Loading...
HomeMy WebLinkAboutEngineered Plan - 20173I TOP FOUND. EL. 48.1' ------------------------- PRECAST H-10 RISERS (TYP.) 2'0 PROVIDE MIN. 20" DIAM. WATERTIGHT ACCESS COVERS TO WITHIN 6" OF FIN. GRADE MINIMUM .75' nF COVFP nVFP PPr ACT SYSTEM PROFILE (NOT TO SCALE) 2" PEASTONE OR GEOTEXTILE FILTER FABRIC OVER STONE ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. CONCRETE COVERS TO WITHIN 3" GRADE 2% SLOPE REQUIRED OVER SYSTEM 47.6 4" SCH40 VENT WITH CHARCOAL FILTER AS SHOWN PLAN VIEW PITCH BACK TO SAS, NO LOW POINTS. NOTE: 2" MIN. WALL THICKNESS REQUIRED BLOCKS OR 4"OSCH40 PVC MORTAR ALL PRECAST RISERS H-20 6" MIN. SUMP PIPES LEVEL 1ST 2' COMPONENTS 4' INV'S EL. 43.01 4' • 12" MIN. INT. DIM. ENDS (TMP) SIDES 44.00' "EXISTING ➢o;=oo�ooa . -. . • o 0 0 TEE 1000 GALLON �000 o�oo 000 o�ooM�� SEPTIC TANK TEE � ���� O 0��� oaa�� o --o�oo *43.4 0°°° N o0 0 o WATERTEST DBOX o°o°a°o°.��ooaooa�ao aooEl000a�aaooo°o°o°o°o° O'o°o°o°o° O O O O O 0 0 O O O O O O 7 O O O°o°o°° GAS BAFFLE ; ° ° ° ° ° FOR LEVELNESS n 'o°°°°°°° a000ao�o�ao ooanooaElm=°°°°°°° O O„O„°-� ) 0 0 0 0 0 0 0 FOUNDATION— EXISTING — SEPTIC TANK LEGEND- - 99— EXISTING CONTOUR X 99 EXIST. SPOT ELEV. PROPOSED CONTOUR [98.4] PROPOSED SPOT EL. TH1 _q� TEST HOLE COL) UTILITY POLE V FIRE HYDRANT 4Q� WATER SHUTOFF OCATCH BASIN WATER LINE W GAS LINE G OVERHEAD ELECTRIC OHE NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING TEST HOLE LOGS ENGINEER: CRAIG J. FERRARI, SE #138 WITNESS: BRUCE G. MURPHY, R.S, MP DATE: 10/25/17 PERC. RATE =_< 2 MIN/INCH CLASS I SOILS 4 ELEV. i p» 47.0' A LS 10" 1OYR 3/2 B LS 24" 1OYR 5/8 45.0' C PERC MS 1OYR 7/4 132" I 136.0' NO GROUNDWATER ENCOUNTERED LICE #17-373 °o°o°ao oMa��o�a�o� o�oc�0000�oo 00000 °° 43.27' 43.11' °°°°°° °°000 °°°o° 41.00 H-20 500 GAL. LEACHING CHAMBER BY ACME PRECAST OR EQUAL. 3/4"-1-1/2" DOUBLE WASHED STONE 4' MIN. (3) UNITS REQUIRED ALL AROUND PRECAST STRUCTURES 6" CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 33.50' X 12.83' COMPACTION. (15.221 [2]) o LO ( 1 % SLOPE) (-1-7. SLOPE) 13' D' BOX 12' LEACHING FACILITY 36.0 BOTTOM TH-1 NO GROUNDWATER FOUND *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM **INSTALLER SHALL CONFIRM MINIMUM SEPTIC TANK SIZE AT 1000 GALLONS AND ITS SUITABILITY- FOR UITABILITYFOR RE—USE, REPLACE WITH 1500 GALLON SEPTIC TANK APPROPRIATE TO SITE CONDITIONS IF NOT SUITABLE 0 10 20 30 40 50 FEET CHARCOAL FILTER GARAGE NOTES 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H—td- 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED BENEATH AND 5' AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH' CLEAN SAND. PORCH I LIVING ROOM KITCHEN DINING ROOM a m FIRST FLOOR PLAN NOT TO SCALE BEDROOM I' EDROOM w a 0 CO U FLOOR PLAN TO SCALE 7 rlcson ie orwo to5e T�� Kelley's Bay Locus m Foote Knob Hill glue Rock o Locus Old S NEricks s gi.VeT � ste�,� � Roin ° oorin9 .c 0 � a z LOCUS MAP SCALE 1"=2000'± ASSESSORS MAP 101 PARCEL 84 VARIANCE REQUESTED UNDER MAX. FEASIBLE COMPLIANCE BEDROOM 15.405 1b: SAS TO BE > 3' BUT < 6' BELOW FINISH GRADE (VENT AND H-20 PROVIDED) DEN SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED EXISTING 4 BEDROOM DWELLING BEDROOM ( DESIGN FLOW: 4 BEDROOMS 611-0 GPD = 440 GPD USE A 440 GPD DESIGN FLOW SEPTIC TANK: 440 GPD (2) = 880 USE A '1000 GAL. SEPTIC TANK'S-` LEACHING: SIDES: 2(33.5 + 12.83) 2 (.74) = 137 GPD BOTTOM 33.5 x 12.83 (.74) = 318 GPD TOTAL: 615 S. F. 455 GPD USE (3) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE ALL AROUND 'ermit valid for R PAIR tlf. st'll"FIC SVS'ru.rA PROVED DATE BOARD OF HEALTH INI.Y, due to State and. I oval septic variances. �oard.ofl;lcalth review and aphrnt,,! „required f�frTITLE 5 SITE PLAN ny fnttire to aildi.tions/reu�,rat�un.�nitcration�� ,wage facilities and/or structures/di+elling. OF Yarmouth 11c"i1fh 0epar'tment AP 'ROVEA)/r,&y�A 21 RUNE STONE ROAD SOUTH YARMOUTH, MA 4 - Date PREPARED FOR DATE DANIEL A. OJALA, P.E., P.L.S. , MA MARY E. HINES DATE: OCTOBER 27, 2017 off 508-362-4541 I fax 508-362-9880 downcope.com down ca►p� ���inc��ing, inc. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 17-373 CC SEPT] C_HINES. DWG , . & n Q Ll1 SEPTIC TANK: 440 GPD (2) = 880 USE A '1000 GAL. SEPTIC TANK'S-` LEACHING: SIDES: 2(33.5 + 12.83) 2 (.74) = 137 GPD BOTTOM 33.5 x 12.83 (.74) = 318 GPD TOTAL: 615 S. F. 455 GPD USE (3) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE ALL AROUND 'ermit valid for R PAIR tlf. st'll"FIC SVS'ru.rA PROVED DATE BOARD OF HEALTH INI.Y, due to State and. I oval septic variances. �oard.ofl;lcalth review and aphrnt,,! „required f�frTITLE 5 SITE PLAN ny fnttire to aildi.tions/reu�,rat�un.�nitcration�� ,wage facilities and/or structures/di+elling. OF Yarmouth 11c"i1fh 0epar'tment AP 'ROVEA)/r,&y�A 21 RUNE STONE ROAD SOUTH YARMOUTH, MA 4 - Date PREPARED FOR DATE DANIEL A. OJALA, P.E., P.L.S. , MA MARY E. HINES DATE: OCTOBER 27, 2017 off 508-362-4541 I fax 508-362-9880 downcope.com down ca►p� ���inc��ing, inc. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 17-373 CC SEPT] C_HINES. DWG , . &