Loading...
HomeMy WebLinkAboutEngineered Plan - Rev. 2018ALARM AND DUPLEX CONTROL PANEL TO BE INSTALLED INSIDE w �r BUILDING. ALARM TO BE ON 71 SEPARATE CIRCUIT FROM PUMP PROP. WATERTIGHT COVER TO GRADE PROVIDE QUICK DISCONNECT FOR PUMP 37.5' INV. IN 34.53' 1 NO LOW POINTS 500 GAL. H?,p S/T 2" PRESSURE LINE -E- ALARM ON '754 GAL.+ SLOPE TO DRAIN BACK TO PC FLOAT SWITCH RESERVE 0.25" WEEP HOLES I SETTINGS: PUMP ON 8., CHECK VALVE 4" WORKING RANGE DUPLEX MYERS SRM 4 4" SUBMERSIBLE 4/10 HP PUMPS PUMP OFF 8" SYSTEM (OR EQUAL) 00o c0000 0 000000 0000 0 0 0000 PUMP CHAMBER TEST HOLE LOGS ENGINEER: DANIEL A, OJALA, PE. SE#1805 WITNESS: AMY VON HONE R.S. DATE: 9/7/05 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS 0" 2" 600 32" PERC E 84" ELEV. 35.5' 0" 35.3' 2" 4 (NOT TO SCALE) WATERPROOF/WATERTIGHT TEST HOLE LOG SLAB EL. 38.0' 0' 34.8' u *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM 2 ( q SLOP FOUNDATION- 10' ENGINEER: DANIEL A, OJALA, PE. SE#1805 WITNESS: AMY VON HONE R.S. DATE: 4/10/01 PERC. RATE _ < 2 MIN/INCHVj CLASS I SOILS ELEV. 35.0' 0) • 41 0 0 ORGANIC ORGANIC 0 10YR 3/2 10YR 3/2 34.8' 2" A A q SL SL LS 10YR 3/2 35.0' 6» 10YR 3/2 10YR 5/2 B B 4" LS LS B 2.5Y 6/4 32.8' 32" 2.5Y 6/4 32.3' LS C1 C, 48 2.5Y 7/6 M/FS M/FS 2.5Y 7/6 28.5' 84" 2.5Y 7/6 PERC C C2 C2 M/CS M/CS M/CS 2.5Y 6/4 7 2.5Y 7/6 144" 2.5Y /6 23.5' 150" 22.5' 146" 24.8' GROUNDWATER ENCOUNTERED GROUNDWATER ENCOUNTERED GROUNDWATER ENCOUNTERED 9 EL. 24.6 @ EL. 24.7 34.5' ELEV. 37.0' 28.0' 36.7' 33.0' 31 C� EL. 26.17 6" FRAME H-20 F&C 36.3f VARIES ; TOP OF STRUCTURE EL. 35.61 TOP OF STRUCTURE EL. 35.5f 4"LOAM & SEED g" HIGH FRAME H-20 F&G ALL DISTURBED AREAS (TYP.) RIM ELEVATION 36.3f VARIES PAVEMENT SLOPE 1.3% MIN. TO BASINS ELEV. VARIES 36.5 - 37.5 OVER TRENCHES CAPE COD BERM 12" X 3" AS SHOWN MORTAR ALL COMPONENTS PAVEMENT SLOPE 1.3% MIN. TO BASINS ELEV. VARIES 37.0-38.0 OVER TRENCHES (TYP.) I' TOP PIPE .RIBS EL. 34.4± (SET LEVEL) 1.1'-2.0' • . - '...... •. .: :.. •.. ...: .: .........• .•.-• ::.. •.:•. 4a'''• e•4: •J:; •• '•> : SEE• PAVEMENT SECTION I I I I( I I I I I I I I I(( I I I I I I 33.4 N 33.5 33.6 SLOPE 0.5% MIN. (TRENCHES LEVEL) � • v, A � A CL a �- •< NOTE: ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL PIPE INVERT EL. LEVEL AT 33.4 / e :2 o •.. � t PERF. ADS -N-12- PLUS CUT w BE REMOVED 2' BENEATH AND AROUND PERIMETER OF D , SLOTS WITH SKILLSAW E.O. RIB DRAINAGE, DOWN TO SUITABLE SOIL LAYER. REPLACE WITH BOTTOM TRENCH LEVEL AT 32.4 "� A. � C.B. TRAP � DRILL (2) 1 OR PURCHASE SLOTTED PIPE � CLEAN MED. SAND 1 1/2" WASHED STONE (TYP.) 12"0 CPP � a HOLES (TYP.) 2 MIRAFI 140N TOP °p ASND SIDES LT SECTION A -A COMPACT ALL BACKFILL NOTE: SLOT PERFORATED ADS N-12 PIPE WITH SAWBLADE ELBOW IN 6 LIFTS (95% PRCTR.) 