Loading...
HomeMy WebLinkAboutEngineered Plan - 2017KEY: LOCUS EXISTING CONTOUR: - - - - PROPOSED CONTOUR: ------------- OL TOWN N EXISTING SPOT ELEVATION: 25.5 HOUSE RD/ S� PROPOSED SPOT ELEVATION: 25.5 9Tj 4 TEST HOLE: * S, Oti UTILITY POLE: FENCE LINE: HYDRANT 72_ RETAINING WALL: LOCATION MAP LOT 38 (17,950 SF) ASSESSORS MAP: 88 PARCEL: 23 PLAN BOOK: 179, PAGE: 89 I SEPTIC SYSTEM DESIGN FLOW ESTIMATE: 6 BEDROOMS AT 110 GAL / DAY = 660 GAL / DAY SEPTIC TANK: 660 GAL / DAY x 2 DAYS = 1320 GAL USE 1500 GALLON SEPTIC TANK (EXISTING) LEACHING AREA: USE 5 - 500 GALLON CHAMBERS (8.5'x 4.8'x 2' EFF. DEPTH) WITH _ 50.5' _ _ _ 4' OF STONE ALL AROUND (50.5'x 12.8'x 2' DEEP) SIDE AREA: (50.5' + 12.8') x 2 x 2 = 253 SF (0.74) = L87 GAUDAY N . bo BOTTOM AREA: 50.5' x 12.8' = 646 SF (0.74) = 478 GAUDAY ......' .............' CAPACITY= 665 GAUDAY LEACH AREA DETAIL OLD TOWN HOUSE ROAD j 100- - -- \ --.-- LCB\ Bikepath - _ 131.87' 1` N 89°53'30" E 20' DRAINAGE AND \ BIKE PATH EASEMENT c'c3` '------ X -----� ------ - i 100.7 -------- Stockade CLC 99 � "- Stockade Fence � 1 99 100 1 --- ------------------ --------------------/------------------- -------125-- Shed t , ................... BENCHMARK AT th-1 � Shed PAINT MARK ON / LP I CAPE & VINEYARD ELECTRIC CONCRETE PATIO COMPANY EASEMENT ELEVATION = 100.51 . 1 , 1 -- - -- -- - -- 12" tree Gardente ST � 90" tree 20 100.3 1 r 1 � 1 1 1 1 1500 gallon DECK r septic tank ---- O---------------------------------------------------------------� --------- -- o iv 1 rn o m - 0 ICD f sh CONCRETE PATIO ^ooi 0 GARAGE DECK invert = 98.4 invert = 98,7 2 I PAVED I DRIVE ► ► r 1100` \ r �\ r 1 I \ ROOM ABOVE EXISTING 6 BEDROOM DWELLING top fnd.= 101.99 PORCH \ i/ W / 101 -Q- S 89°53'30" W X100 SPARROW WAY E le M17-36 co r BATH �1 , 1 , , t 1 BED OFFICE rROOM SEPTIC SYSTEM SECTION COVERS WITHIN 6" TOPOPOF � ;, OF FINISHED GRAD 11 FOUNDATION 2" PEASTONE OR FILTER FABRIC - 3/4" -1 1/2" DOUBLE WASHED STONE INSPECTION PORT ELEV.= 97.65 4 & 98.7 O/A HORIZON ELEV. LOAMY SAND y T MAX. COVER 99.7 ELEV. d LOAMY SAND (1' MIN) 1 OYR 5/8 98 .0 C HORIZON a MEDIUM SAND 97.7 2.5Y 7/4 DGDr' , (EXISTING) ELEV. 97.46 H-20 g7,2g ° ° 97.95 ELEV. ELEV. ° ° ° ° 94.65 ELEV. D -BOX H H-20 H ELEV. 1500 (6" STONE UNDER) 4' 4' SEPTIC TANK 50.5'x 12.8' TEE SIZES: (TO BE CONFIRMED) 96.65 5 - 500 GALLON CHAMBERS WITH 4' OF STONE ALL AROUND INLET: 6" UP 13" DOWN OUTLET: 6" OR 14" DOWN ELEV. (50.5'x 12.8'x 2' DEEP) GAS BAFFLE AT OUTLET TEE , e4 OFMgS vFAr--�S c, C70 L TEST HOLE LOGS ENGINEER: THOMAS MCLELLAN, P.E. WITNESS: AMY VON HONE, R.S. DATE: 7-14-17 PERCOLATION RATE: < 2 MIN/IN NOTES: 1. VERTICAL DATUM: ASSUMED -- 2. MUNICAPAL WATER IS AVAILABLE. Yr d'E".3 oath Henit>h Department 3. SCHEDULE 40 - 4" PVC PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM. 2 j ' 4. ALL PRECAST UNITS SUBJECT TO TRAFFIC LOADS TO CONFORM WITH AASHTO H-20 SPECIFICATIONS. 5. PIPE PITCH = 1/4" PER FOOT (UNLESS NOTED OTHERWISE). �;'°"'' _m �10 : 6. FIRST 2' OF PIPE OUT OF D -BOX TO BE SET LEVEL, TH-1 100.5 O/A HORIZON ELEV. LOAMY SAND 101• 10YR 4/2 99.7 B HORIZON LOAMY SAND 30" 1 OYR 5/8 98 .0 C HORIZON MEDIUM SAND 2.5Y 7/4 DGDr' , 132"1 1 89.5 NO GROUND WATER ENCOUNTERED 7A4J_-27- S,46c: 2nd FLOOR KITCHENI LIVING ROOM DINING ROOM GARAGE PORCH EXISTING FLOOR PLAN BED BATH ROOM BED ROOM BED ROOM BED FAMILY ROOM ROOM BATH ROOM = ABOVE BERMROOM 1 st floor 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARBAGE DISPOSAL. 4 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE STATE OF MASS. ENVIRONMENTAL CODE (TITLE FIVE) AND LOCAL HEALTH REGULATIONS. 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. 10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT TO EXCEED 3' WITHOUT VARIANCE. 11. FIELD SURVEY PROVIDED BY TERRY A. WARNER, P.L.S., HARWICH, MA. 12. THIS PLAN REQUIRES THE REVIEW AND APPROVAL OF ONE OR MORE TOWN DEPARTMENTS AND IS SUBJECT TO CHANGE UNTIL SUCH TIME. 13. EXISTING LEACH PIT IS TO BE PUMPED, REMOVED AND REPLACED WITH CLEAN MEDIUM SAND. 14. D -BOX TO BE WATER TESTED TO ENSURE LEVELNESS AND EQUAL FLOW. 15. D -BOX AND LEACHING CHAMBERS ARE REQUIRED TO BE H-20 CLASS DUE TO BEING LOCATED WITHIN THE CAPE AND VINEYARD ELECTRIC COMPANY EASEMENT AUG 3 !` 2011 SITE PLAN THOMAS J. LOCATION: 60 SPARROW WAY, S. YARMOUTH, MA PREPARED FOR: PATRICK & DARLENE SHANNAHAN kTE: 7-14-17 SCALE: 1" = 20'J BASS RIVER ENGINEERING P E P.O. BOX 1163, EAST DENNIS, MA 02641 508-364-9048