HomeMy WebLinkAboutEngineered Plan - 20181.9' SYSTEM PROFILE (NOT TO SCALE) PROVIDE MIN. 20" DIAM. WATERTIGHT ACCESS COVERS TO WITHIN 6" OF FIN. GRADE 2" PEASTONE OR GEOTEXTILE FILTER FABRIC OVER STONE MINIMUM .75' OF COVER OVER PRECAST ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. CONCRETE COVERS TO WITHIN 3" GRADE 2% SLOPE REQUIRED OVER SYSTEM 131.3 NOTES 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. PRECAST H-10 NOTE: 2- MIN, WALL BLOCKS OR 4. DESIGN LOADING FOR ALL PROPOSED PRECAST THICKNESS REQUIRED UNITS TO BE AASHO H-10 RISERS (TYP.) PRECAST RISERS 20 30.8' 4"OSCH40 PVC MORTAR ALL H-10 6" MIN. SUMP PIPES LEVEL 1ST 2' ri COMPONENTS 5. PIPE JOINTS TO BE MADE WATERTIGHT. `' 12" MIN. INT. DIM. ENDS (TYP.) SIDES 29.33' .,... .. _ .e CONSTRUCTION DETAILS TO BE IN ACCORDANCE 10" **EXISITNG %TEE yo�o�o�ov' ° o o ° 6 CO STR TEE SEPTIC TANK*29.4' ° ° ° ° ®I�00 O CI�(]� En -L-0 --®pMr1 ;°o°°o°o°o° WITH ° ° ° ° ° ° WATERTEST D'BOX 'o°o0o°o° ����0M12EnE [� �0�®�OQ�MUD '°o°°o°°o°o° 310 CMR 15.000 (TITLE 5.) s o°o°o°o°o°o° 'o°o°o°o° O O O D O D O C7 O O CIO O O O O O O 'o°o°o°o° GAS BAFFLE ::; o^� 0 0 o FOR LEVELNESS (� j0000°0Oo OO�®O��aa�� ��O���O�Oa� ;o 0000000 ° ° ° 0000a�aoao�� C�000�0�®®�� •°°°°°°°° 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND 28.77' 28.60' ;°o°o°o°o :00000000 26.5 NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. LH -10' 500 CAL. LEACHING CHAMBER BY ACME PRECAST OR EQUAL. " 3/4"-1-1/2" DOUBLE WASHED STONE 4 MIN. (2) UNITS REQUIRED 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4 PVC. ALL AROUND PRECAST STRUCTURES 6" CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 25.00' X 12.83' 9. COMPONENTS NOT TO BE BACKFILLED OR COMPACTION. (15.221 [2]) o CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CALLINGTO GSAOFE SHALL1 8886 34A -71)77 7RESPONSIBLE LNDFOR LOCUS MAP FOUNDATION EXIST, LEGEND 99— EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. —[99]-- PROPOSED CONTOUR 198.41 PROPOSED SPOT EL. TH 1 TEST HOLE 2� SLOPE OF GROUND UTILITY POLE FIRE HYDRANT NOTE: NOT All SYMBOLS MAY APPEAR IN DRAWING (__4_% SLOPE) (1 % SLOPE) SEPTIC TANK 16' D' BOX 12' — *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM TEST HOLE LOGS ENGINEER: DANIEL E. GONSALVES, SE #13587 WITNESS: AMY VON HONE, RS DATE. 3/15/18 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS ELEV. I p" 4 31.5' A LS 10" 1OYR 3/2 B LS 22" 1 OYR 4/4 29.7' C PERC MS 1OYR 6/6 132" ' 120.5' NO GROUNDWATER ENCOUNTERED DCE #15-069 Pur ROOM BEDROOM PORCH LMNG ROOM BEDROOM BEDROOM DINING KlICHEN B•17t1 FAMILY ROOM DECK BATH EXISTING FLOOR PLAN BATF! I 20.5' BOTTOM TH-1 ( ) A NO GROUNDWATER FOUND VERIFYING THE LOCATION OF ALL UNDERGROUND & „ —, SCALE 1 2000 t LEACHING FACILITY **INSTALLER SHALL CONFIRM MINIMUM SEPTIC TANK SIZE AT 1000 GALLONS AND ITS SUITABILITY FOR RE—USE. REPLACE WITH 1500 GALLON SEPTIC TANK APPROPRIATE TO SITE CONDITIONS IF NOT SUITABLE 7o - Scale: 1 "= 20' 0 10 20 30 40 50 FEET a0� DATE OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL ASSESSORS MAP 68 PARCEL 122 BE REMOVED BENEATH AND 5'. AROUND THE LOCUS IS WITHIN FEMA FLOOD ZONE X PROPOSED LEACHING FACILITY. (AREA OF MINIMAL FLOOD HAZARD) AS 12. EXISTING LEACHING FACILITY SHALL BE PUMPED SHOWN ON COMMUNITY PANEL #25001CO587J AND REMOVED OR PUMPED AND FILLED WITH CLEAN DATED 7/16/2014 SAND. SITE IS WITHIN ZONE II DANIEL A. OJALA, P.E., P.L.S. SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 3 BEDROOMS @ 110 GPD = 330 GPD USE A 330 GPD DESIGN FLOW SEPTIC TANK: 330 GPD (2) = 660 **REUSE EXISTING 1000 GAL. SEPTIC TANK LEACHING: SIDES: 2 (25 + 12.83) 2 (.74) = 112 GPD BOTTOM 25 x 12.83 (.74) = 237 GPD TOTAL: 472 S.F. 349 GPD USE (2) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE ALL AROUND APPROVED DATE BOAR Yarmouth Health Department 1�4 rye Date , MA OF, HEALTH TITLE 5 SITE PLAN OF 1 ALMIRA ROAD SOUTH YARMOUTH, MA PREPARED FOR SONJA FELLMAN DATE: MARCH 20, 2018 off 508-362-4541 I fax 508-362-9880 downcape.com down cope engineering, int. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOU THPOR T MA 02675 15-069 FELLMAN.DWG