Loading...
HomeMy WebLinkAboutEngineered Plan - 2018LEGEND ENTRY FLOOR PLAN `,�71 CUNNINGHAM, JOSEPH P 1 MERGANSER LANE WEST YARMOUTH, MA 02673 CE LOCUS MAP NOT TO SCALE )TES: 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE LOCAL RULES AND REGULATIONS. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION DESIGN AND APPROVAL BY THE BOARD OF HEALTH AND THE ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON AN ASSIGNED DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION, 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. 8. THERE ARE NO WELLS WITHIN 100' OF THE PROPOSED S.A.S. 9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE DIRECTED BY THE APPROVING AUTHORITIES. 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATION CONSTRUCTION. OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING 11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3). 12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE INSPECTED BY DESIGN ENGINEER PRIOR TO BACKFILL. 13. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND NOT CONSIDERED TO BE A PROPERTY LINE SURVEY. 14. THE ENGINEER IS NOT RESPONSIBLE FOR ANY UNDOCUMENTED SEPTIC SYSTEM COMPONENTS NOT SHOWN ON THE PLAN PARCEL ID: 49-210 PROPOSED SEPTIC SYSTEM UPGRADE PLAN 1 MERGANSER LANE, WEST YARMOUTH, MA Prepared for: Joseph Cunningham, 1 Merganser Ln, West Yarmouth, MA 02673 Engineering by: SCALE DRAWN JOB. NO. Engineering Works, Inc. 1"=20' P.T.M. 153-18 12 West Crossfield Road, Forestdole, MA 02644 DATE CHECKED SHEET NO. (508) 477-5313 4/27/18 P.T.M. 1 Of 2 NOTE: TO PREVENT BREAKOUT, FINAL GRADE SHALL NOT BE AT, OR BELOW, EL.=103.5 FOR A DISTANCE OF 15' FROM THE EDGE SEPTIC TANK PROPOSED D -BOX OF THE PROPOSED S.A.S. INSTALL RISERS & COVERS OVER INLET & INSTALL RISER & WATERTIGHT OUTLET AND SET TO 6" OF FINISH GRADE COVER SET TO 6" OF GRADE PROPOSED S.A.S. INSTALL RISER &COVER OVER ONE CHAMBER AND �� ,EXISTING T.O.F.=68.22± SET TO 3" OF F.G. TO SERVE AS INSPECTION PORT /HOUSE(j1) F.G. EL.=107.1± F.G. EL.=107.0± F.G. EL.=106.6± ff F.G. EL.=106.5± MAINTAIN 2% SLOPE OVER S.A.S. /lT.O.F.=107.4E GGA AGE L-27' L=5 ®S=1% (MIN.) S=1% (MIN.) 4"SCH40 PVC 4"SCH40 PVC 1777 2" LAYER OF 1/8" TO 1/2" , DOUBLE WASHED STONE N j �3' 0.7' LLL�� I 14" 6" LIQUID aaa0aaim aaa (OR APPROVED FILTER FABRIC) ��O' � W LA \% EXISTING 48" aaaaaaa --3/4" TO 1-1/2" DOUBLE S `�9' `�'3' LEVEL 4 4.8' 4' WASHED STONE nD ADD AAs BAFFLE INV.=103.27 PROPOSED INV.=103.10 INV.=103.93± D -BOX EFFECTIVE WIDTH = 12.8' _ T EXISTING INV.=103.00 PROP. S.A.S. f f EXISTING SEPTIC TANK 2-500 GALLON LEACHING CHAMBERS SURROUNDED WITH STONE AS SHOWN __ _ 7:75 I H-10 RATED H-10 NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE TOP CONC. ELEV.=103.8± BREAKOUT ELEV.=103.50 SEPTIC LAYOUT INVERTS, PRIOR TO INSTALLATION. INV. ELEV.=103.00 2) D -BOX SHALL BE SET LEVEL AND TRUE TO ®ease aaa®aaaaaaa GRADE ON A MECHANICALLY COMPACTED SIX as®aaaaaaao INCH CRUSHED STONE BASE, AS SPECIFIED IN BOTTOM ELEV.=101.00 4' 2 x 8.5' = 17.0' 4' 310 CMR 15.221(2). 4' OF NATURALLY OCCURRING 3) INSTALL INLET & OUTLET TEES AS REQUIRED. EFFECTIVE LENGTH = 25.0' PERVIOUS MATERIAL ® O E2 E3 E3 Ea 4) GAS BAFFLE TO BE INSTALLED ON OUTLET TEE 4' (MIN.) ABOVE G.W. AS MANUFACTURED BY TUF-TITE, ZABEL OR EQUAL. LEACHING SYSTEM SECTION ® ®®® ® ® ® E3 37" raz EST. HIGH G.W., EL=95.9 _5) USE OF THE EXISTING SEPTIC TANK IS SUBJECT It W ® Ea Ea E3 E3 U E3 EaTO THE APPROVAL OF THE BOARD OF HEALTH N z ®®®®®®®® OR IT'S AGENT. SEPTIC SYSTEM PROFILE N.T.S. 102" DESIGN CRITERIA SOIL LOG 4" KNOCKOUT NUMBER OF BEDROOMS: 2 BEDROOMS DATE: APRIL 19, 2018 20" DIA. COVER SOIL EVALUATOR: PETER McENTEE PE(SE#1542) SOIL TEXTURAL CLASS: CLASS I WITNESS: AMY VON HONE RS HEALTH AGENT 4' KNOCKOUT 4" KNOCKOUT 58" DESIGN PERCOLATION RATE: 3 MIN/IN ELEV. TP DEPTH DAILY FLOW: 220 G.P.D. 106.9 0 DESIGN FLOW: 330 G.P.D. FILL 4" KNOCKOUT GARBAGE GRINDER: NO -not allowed with design 105.4 ! 18" LEACHING AREA REQUIRED: (330) = 445.9 S.F. AbLOAMYD 500 GALLON CAPACITY, H-10 LOADING 4A .74 104.9 24" CHAMBERS EXISTING SEPTIC TANK: 1000 GALLON CAPACITY B LOAMY SAND PROPOSED D -BOX: 1 INLET, 3 OUTLETS, H-10 RATED PERC 1OYR 5/8 24"/42" N.T.S. 103.9 G 40" PROPOSED SEPTIC SYSTEM UPGRADE PLAN USE 2-500 GALLON LEACHING CHAMBERS IN SERIES 1 MERGANSER LANE, WEST YARMOUTH, MA SURROUNDED BY DOUBLE WASHED STONE ON ALL SIDES FINE SAND Prepared for: Joseph Cunningham, 1 Merganser Ln, West Yarmouth, MA 02673 SIDEWALL AREA: 2(12.8' + 25.0') X 2 = 151.2 S.F. 2.5Y 5/3 Engineering by: SCALE DRAWN JOB. NO. BOTTOM AREA: 12.8' x 25.0' = 320.0 S.F. 95.9 EST HIGH GW = 132" REDOX TOTAL AREA: 471.2 S.F. 95.4 138" Engineering Works, Inc. 1 "=20' P.T.M. 153-18 .............................................................. NO GROUNDWATER ENCOUNTERED PERC RATE <3 MIN./INCH 12 West Crossfield Road, Forestdale, MA 02644 DATE CHECKED SHEET No. DESIGN FLOW PROVIDED: 0.74 GPD/SF(471.2 SF) = 348.7 GPD (508) 477-5313 4/27/18 P.T.M. 2 of 2