Loading...
HomeMy WebLinkAboutEngineered Plans - 2006Benchmark set Oran,qe pain t on retaining wall E1.=95.68 (assumed) POLY—LINE( . SET 5' OUTSID S.A.S. AS SHOWN �c ET FROM EL.92.0 to 89,0 MT -f' r " "`'r�-LLL- S PAIN L� r Ii c , t r' S 84-02'1,5" E __---� 7 150 ' 1 l i -' 1OWN WATER SERVICE PRO14DED FROM 1 ` ROM MAIN ON MICHELL'S PATH 3. • --ry� - X W. L'I"Z217 Permit valid for AEMA49 bF SEPTI—C-37STCM ONLY, due to State and Local septic variances. Board of Health review and approval is rF"ired for any future additions/renovations/alterations to sewage facilities and/or structures/dwelling. Yarmouth Health Department 'PROVED,2�W1L' ZIW4 / �Oma_? ....LL,I �' J EXISTING HOUSE (#39) TOF= 98, 06,. (Assumed) ti t} 1500' N-47582'15" W EXISTING S.A.S.(APPR&) CONTRACTOR SHALL LOCATE, PUMP AND FILL WITH SAND t 77 / f . • • .,. J✓f..t 9 fes/ LOTI 9 1. I 16, 500,+ S, F. _' 0 38f AC Map 76 Parcel 3 EXISTING TANK SCI 3 TOP OF TANK EL.=97.08 INV.(OUT) EL.=96.75± 3 O h to O 7 LEGEND 78Y- PROPOSED CONTOUR 79 PROPOSED SPOT GRADE EXISTING CONTOUR t9 TEST PIT - EXISTING WATER SERVICE -- - G --- EXISTING GAS SERVICE ANNY�� WARNER N No. 38721 wP�1� t}f ��ssq�y o PETER T. MCENTEE v CIVIL No. 35109 X12 JUL 2 5 2006 Town House Rood LOCUS 0 Belts Path 7 O Michelle's Path C 3 Dana's Path Jilts Path a ,11 LOCUS MAP N.T.S. GENERAL NOTES; 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE LOCAL RULES AND REGULATIONS. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. E. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY PROVIDED BY TOWN WATER. 8. THERE ARE NO PRIVATE WELLS LOCATED WITHIN 100' OF THE S.A,S. 9. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR. 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. 11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS IN THE AREA BENEATH AND FOR 5 FT. ON ALL SIDES OF THE S.A.S. AND REPLACE WITH CLEAN FILL AS SPECIFIED IN 310 CMR 255(3). 12. CONTRACTOR SHALL EVALUATE STUCTURAL INTEGRITY OF EXISTING SEPTIC TANK PRIOR TO CONSTRUCTION. PROPOSED SEPTIC SYSTEM UPGRADE 39 MICHELLE'S PATH, YARMOUTH, MA Prepared for: David Barr, 39 Michelle's Path, Yarmouth, MA Engineering by: Surveying by: SCALE DRAWN JOB. NO. EngineeftWorb Terry A. Warner PLS 1 "=20' P.T.M. 187-06 12 West Crossfield Rood 22 Long Rood DATE CHECKED SHEET N0. Forestdole, MA 02644 Harwich, MA 02645 (508) 477-5313 (508) 432-8309 7/22/06 P•T•M• 1 Of 2 T.O.F (EXISTING) /"EXISTING EXISTING (3) 5" DIA.OUTLETS 15.5" 0 B" B" H-10 LOADING 2 D -BOX N.TS 0 ®®®a 0 ®®®® 02®®®®®®®®® 33" ItlW 50 k3_a ®®® ® ® toe 4" KNOCKOUT /\^220" DIA. COVER 4" KNOCKOUT �./ 4" KNOCKOUT 0 4" KNOCKOUT F.G. EL: 97.7±(EXISTING) INSTALL RISERS OVER INLET & OUTLET TO WITHIN 6" OF FINISH GRADE I 500 GALLON CAPACITY, H-10 LOADING CHAMBERS N.LS L =38' „ 4" SCH 40 PVC 10 EXISTING 14" 0 S= 1% (MIN.) 6 1000 GALLON SEPTIC TANK INV. ELEV.