124H-20 HDPE PIPE .� 2'°. 1' _ •�2'.•� 1 /4" WIDE EVERY THIRD RIB, ALTERNATING SIDES ENTIRE LENGTH TYP.°n oo°°on°o`o•.'; -; . , .�", 2.0' ' •• o 0 00 00 0 0 00 00 o INV. LISTED LEACHING TRENCH TO BE `.. 28.83 6b - A; =;;: =-.:_'•c, "�.. "-. • • ,, � a o 000000 00 000 0 0000 SET IN CLEAN SAND ONLY, ' ' • . �• • . a• '• a a • • a •a -. a• .a .r 28.93 Z A J� ' , 5 • ' REMOVE UNSUITABLE FOR 5 AROUND I 4 4' I.D. H-20 DEEP SUMP OVERALL HEIGHT 6'-8"t :2 / DOWN TO SUITABLE MATERIAL 0 3/4" - 1 1/2" AND REPLACE WITH CLEAN COARSE SAND � CATCH BASINS (TYP.) N � WASHED STONE UNDERNEATH ACME, SHOREY, OR EQUAL AND BESIDE PIPE 4' I.D. H-20 DEEP SUMP OVERALL HEIGHT 6'-8"f aDJ G.W. WIDTH AND LENGTHS LISTED ECCENTRIC FLAT TOP STRUCTURE MANHOLE 48" DIA STORM DRAIN ACME, SHOREY, OR EQUAL SECTION THRU DRAINAGE DRAINAGE CROSS SECTION ECCENTRIC FLAT TOP STRUCTURE I SYSTEM PROFILE MARK CORNERS 0� NOTES xit 7 LEACHING FIELD W (NOT TO SCALE) REBAR SET 4" BELOW VENT W/ CHARCOAL FILTER / GRADE INSPECTION PORT �i • z. a 1. DATUM IS NAVD 88 __I q�l OVER PRFrART X 4. DESIGN LOADING j z Route 6 Yarmouth °j ACCESS COVERS TO WITHIN 6" OF FIN. GRADE 2% SLOPE � 2. MUNICIPAL WATER IS AVAILABLE ComP9 round FILTER FABRIC � SEE PAVEMENT SECTION ID 7.8 TOP 36.77' FINISHED GRADE- 4" LOAM &SEED OR PAVE AS REQ. 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 37.8' MI IMUM J5' OF COVER R ALL PROPOSED PRECAST ITS «<JJJ CLEAN FILL TO BE AASHO H-ZQ _ - PRECAST H-20 :::., •.;;.;... .: ••.::.•;-,::.. .• .: . - ... :�,.,••,. 4"0SCH40 PVC .........;:. ..:...:............:....:......::..,.,•;.;.:...:.. •. RISERS (TYP.) � CONNECT AND VENT 2'0 Q4. : PIPES LEVEL 1ST 2' a^ PERFORATED PVC 5' D.C. 5=0.005 -- .o. � 5. PIPE JOINTS TO BE MADE WATERTIGHT. / a � • 10" - m 3/4"-1-1/2" DOUBLE WASHED o 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH � •�' TEE '•'� :.' �� � E • 12" STONE LEACHING FIELD 0 6"DEPTH ,MIN BELOW INV. 310 CMR 15.000 (TITLE V.) Barnstable Locus 24" 34.55' WATERTEST D'BOX 36.4' Munic/ °l yi99m � 24" TEE Q ° LEVEL BOTTOM o TEE°°°°°°�°°°° FOR LEVELNESS 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO Airport COMM Rood °�e�� GAS BAFFLE GAS BAFFLE C 36.62' 36.45' BE USED FOR LOT LINE STAKING OR ANY OTHER Electric � 51.0' PURPOSE. 