Loading...
HomeMy WebLinkAboutEngineered Plan - 2017LOCUS N 4 PATHRS LOCATION MAP LOT 53 (21,708 SF) ASSESSORS MAP: 89 PARCEL: 64 PLAN BOOK: 280, PAGE: 52 M17-60 KEY: EXISTING CONTOUR: - - - - PROPOSED CONTOUR: ............. EXISTING SPOT ELEVATION: 25.5 PROPOSED SPOT ELEVATION: 25.5 TEST HOLE: * UTILITY POLE: -O- FENCE LINE: - HYDRANT: -6 - RETAINING WALL: o 25.0' ................ N 'm. LEACH AREA DETAIL SEPTIC SYSTEM DESIGN FLOW ESTIMATE: 3 BEDROOMS AT 110 GAL / DAY = 330 GAL / DAY SEPTIC TANK: 330 GAL / DAY x 2 DAYS = 660 GAL USE 1000 GALLON SEPTIC TANK (EXISTING) LEACHING AREA: USE 2 - 500 GALLON CHAMBERS (8.5'x 4.8'x 2' EFF. DEPTH) WITH 4' OF STONE ALL AROUND (25'x 12.8'x 2' DEEP) SIDE AREA: (25' + 12.8') x 2 x 2 = 151 SF (0.74) = 112 GAUDAY BOTTOM AREA: 25'x 12.8'= 320 SF (0.74) =137 GAUDAY CAPACITY = 349 GAL/DAY POINSETTIA DRIVE cc S 86°26'12" E -- -99- LUw 1100 \ PAVED DRIVE W � �. W - - 100 M MM \ T EXISTING GARAGE C> \ c 3 BEDROOM E DWELLING - - -.\ top fnd.= 102.25 101 invert = 99.1 99 a'e \\ p \ \ : 6" spruce 1 N E \4.-S \ E� U ST \ \ ..patio block DECK � �; • !� / 12" pines ^ 24" p th-1 Shed i 100 � pine � \ e \ y..ti � ^h � ry \ 99 CO Allo_ . IV W metal post BENCHMARK AT LEFT CORNER OF A.C. PAD ELEVATION = 100.67 SEPTIC SYSTEM SECTION FIRST FLOOR COVERS WITHIN 6" 102.25 OF FINISHED GRADE TOP OF d FOUNDATION " '"' FINISHED GRAr 3' MAX. 99.1 COVER ELEV. a 97 95 (1' MIN) ING) ELEV. 96.7 296.87 a ELEV.ELEV. D -BOX ELEV. OF STONE UNDER OTED) GAL "14"�'DOWN MECHANICALLY CAL Y COMPAC6" TANK TEE SIZNFIRMED) rivl�, INLET: 96.4 ELEV, OUTLEN ath dining GAS BAFFLE kitchen room AT OUTLET TEE bed Ibed LOCATION: room living IroOn room rivl�, DAVID BLACK bed ath dining room�bath kitchen room DATE: 11-8-17 family room EXISTING FLOOR PLAN garage TEST HOLE LOGS ENGINEER: THOMAS McLELLAN, P.E. WITNESS: AMY VON HONE, R.S. DATE: 11-2-17 PERCOLATION RATE: < 2 MIN/IN Yarirn®nth Health Department APPROVED Na»e Dare Rl P�1'60F14,q S � t TERRY o ANN <. WARNER N '> No.38721 P� PEASTONE OR FI TER FABRIC 3/4" - 1 1/2" DOUBLE HASHED STONE INSPECTION F ORT ,,-- EL. V.= 97.23 lld° ° H 4' -25'x 12.8' 2 - 500 GALLON CHAMBERS WI 4' OF STONE ALL AROUND (25'x 12.8'x 2' DEEP) TH-1 99.0 O/A HORIZON ELEV. LOAMY SAND 10YR 3/1 98.0 B HORIZON LOAMY SAND 10YR 5/8 96.5 C HORIZON MEDIUM SAND PER( 2.5Y 7/4 132"1 1 88.0 NO GROUND WATER ENCOUNTERED NOTES: 1. VERTICAL DATUM: ASSUMED 2. MUNICAPAL WATER IS AVAILABLE. 3. SCHEDULE 40 - 4" PVC PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM. 4. ALL PRECAST UNITS SUBJECT TO TRAFFIC LOADS TO CONFORM WITH AASHTO H-20 SPEC 5. PIPE PITCH = 1/4" PER FOOT (UNLESS NOTED OTHERWISE). 6. FIRST T OF PIPE OUT OF D -BOX TO BE SET LEVEL. 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARBAC 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE STATE OF MASS. E CODE (TITLE FIVE) AND LOCAL HEALTH REGULATIONS. 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. 10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT TO EXCEED T WITHOUT 11. FIELD SURVEY PROVIDED BY TERRY A. WARNER, P.L.S., HARWICH, MA. 12. THIS PLAN REQUIRES THE REVIEW AND APPROVAL OF ONE OR MORE TOWN DEPARTMEI IS SUBJECT TO CHANGE UNTIL SUCH TIME. 13. EXISTING LEACH PIT IS TO BE PUMPED AND FILLED WITH SAND OR REMOVED. 14. D -BOX TO BE WATER TESTED TO ENSURE LEVELNESS AND EQUAL FLOW. SITE PLAN BASS RIVER ENGINEE J.. MCLELLAN, P.E. P.O. BOX 1163, EAST DENNIS, MA 508-364-9048 94.4 ELEV. DISPOSAL. /IRONMENTAL 1 AND 1" = 30' I LOCATION: 87 POINSETTIA DR., S. YARM PREPARED FOR: rivl�, DAVID BLACK v, DATE: 11-8-17 BASS RIVER ENGINEE J.. MCLELLAN, P.E. P.O. BOX 1163, EAST DENNIS, MA 508-364-9048 94.4 ELEV. DISPOSAL. /IRONMENTAL 1 AND 1" = 30' I