HomeMy WebLinkAboutEngineered Plan - 2018SYSTEM PROFILE PROVIDE MIN. 20" DIAM. WATERTIGHT (NOT TO SCALE) ACCESS COVERS TO WITHIN 6" OF FIN. GRADE 2" PEASTONE OR GEOTEXTILE FILTER FABRIC OVER STONE ZO.B' MINIMUM .75' OF COVER OVER PRECAST PRECAST H-10 RISERS (TYP.) 2'0 : U 10" "EXISTING 14" TEE SEPTIC TANK TEE (STING GAS BAF +: 4' LIQ. LEVEL (ACME OR EQU *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM **INSTALLER SHALL CONFIRM MINIMUM SEPTIC TANK SIZE AT 1000 GALLONS AND ITS SUITABILITY FOR RE—USE. REPLACE WITH 1500 GALLON SEPTIC TANK APPROPRIATE TO SITE CONDITIONS IF NOT SUITABLE FOUNDATION EXISTING — SEPTIC TANK LEGEND- - 99— EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. —[99]-- PROPOSED CONTOUR 198.41 PROPOSED SPOT EL. TH 1 454 S.F. 12" TEST HOLE 2� SLOPE OF GROUND (ACME OR EQUAL) UTILITY POLE LS FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING TEST HOLE LOGS ENGINEER: CRAIG J. FERRARI, SE #13871 WITNESS: AMY VONE HONE, RS DATE: 3/28/18 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS 4 ELEV. 0„ 20.2' A THIS PLAN IS FOR PROPOSED WORK ONLY AND LS 16.3 1OYR 2/2 454 S.F. 12" 19.2' ,0,0000 14.2 B (ACME OR EQUAL) WITH 2.5' STONE AT SIDES, 4' AT LS LH 30" 1 OYR 5/6 17.7' ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. CONCRETE COVERS TO WITHIN 3" GRADE - - - - --- --- - -- - ---f NOTE: 2" MIN. WALL THICKNESS REQUIRED MORTAR ALL BLOCKS OR COMPONENTS PRECAST RISERS 4"�SCH40 PVC H-10 6" MIN. SUMP PIPES LEVEL 1ST 2' 4' 5' INV'S EL. 16.2' 72" MIN. INT. DIM. ENDS gET, (NP') D0000ep�eori no . O O O O ° o *17.5±'0.'0.' ° o 0000 :o... ooc� °oho ooPAo-o noxa °°°° ®®�®oM000a� oa�a000aaa® NOTES 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H -1Q —2 5. PIPE JOINTS TO BE MADE WATERTIGHT. SIDES 17.03' 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH ITH 0° 310 CMR 15.000 (TITLE 5.) LE °o°00000°000 WATERTEST D BOX p ,O°°°°°°° oO°O°OOO°OOO FOR LEVELNESS Ci '0°0°0°0° , 0 00 0 1000°,°,° 00°000. ®�®®®®®�®®® oo°o°O0 00 �aaaooa�MoFP o,°,°, ®®®®0��®0®�01_00000_ ooaaa000000°0°,°0°,16.46 00 $-0.-.00.0000'11 ° ° ° °7. THIS PLAN IS FOR PROPOSED WORK ONLY AND L) 16.3 0000°°°° ° ° ° ° 454 S.F. 000°0 000°°° GPD ,0,0000 14.2 NOT TO BE USED FOR LOT LINE STAKING OR ANY (ACME OR EQUAL) WITH 2.5' STONE AT SIDES, 4' AT ENDS LH BETWEEN UNITS OTHER PURPOSE. -10 500 GAL. LEACHING CHAMBER BY ACME PRECAST OR EQUAL. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 3/4"-1-1/2" DOUBLE WASHED STONE (2) UNITS REQUIRED 6" CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 30' X 9.83' 9. COMPONENTS NOT TO BE BACKFILLED OR COMPACTION. (15.221 [2]) (_L-5_% SLOPE) — 23' — (—L% % SLOPE) — 12' — LEACHING FACILITY VARIANCES REQUESTED: UNDER MAX. FEASIBLE COMPLIANCE 15.405: (1b): REDUCTION IN SETBACK, SAS TO FOUNDATION (20' TO 19.9') CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND 8.2' BOTTOM TH-1 VERIFYING THE LOCATION OF ALL UNDERGROUND & NO GROUNDWATER FOUND OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF C C PERC 19 �p MS ;I 1OYR 7/4 144" I 18.2' NO GROUNDWATER ENCOUNTERED DCE #18-073 Scale: I"== 20' 0 10 20 30 40 50 FEET WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED BENEATH AND 5' AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. BEDROOM BATH DINING BED KITCHEN ROOM BEDROOM LIVING ROOM FLOOR PLAN —NOT TO SCALE— Yarmouth Health Department P Naane Date LOCUS MAP SCALE 1 "=2000'± ASSESSORS MAP 49 PARCEL 211 LOCUS IS WITHIN FEMA FLOOD ZONE X (AREA OF MINIMAL FLOOD HAZARD) AS SHOWN ON COMMUNITY PANEL #25001 CO587J DATED 7/16/2014 SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 3 BEDROOMS @ 110 GPD = 330 GPD USE. A 330 GPD DESIGN FLOW -� SEPTIC TANK: 330 GPD (2) = 660 **RE—USE EXISTING 1000 GAL. SEPTIC TANK LEACHING: SIDES: 2 (30 + 9.83) 2 (.74) = 118 GPD BOTTOM 30 x 9.83 (.74) = 218 GPD TOTAL: 454 S.F. 336 GPD USE (2) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 2.5' STONE AT SIDES, 4' AT ENDS AND 5' BETWEEN UNITS MA APPROVED DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF 7 MERGANSER LANE WEST YARMOUTH, MA PREPARED FOR BORTOLOTTI CONSTRUCTION/ TIMOTHY M. & JESSICA L. BADACH L1_%i-t1z DATE DANIEL A. OJALA, P.E., P.L.S. DATE: APRIL 4, 2018 >, off 508-362-4541 I fax 508-362-9880 downcape.com down cave eninforiag, inc. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 18-073 BORTO—BADACH.DWG