Loading...
HomeMy WebLinkAboutEngineered Plan - 2018TREE REMOVAL KEY 1. DBL. EASTERNREE CEDAR 7" - WIND FELLED, OCT. 31, 2012 DBL. BLACK CHERRY, 10" & 12" 3. BLAC"AK 4. 9" .R. EDAR 5. 6" E.R. DAR 6. 4" 6RN �iTAL(CRAB APPLE) 7. 1" E.R. CEDAR ,v 15" E.R. CEDAR 9, DBL BLACK OAK 5'k& 6" �P _� / 1 � y .• SEPTIC SYSTEM VARIANCE HISTORY • EXISTING SAS IS 78 FT. FROM SALT MARSH W/ VARIANCE OF 22 FT. FROM THE SALT MARSH; PROPOSED REPLACEMENT SAS IS 91 FT. FROM MARSH • EXISTING SAS IS 139 FT. FROM AN EXISTING WELL; PROPOSED SAS IS 140 FT. FROM THE SAME WELL. 1 • PROTECT ALL / EXISTING TREES GENERAL NOTES 1. ELEVATIONS REFER TO NGVD 1929. ELEVATION BENCHMARK IS THE TOP OF THE EXISTING CAST IRON TANK COVER IN THE DRIVEWAY. FOR NAVD88 CONVERSION SUBTRACT 1.1 FROM ANY GIVEN ELEVATION. CONTACT CAPE COD ENGINEERING, INC. FOR ADDITIONAL ELEVATION INFORMATION. 2. PLAN REFERENCE: TOPOGRAPHIC SURVEY PREPARED BY DOWN CAPE ENGINEERING, INC. 3. ALL SEPTIC SYSTEM CONSTRUCTION MATERIALS AND PROCEDURES SHALL CONFORM TO THE STATE SANITARY CODE, TITLE 5 AND TOWN OF YARMOUTH HEALTH DEPT. RULES AND ,APPROVAL FOR THE DESIGN. 4. INTERIOR PLUMBING CHGANGE IS REQUIRED TO RE-ROUTE THE SOIL PIPE TO EXIST THE FOUNDATION WHERE SHOWN. 5. INSTALLATION CONTRACTOR SHALL VERIFY THE PVC PIPE CONDITION AT THE FOUNDATION CONNECTION PRIOR TO SETTING COMPONENTS AND MAKING THE NEW CONNECTIONS. CONTACT CAPE COD ENGINEERING, INC. PRIOR TO MAKING ANY CHANGES. FROM THE PLAN. 6. A 5 FT. PERIMETER EXCAVATION AROUND AND BELOW THE SAS TO AN APPRXIMATE DEPTH OF 8 FT. IS OPTIONAL BUT RECOMMENDED SUBJECT TO INSPECTION PRIOR TO RE -FILLING WITH CLEAN SAND. C1 LAYER PERC TESTED; C2 IS SLIGHTLY CLEANER; C3 IS CLEAN .7. ALL EXCAVATED SOIL SHALL BE TRUCKED OFF SITE AND SELECT MATERIALS TRUCKED IN TO RE -FILL THE EXCAVATION AND TO PROVIDE SUITABLE SUBSOILS AND TOP SOIL ABOVE THE SAS. 8. CONTACT CAPE COD ENGINEERING, INC. PRIOR TO EXCAVATION TO REVIEW SPECIFIC REQUIREMENTS FOR THE EXCAVATION AND RELATED SITE WORK. ' • ``y 9. EXISTING SAS COMPONENTS SHALL BE LOCATED AND REMOVED FROM THE SITE OR SAND FILLED WHERE NOT IN . CONFLICT WITH THE NEW SAS. BACKFILL AND COMPACT EXCAVATION AREAS WITH APPROPRIATE CLEAN SAND. PROTECT ORi it 12x6 ? 