HomeMy WebLinkAboutEngineered Plan - 2017SYSTEM PROFILE PROVIDE MIN. 20" DIAM. WATERTIGHT (NOT TO SCALE) ACCESS COVERS TO WITHIN 6" OF FIN. GRADE \ TOP FOUND. EL. 17.2' 15.8' MINIMUM .75'10F COVER OVER PRECAST PRECAST H-10 RISERS (•fYP.) ,• : 2'm 4"4SCH40 PVC a 6" MIN. SUMP PIPES LEVEL 1ST 2' �Y � ' • •� �12" MIN. INT. DIM. 1 p" 1500 GAL H-10 14" ' 13.91 ' TEE SEPTIC TANK TEE 13.66' T0,?'-o0*-00o,,o_0o? o0000oa WATERTEST D'BOX A GAS BAFFLE FOR LEVELNESS13.113.4413.27' a LIQ. LEVEL (ACME OR EQUAL) .': J. V00000000000000OOOOi,00000000000000000000000" 0 I 000001, 0 n 0n0.,0 n 00000 OO 001,01.00 0n0^ 0n 00 000000 *EXISTING PLUMBING IS TO BE RE-ROUTED TO FRONT OF 6" CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 [2]) HOUSE, PLUMBER TO CONFIRM FEASIBILITY PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM. (-1-7. SLOPE) (-1-7.SLOPE) LOW PROFILE FOUNDATION- 13' SEPTIC TANK 22' DBOX 12' (_2_5% SLOPE) LEGEN D 99- EXISTING CONTOUR X 991 EXIST. SPOT ELEV. --[991- PROPOSED CONTOUR 198.41 PROPOSED SPOT EL. TH 1 I fax 508-362-9880 TEST HOLE SLOPE OF GROUND UTILITY POLE ell M �� # Inc. FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR -1N DRAWING TEST HOLE LOGS ENGINEER: DANIEL E. GONSALVES, SE #13587 WITNESS: AMY VON HONE, RS DATE: 12/14/2017 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS ELEV. 0" 13' 0., '4 A SL 12" 12" 10YR 4/2 B SL 40" 1 OYR 5/6 9.7' 16" C 30„ PERC V - M/CS 2.5Y 7/4 84" 6.0' 102" 90" 5.5' 120" FILL A SL 1OYR 4/2 B SL 1OYR 5/6 C MS 2.5Y 7/4 GROUNDWATER ENCOUNTERED EL. 6.0 DCLT #17-350 G -W ADJ. DATA: WELL: M I W 29 ZONE: A ADJ: 1.5' NOV. 2017 ELEV. 14.5' 0 BENCHMARK: CEMENT BOUND =13.9' NAVD88 NOTES_ 1. DATUM IS NAVD 88 MARK CORNERS OF LEACHING FIELD W PROVIDE INSPECTION PORTS TORoute Bake REBAR SET 4" BELOW WITHIN 3" OF FINISH GRADE 2. MUNICIPAL WATER IS EXISTING 28 GRADE 27* SLOPE \ 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. I FILTER FABRIC 4. DESIGN LOADING FOR ALL PROPOSED PRECAST 14.3 TOP 13.54' FINISHED GRADE- 4" LOAM & SEED OR PAVE AS REQ. UNITS TO BE AASHO H-12 m L ocu�s CLEAN FILL 5. PIPE JOINTS TO BE MADE WATERTIGHT. fey ° a oy 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE 4" PERFORATED PVC 3' O.C. S=0,005 - O WITH ' -�° 310 CMR 15.000 (TITLE 5.) 8" 3/4"-1-1/2" DOUBLE WASHED STONE LEACHING FIELD ° 6"DEPTH MIN BELOW INV. m ° 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND LEVEL BOTTOM o 13.0' NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. q'%o Ct n a 0 12.5' 5.0' -- ADJUSTED GROUNDWATER 7.5' LEACHING FACILITY 11 .10' -, OF I < 00% I \ X owl I _ \ / TH2 PROP 7T!SED o AD ITIONA i ECD T a oti SHWR ADDITION X0 DECK // LOT AREAE -ROUTE / ALL EXISTING 15,676 S.F. ❑ / EXISTING DWELLING PLUMBING TO = 17.2 TO FRONT 31.2' X N O N �1 000 13.7' XPAVED 0. 10.0' 315✓ DRIVE 10.1' 14.3 1 12.1' ....,��... \/W L, E_ E OFW 13 10. 23.1 ' 19.2' 2 Ij IJ 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. C, 9. COMPONENTS NOT TO BE BACKFILLED OR Q`•$' CONCEALED WITHOUT INSPECTION BY BOARD OF Bfl Lewis HEALTH AND PERMISSION OBTAINED FROM BOARD y OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE OF ALL UNDERGROUND OVERHEAD UTILITI SATION PRIOR TO COMMENCEMENT OF& LOCUS MAP WORK. SCALE 1 "=�000't 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED BENEATH AND 5' AROUND THE ASSESSORS MAP 36 PARCEL 47 PROPOSED LEACHING FACILITY. LOCUS IS V (THIN FEMA FLOOD ZONE X AS 12. EXISTING LEACHING FACILITY SHALL BE PUMPED SHOWN ON COMMUNITY PANEL #25001 CO569J AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. DATED 7/1 /2014 T < ZONIN SUMMARY ? ZONING DISRICT: R-25 DISTRICT o, MIN. LOT SI E 25,000 S.F. MIN. LOT F `ONTAGE 150' x Q)( MIN. FIR SETBACK 30' MIN. SIDE SETBACK 15' MIN. REAR SETBACK 20' SYSTEM DESIGN. MAX. BUILDI G COVERAGE 25% 1 I GARBAGE DISPOSER IS -NOT ALLOWED_ PROPOSED BUILDING COVERAGE = 10.9% EXISTING 2 BEDROOM DWELLING PROPOSED 3 BEDROOM DEWELLING DESIGN FLOW: 3 BEDROOMS @ 110 GPD = 330 GPD USE A 330 GPD DESIGN FLOW -r2-- SEPTIC TANK: 330 GPD (2) = 660 ` ,� ; �,�s� �''�1,��"��,.rr 7a USE A 1500 GAL. SEPTIC TANK LEACHING- 330 GPD = / (.74) 446 SF REQUIRED 11' X 41' 451 SF OK 451 SF X .74 333 GPD OK USE A 11, X 41, PIPE AND STONE LEACHING FIELD Lr� "I''� CC�r�.i RECEIVED MA �:3 1 ?01� N APPROVED DATE BOARD OF HEALTH HEALTH DEPT. ro� Y rmoeth Hemlth Depart ent �pp yD -Z a Mite 12' / •�• •--... ..�, 50: OFF VW. = \ •� CLE �. AND A y sqc� OJALA A Cf)14 DANIELA. " CIVIL �I 11 12980 No. 46502 q: 0 10 Fromm 01,� S T eR��a`� 6.0 m T''/0 SUR`1E�o� SSNAL 4.5' c A Scale:1"= 20' j 2.1�►- 1`f �---- 0 10 20 30 40 50 FEET DATE DANIEL A. OJALA, P. E., P.L.S. � � G TITLE 5 SITE PLAN I OF #82 CLEVELAND WAY WEST YARMOUTH, MA PR`PARED FOR M/M BUDREAU EMBER 19, 2017 DATE: DE off 508-362-4541 I fax 508-362-9880 downcope.com Nola caps ell M �� # Inc. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOU HPOR T MA 02675 17-350