=9 i .67 (SEE NOTE 12 -SHEET 1) ,pD g D -BOX -. .. W/INLET TEE I NV. EL: 96.75± NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INVERTS PRIOR TO CONSTRUCTION. 2) D -BOX SHALL BE SET LEVELDTRUEOGRADE ON A MECHANICALLY COMPACTEDS XINCH CRUSHED STONE BASE, AS SPECIFIED IN 310 CMR 15.221(2). 3) INSTALL INLET & OUTLET TEES AS NEEDED. 4) GAS BAFFLE TO BE INSTALLED ON OUTLET TEE AS MANUFACTURED BY TUF-TITE, ZABEL OR EQUAL. SEPTIC SYSTEM PROFILE N.T.S. EXISTING` / HOUSE (#39) ` Tor= 98.06/ As (sumed); � o O B II PROP, S.A.S. I L_ _ _ _ I 31.5' - S.A.S. LAYOUT i- F.G. EL: 94.0t INSTALL RISER OVER D -BOX TO WITHIN 6" OF FINISH GRADE L=23' 4" SCH 40 PVC 0 S= 1% (MIN. INV. ELEV.=91.50 NOTE: TO PREVENT BREAKOUT, A 40 MIL POLY F.G. EL: 94.5± LINER SHALL BE PLACED AS SHOWN ON THE PLAN AND SET BETWEEN EL. 92.0 AND EL. 89.0 2% MIN SLOPE OVER S.A.S. 4' SCH 4Q PVC PERFORATED PIPE WITH SCREW CAP SET TO WITHIN 3" OF FINISH 3-500 GALLON LEACHINGG•CHAMBERS GRADE TO SERVE AS INSPECTION PORT. IN SERIES WITH STONE ALL SIDES INSTALL RISER OVER CHAMBER SHOWN ON PLAN AND SET COVER WITHIN 6" OF FINISH GRADE 2" LAYER OF 1/8" TO 1/2" T®-2---a-mom DOUBLE WASHED STONE 2' EFF. DEPTH INV. ELEV.=91.00 TOP CONC. ELEV.=91.8 - INV. ELEV.=91.00 - BOTTOM ELEV.=89.00 - 5' MIN. ABOVE BOTTOM OF T.P. EXCAVATION OR G.W. NO G.W. ENCOUNTERED - BOTTOM OF TP EL: 84.0 SOIL LOG ILM DATE: JULY 13, 2006 SOIL EVALUATOR: PETER McENTEE CSE WITNESS: AMY VON HONE YARMOUTH HEALTH AGENT Elev. TP Depth 94.0 1 0" SANDY LOAM 10YR 4/1 93.5 B SANDY LOAM 10YR 5/8 92.0 C MED. SAND 2.5Y 6/4 84.0 6" 4V 5.2' 4' EFFECTIVE WIDTH = 13.2' 3' j 3 x 8.5' = 25.5' 3' EFFECTIVE LENGTH = 31.' LEACHING SYSTEM SECTION 3/4"-1 1/2" DOUBLE WASHED STONE -- BREAKOUT ELEV.=91.5 DESIGN CRITERIA NUMBER OF BEDROOMS: SOIL TYPE: DESIGN PERCOLATION RATE: DAILY FLOW: DESIGN FLOW: GARBAGE GRINDER: LEACHING AREA REQUIRED: EXISTING SEPTIC TANK o PETER T. Jr; McENTEE CIVIL Na. 35109 �pG 4 BEDROOMS CLASS 1 2 MIN./IN. 440 G.P.D. 440 G.P.D NO (440) = 594.6 S.F. .74 1000 GALLON CAPACITY (ESTIMATED) USE 3-500 GALLON LEACHING CHAMBERS IN SERIES SIDEWALL AREA: 2(13.2' + 315) X 2 = 178.8 S.F. 24" BOTTOM AREA: 13.2' x 31.5' = 415.8 S.F. TOTAL AREA: 594.6 S.F. DESIGN FLOW PROVIDED: 0.74(594.6) = 440.0 G.P.D. 120" PERC RATE: <2 MIN/IN ("C" HORIZON) NO GROUNDWATER ENCOUNTERED PROPOSED SEPTIC SYSTEM UPGRADE 39 MICHELLE'S PATH, YARMOUTH, MA Prepared for: David Barr, 39 Michelle's Path, Yarmouth, MA Engineering by: Surveying by: SCALE DRAWN JOB. NO. Engineeringworhs Terry A. Warner PLS NTS P.T.M. 187-06 12 West Crossfield Road 22 Long Road DATE CHECKED SHEET N0. Forestdale. MA 02644 Harwich, MA 02645 (508) 477-5313 (508) 432-8309 7/22/06 P.T.M. 2 Of 2