1538 GAL COMP. �799 GAL COMP. 4 • s.zs• 3.25' Q 35.4' 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. cocheset VOOvOavO O�O"O�O"0�0�0` O. O°Oovo"o•°o"o"o"o o• o`';,L �i 5.0' 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED � •o°o°o°o°o°o°o°o°o°o°o°o°ooo°oo°o°o°o°o°o°o WITHOUT INSPECTION BY BOARD OF HEALTH AND 000000000�o,�o�o�0000000000opo0o0ono,�0000000. � PERMISSION OBTAINED FROM BOARD OF HEALTH. 6" CRUSHED STONE OR MECHANICAL GROUNWATER ENCOUNTERED 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING COMPACTIo�® EL. 24.7 1N TH2 J. (15.221 [2]) USE ADJUSTED DIGSAFE (1-888-344-7233) AND VERIFYING THE GROUNDWATER ®EL. LOCATION OF ALL UNDERGROUND &OVERHEAD UTILITIES LOCUS MAP 30.4 PER PREVIOUS TEST PRIOR TO COMMENCEMENT OF WORK. E) (-L7. SLOPE) � (-l-% SLOPE) HOLES IN AREA 2500 GAL H-20 I; ��• LO 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE NOT TO SCALE SEPTIC TANK 2' PUMP 1 36' D' BOX 7' LEACHING REMOVED 5' BENEATH AND AROUND THE PROPOSED CHAMBER I' FACILITY LEACHING FACILITY. ASSESSORS MAP 73 PARCEL 9-2-6 LEGEN D I ZONING SUMMARY JT�LITE %OS" AND I C`32 R A D I 114"G r"I"ITE PLAN OF LAND 0 EXISTING CONTOUR 9.1 EXIST. SPOT ELEV. 99 PROPOSED CONTOUR 198.41 TH1 PROPOSED SPOT EL. MIN. LOT SIZE TEST HOLE MIN. LOT FRONTAGE .SLOPE OF GROUND 71) UTILITY POLE 30' FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING Scale: 1 /4"= 1'-0" @ DCE #05-207 s NOT TO SCALE DATE DANIEL A. OJALA, P.E. P.L.S. ZONING DISTRICT: 63 BUSINESS DISTRICT EXISTING PROPOSED MIN. LOT SIZE 40,000 S.F. 40,104- S.F. MIN. LOT FRONTAGE 100' 396.7' MIN. FRONT SETBACK 30' 30.5' MIN. SIDE SETBACK 10' 10.5' MIN. REAR SETBACK 30' N/A MAX. BUILDING COVERAGE 35% 17.6% PROPOSED IMPERVIOUS COVERAGE = 59.7% SITE IS LOCATED WITHIN ZONE 2 EXISTING USE: VACANT LOT PROPOSED USE: OFFICE BUILDING OWNER OF RECORD LOUIS J. SEMINARA TRUST P.O. BOX 1219 SOUTH DENNIS, MA 02660 REFERENCES DOC# 1008278 LC PLAN 37201D SYSTEM DESIGN: 5,860 S.F. OFFICE @ 75 GPD/1000 S.F. = 440 GPD 1,639 S.F. STORAGE 0 GPD/1000 S.F. = 0 GPD - TOTAL DESIGN FLOW ESTIMATE= 440 `GPD r SEPTIC TANK: 440 GPD (2) = 880 (FIRST COMPARTMENT) 440 GPD (1) = 440 (SECOND COMPARTMENT) 880 + 440 = 1320 GAL. REQUIRED USE A 2500 GAL. DUAL COMPARTMENT SEPTIC TANK LEACHING: 440 GPD (.74) = 595 SF REQUIRED 20' X 51' = 1020 SF OK 1020 SFX .74 = 755 GPD OK USE A 20' X 51' PIPE AND STONE LEACHING FIELD NITROGEN CALCS: 110 GPD/10,000 SF ALLOWED 40,007 SF x 110 GPD/10,000 SF = 440 GPD PREPARED FOR DATE: AUGUST 24, 2015 REV.: SEPTEMBER 4, 2015 REV.: SEPTEMBER 21, 2015 � REV.: MARCH 30, 2018 (LARGER SEPTIC) i �e` 0 10 20 30 40 50 FEET off 508-362-4541 �y�• fax 508-362-9880 downcape.com Q � 00W4 We MPrifteeri7j, h7c. civil engineers land surveyors 1 � 939 Main Street (Rte 6A) YARMOUTHPORT MA 02675