. ALL PRECAST UNITS SUBJECT TO TRAFFIC LOADS TO -CONFORM WITH AASHTO �? KITCHEN H=20 SP 5. PIPE PITCH = 1/4" PER FOOT (UNLESS NOTED OTHERWISE). 6. FIRST 2' OF PIPE OUT OF D -BOX TO BE SET LEVEL. 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARB/ DINING 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE STATE OF MASS. ROOM CODE (TITLE FIVE) AND LOCAL HEALTH REGULATIONS. NS OF ALL UTILITIES PRIOR TO CONSTRUCTION. PEASTONE OR F 3/4"- 1 1/2" DOUE WASHED STONE � INSPECTION H 2'-4' 8.8' x 33.5= 3 - 500 GALLON CHAMBERS WI O 4' AT ENDS E(8.8'Ox 33. ' x 2ED E TH-1 100.0 O/A HORIZON ELEV. VARIANC LOAMY SAND 11. FIELD SURVEY PROVIDED BY TERRY A. WARNER, P.L.S., HARWICH, MA. 12" 10YR 4/2 99.0 TS AND B HORIZON IS SUBJECT TO CHANGE UNTIL SUCH TIME. TH,MA LOAMY SAND 13. EXISTING LEACH PIT IS TO BE PUMPED AND REMOVED. 21" 10YR 5/8 98.3 C HORIZON MEDIUM SAND 2.5Y 7/4 144" 1 188.0 NO GROUND WATER ENCOUNTERED FABRIC 97.83 95.0 ELEV. FICATIONS. DISPOSAL. /IRONMENTAL w, 100 '° 1 ' ,- + 20" tree 100 S g�de`�a\K �' ( 4 G-GlL�1� / 18�tr_ee °eee 100 �p nopz_,2, 7,0 BENCHMARK AT PAINTED MAG NAIL ELEVATION = 100.32 Off' SITE PLAN 9. CONTRACTOR TO VERIFY LOCATIO -------- T_ 10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT TO EXCEED 3' WITHOUT VARIANC sewing 11. FIELD SURVEY PROVIDED BY TERRY A. WARNER, P.L.S., HARWICH, MA. room LIVING FOYER ROOM 12. THIS PLAN REQUIRES THE REVIEW AND APPROVAL OF ONE OR MORE TOWN DEPARTME TS AND IS SUBJECT TO CHANGE UNTIL SUCH TIME. TH,MA 13. EXISTING LEACH PIT IS TO BE PUMPED AND REMOVED. PORCH 14. D -BOX TO BE WATER TESTED TO ENSURE LEVELNESS AND EQUAL FLOW. EXISTING FLOOR PLAN w, 100 '° 1 ' ,- + 20" tree 100 S g�de`�a\K �' ( 4 G-GlL�1� / 18�tr_ee °eee 100 �p nopz_,2, 7,0 BENCHMARK AT PAINTED MAG NAIL ELEVATION = 100.32 Off' SITE PLAN LOCATION: 246 OLD MAIN ST., SNARMO TH,MA / V "c"T, "r ' I \ PREPARED FOR: KEITH & ERIN SMIT nen " X71 "' P t DATE: 8-14-17 SCALE: 1" = 20' AUG 12017 _.9 BASS RIVER ENGINEE ING HEALTH DEP THOMAS P.O. BOX 1163, EAST DENNIS, MA 2641 J. MILE AN, P.E. 508-364-9048