10. SEPTIC SYSTEM INSTALLER SHALL CONTACT ENGINEER AT TIME OF SYSTEM COMPLETION FOR SYSTEM CERTIFICATION / kkOVE L.P. ` a , . ` 43 • 86 AS REQUIRED. k, GAS TANK i r� 11. CONTACT ENGINEER IF ANY QUESTIONS OR DOUBTS ARISE REGARDING SOIL CONDITIONS ENCOUNTERED DURING 016.5 F CONSTRUCTION. / / / / / \ / • f i T 1 / �O,y 12. NO KNOWN POTOBALE WELLS EXIST WITHIN 200 FT. OF THE PROPOSED SEPTIC SYSTEM OTHER THAN THOSE ' INDICATED. REMOVE & ; 13. CONSULT WITH PROPERTY REPRESENTATIVE FOR APPROPRIATE LANDSCAPE SOIL COVER REPLACEMENT OVER THE • • i ! I o• UT1L POLE SAS AND SURROUNDING AREAS. REPLACE ALE 12 12x6 - VER;FY & CLEARDESIGN DATA SERVICE PIPES `� / o ALL U.G. UTILITY • CONDUITS HYDRAULIC LOADING - 6 BEDROOMS X 110 GPD/BR = 660.0 20'GPD PROPOSED o SEPTIC T NK DESIGN 4"0 PIPE GE 200 X 660 GAL. 1,320 GAL. P OVIDE A 2,500 GAL. PRECAST . r O 2x4 EXISTING G, 5• Eta ;• �� 0 ; CONCRETE SEPTIC TANK RATED FOR H-20 LOADING SAS DESIGN 1 1 / /ABANDON, I �--� �" Q Q�,BENC R P� I ,6 pP� / BENCHMARK: PERCOLATION RATE OF THE C1 LAYER - 5 MPI (CLASS 1) PUMP OUT & l �1rf',- �; Q tC.I. COVE o / TOP OF CONC. BOUND LONG TERM HYDRAULIC LOAD RATE = 0.74 GAL/S. F. / SAND FILL �� ¢ o N �� \� L ---- -1 EL. = 13.53 . pP� / I ELEV. = 14.9 , Q ELE o SIDE AREA = 2(2)(41 + 16.5) = 230.0 S.F. / EXIST. S. TAN �� �- � a � � � G• ���ES 1 _ _ (APPROX. LOG.) /� �" w RUN-OFF z oP� z pP� BOTTOM AREA - 16.5' X 41' - 676.5 S.F. • • �/ // // �, iw CISTERN �k'j 9 0•�1 ' 1 LOADING: (906.5 S.F. X 0.74 GAL/S.F./DAY) = 670.8 GPD TOTAL LEACHING CAPACITY - 670.8 GPD ZONE. -12 EC. -12 �/ l ; �, g Z oP�. pP� o *THE DESIGN IS NOT SUITABLE FOR USE WITH A GARBAGE DISPOSAL Al2 �� l l r �w �2 Q UNIT _ -- - - I - - - -- ---- _ -- _ _` _ - - - .__ SA�ONSTRUIT(OtT- N • O a, PROPOSED . SAS CONSISTS OF SEVEN (7) PRE -CAST CONCRETE, 500 GALLON DRYWELL UNITS AS o Q MANUFACTURED BY SHOREY PRECAST, INC. OR EQUAL, H-20 RATED, PLACED SIDE -TO-SIDE IN A �Ss� pP� o 16.5 FT. W. X 41 FT. L. EXCAVATION, > "'"' G SET TO THE INDICATED ELEVATIONS SURROUNDED BY 1 IN. v' o oP �`' j j U DIAMETER, DOUBLE -WASHED STONE; A 2 IN. THICKNESS LAYER OF % TO 3/8 PEASTONE SHALL BE / o FLOOD ZONE 9. -� SET IN PLACE ABOVE THE INLET PIPE OR USE A SUITABLE GEOTEXTILE FILTER CLOTH; THE THREE I lox" INLET UNITS SHALL HAVE RISERS WITH COVERS TO WITHIN 6 INCHES OF FINISHED ,GRADE. I I F • •„ OPS eP 1 I I X • �2 pPFzC DEEP OBSERVATION HOLE #I . w G� \ I j ,` • Test Date: December 13, 2017; \ I Witness: Amy VonHone, RS, YARMOUTH HEALTH DEPT. \ \ I a PERFORMED BY R. Perry TOP OF FOUNDATION EL = 13.75 FINISH GRADE = 13.0f 80' 6. OF 3/4' TO 1-1/2" DIA. STONE ',L12 BELOW TANK NOTE: ALL PIPE TO BE 4" DIA. PVC TIGHT JOINT WITH MINIMUM SLOPE OF 1/8" PER FT. - elevation depth (in.) I texture color mottling other 12.5-11.5 I I A. • IOYR 3/3 \ 12-42 B loam. sand ' 9.0-6.5 42-72 C 1 loam. sand 10 YR 6/8 I 6.5-4.2 21 C2 loam. sand 10 YR 5/4 A,? -- -12- - - - --- - 4.2-1.5 \ �I �>>, �---- ! • __ •- � PLAN -^ I �'"', 20 10 0 20 60 i s 1 inch = 20 ft. 18' DIA. MANHOLE WITH CONCRETE COVER PROVIDE RISER WITH COVER TO WITHIN 12' OF GRADE AND FRAME BROUGHT TO WITHIN 6" 2' LAYER OF 1/8' - 3/8' DIA. OF FINISHED GRADE WASHED STONE OR FABRIC FINISH GRADE = 12.6t r a t It v ::. Q Z :. ti -.. a o^ Z MINIMUM D -BOX INV, -9 F cfl o N CLEAN BAKFILL:':. :: �) ;.... a ov N INSIDE DIMENSIONS 12"x12' 1 H-20 6 H-20 7 y a0o071000 00 r713Moo®o0o00 rp/ o :' 00000000 CO000O000 OO OC�OOODOLJ0�0 00 I]C���OED0000ED �, C'ermit valid for Rha'A112 (>1 Shl'G f�1V4111FI 1 D J 00000000 ..'.'4'.:.: 0 o moor 0 0 0 0 0 0 0 ' ONLY, due . to State and 1.r�r it ,� I i�r�W�►tianres. 4 0 ALL PIPES .Board.of Health review and apprw, A I. required for =J GASB 9'84 9.67 3/4' - 1 1/2" DIA 48' BOTTOM OF SYS EL=7.5 Any . future additions/reno%mi„n%',�Iterafions to BAFFLE DOUBLE WASHED STONE 34'1 1 sewage facilities and/or strud w es/6N cI ing: D-6 COMPACTED BASE D -BOX 41' Yarmouth t ealth Dc rrruucnt 1 CR6- LAYER OF USH D STONE (H-20) LINE(S) EXITING D -BOX MUST�.���/'}Y�% SEPTIC TANK REMAIN LEVEL FOR 2-0 BEFORE PITCHING DOWN TO TYPICAL LEACH SYSTEM CROSS SECTION ':. Gi/Z'�� PRECAST REINFORCED CONCRETE LEACHING FACILITY OR 'SPEED NO SCALE CAPACITY: 2500 GALLONS PROVIDE LEVELS' SAS CONSTRUCTION �1 j („�' `9 H-20 ( ) SEPTIC SYSTEM PROFILE PROPOSED SAS CONSISTS OF SIX (7) PRE -CAST CONCRETE, 500 GALLON DRYWELL UNITS AS MANUFACTURED BY SHOREY 1 FT. EXCAVATI T TO THE INDICATED PRECAST. INC. OR PLACED SIDE -TO-SIDE IN A SA 4TH! <- ;. 1�1� A1C, 'Uate ELEVATIONS, SURROUNDED BY 1 )1iIN. IAMETER, DOUBLE -WASHED STONE; 2 IN. THICKNESS LAYER OFE9 TO 3/8PEAST �(' SHALL BE SET IN PLACE ABOVE THE INLET PIPE OR USE A SUITABLE GEOTEXTILE FILTER CLOTH; ALL INLET UNITS SHALL HAVE RISERS WITH COVERS TO WITHIN 6 INCHES OF FINISHED GRADE. / ���L/L �L 6�/` NO SCALE VSTOFF.D elevation depth (in.) horizon texture color mottling other 12.5-11.5 0-12 A. loam. sand IOYR 3/3 11.5-9.0 12-42 B loam. sand 10YR 5/6 9.0-6.5 42-72 C 1 loam. sand 10 YR 6/8 6.5-4.2 72-100 C2 loam. sand 10 YR 5/4 4.2-1.5 190 - 132 C3 med..Z d 10 YR 5/4 Parent material: glacial outwash _ Depth to Groundwater - 132" (elev. = 1.5) Tidally affected - assume high GW elev. = 2.5 PERC. TEST DATA: Max. depth of pert hole = 48 inches 12 in to 9 in. - 5 min. 39 see. 9 in. to 6 in. - 7 min 7 sec. PERC RATE = LESS THAN 5 MPI Class 1