Loading...
HomeMy WebLinkAboutEngineered Plan - 2018TOP OF FOUNDATION ELEV. = 100.00_ (ASSUMED) 3.50 20 FT. MINIMUM FROM CELLAR OR CRAWL SPACE 10 FT. MINIMUM 10 FT. MINIMUM FROM SLAB CONCRETE COVERS 7 4" SCHEDULE 40 PVC PIPE MIN. PITCH 1/8" PER FT. 4" CAST IRON PIPE (OR EQUAL) MINIMUM PITCH 1/4" PER FT. TEE I j FLOW LINE N 10.1 t ELEV. = 8E.50 _ - MIN .'--- _ _�6.Ci0_ 2'0" ELEV. i LEVEL ELEV. = _96.2.5GAS ELEV. _ _ 95.0_0_ 6" SUMP ELEV. = _94.83_ BAFFLE �IS 1 171 B U T1 011" 4 ELEV. _ LIQUID OUTLET'��-;��3_� DEPT E (TO BE PLACED ON FIRM BASE) 4 FEET 14 INCHES TO BE WATER TESTED 5 FEET 19 INCHES r '"1 A,di IF MORE THAN ONE OUTLET 6 FEET 24 INCHES 1 95,00 �``�*�=M � `� 7 FEET 29 INCHES r z w =< �: a t� l= a (TO BE PLACED ON FIRM BASE) 8 FEET 34 INCHES 4 i 3/4" TO 1 1/2- CLEAN J DOUBLE WASHED STONE FREE OF FINES & SILT NOT TO SCALE EXISTING SPOT ELEVATION 0010 EXISTING CONTOUR----00---- COLOR FINAL SPOT ELEVATION Q�r. FINAL CONTOUR ()0 SOIL TEST LOCATION 10YR4/1 UTILITY POLE -O- ROOTS TOWN WATER =WSW 8 CATCH BASIN GAS LINE G '" 10YR6/8 CLEAN OUT C.O. ROOTS CESSPOOL C.P, 0 CLEAN SAND INSPECTION PORT LOAM AND SEED 2" LAYER OF 1/8" 70 1/2" WASHED STONE 98133 MAX. OR FILTER FABRIC VENT P5.08 AKIN. REQUIRED z G a et a: a 00 z—M. 1 010-1, 10 ° " o ° ° ELEV. _ _093.50_ 4 HIGH CAPACITY INFILTRATORS W1TH STONE IN AN 11' X 35' X 10" TRENCH'p FORMATION Z x.30 0 110 `n WELL N A _ ZONE y. ° INDEX !..f: ,. S ADJUST USGS PROBABLE WATER TABLE ELEV. = ------ OBSERVED WATER TABLE ( / / ) ELEV. = BOTTOM OF TEST HDLE ELEV. = 3I T.�' DATE OF SOIL TEST APRIL 3L 2018 SOIL TEST DONE BY R._WILCOX WITNESSED BY 0r ' 99,2 t,a ":." , � � `� x r L,.E i ELEV.=------ PERCOLATION RATE _ <_Z__ MIN,/INCH AT 43___ INCHES DEPTH HORIZ TEXTURE COLOR MOTT. OTHER 0-4" Ap LOAMY SAND 10YR4/1 INO ROOTS 4-23" 8 LOAMY SAND 10YR6/8 ,= SOIL CLASSIFICATION �� ROOTS 23-132" C MEDIUM SAND 2.5Y7/4 1 III NO WATER ENCOUNTERED AT _132'- ELEV. _ _ 88.2 i E£ 1 C ALC U IA 0N ,- ! NUMBER OF BEDROOMS 2 D`-aG"ED AS 3 GARBAGE DISPOSAL UNIT TOTAL ESTIMATED FLOW 1 ( 110 GAL/EP./DAY X BR.) _ 2n-_ GAL./DAY _a REQUIRED SEPTIC TANK CAPACITY Q_ GAL, ACTUAL SIZE OF SEPTIC TANK _�v�00 GAL. . ,= SOIL CLASSIFICATION �� DESIGN PERCOLATION RATE <-5 _ MIN./IN. ~' EFFLUENT LOADING RATE --QJ GAL./DAY/S.F. a- LEACHING AREA 7-4-,M SQ. FT. (11X38)+(47X2X10/12) LEACHING CAPACITY (AREA X RATE) 351 009 GAL./DAY - 474.33 X 0.74 RESERVE LEACHING CAPACITY. -MQ-N-F, GAL./DAY {� 1. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO D.E.P. t .. TITLE 5 AND THE TOW'N'S RULES AND REGULATIONS FOR THE SUBSURFACE DISPOSAL OF SEWAGE.. 2. ALL COVERS TO SANITARY UNITS SHALL BE BROUGHT TO WITHIN 6" OF FINISHED GRADE. 3. ALL COMPONENTS OF -THE SANITARY SYSTEM SHALL BE CAPABLE OF WITHSTANDING H-10 LOADING UNLESS THEY ARE UNDER OR WITHIN 10 FT, OF DRIVES OR PARKING AREAS. H-20 LOADING SHALL BE USED UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS. 4. ANY MASONARY UNITS USED TO .BRING COVERS TO GRADE SHALL BE MORTARED IN PLACE, 5. NO DETERMINATION HAS BEEN MADE .AS TO COMPLIANCE WITH DEEDED OR ZONING REGULATIONS. OWNER / A.PPLICANT. IS TO OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY. 6. UTILITIES SHOWN ARE :APPROXIMATE ONLY, EXCAVATION .CONTRACTOR IS TO CALL "DIG -SAFE" AT -1-888-344-7233 :AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE.. 7. CONTRACTOR IS TO VERIFY GRADES AND ELEVATIONS AS WELL AS SITE CONDITIONS PRIOR TO COMMENCING WORK ON SITE. ANY VARIATION IS TO BE BROUGHT TO THE ATTENTION OF THE DESIGN ENGINEER IMMEDIATELY. 8....Pt>EpCE� ...lS_sN aal_000 ZOR1= - 9. LOT IS SHOWN ON ASSESSORS MAP _8 AS PARCEL _ 172__, 10. EXISTING CESSPOOL IS TO BE PUMPED AND BACKFILLED.: 11. VARIANCES TO TITLE 5 AND 'YARMOUTH REGULATIONS: A. SOIL ABSORPTION SYSTEM LESS THAN 20' FROM FOUNDATION (VAR. OF 2.3'). B. SOIL ABSORPTION SYSTEM LESS THAN 10' FROM STREET, (VAR. OF 2.3'). C. SOIL ABSORPTION 'SYSTEM MORE THAN 3' ON GROUND .(VAR.::OF 1.6'). - D. NO RESERVE AREA. Permrt :valid for REPAIR OF SEPTIC ,SYSTI R1 ONI Y, due to State and Coeal septic viariances. Board of'1lealth;revriw:and appngxaI is required fo . any fufirre additiu.ns/rcn%iwi.tionc/alteratirtns to sewage fiterlitie,s and/or structures/dwelling: , t Yarmouth HFalth'.1?cp irt�irrnt APPROVED/,feXl�f Date athe -OE':Fl EA L t DATE AGENT FOR 01.`l�$ t Dip - L aa� d :.��.x - a ..� .�. DATE IP I.:: 6, : 218 SCALE � mA. Ir.;. m.-m..�±;. . s-esa�iax„•m.:u»� x�e„ss....c...rx�esm � REV. JCB NOft r REV. - LOCATION MAP . SHEET . 1 _ 0l :. C. �S8 P,DD✓. 8 06-0091 dtv” $'O0&-SsIS.DiYG . "2018 T..M. NAYES, R.S: