Loading...
HomeMy WebLinkAboutEngineered Plan - 2013ALWAYS DIG SAFE PRIOR TO CONSTRUCTION --UTILITY LOCATIONS SHOWN INCOMPLETE. if 01- TH 1 W WJE -E- ___ U _____ x 9.5 x8,7 8- IB x- 0 N /F MANN N /F CHIPMAN 31,5 S 79.15w /X�! 10000 :�'-`;: X . 31.4 :•.co cn•:. bashes ::� .7 31. in this area Where 31.4 -X \ 31,8 Cars a��ow X trees 31.21 Deckl ; 1 and x 32.0 2 31,8 Y !�,30.60 Above 1 . �vE _ A;- 1? P DDR _ _- - 31.11 Grnd 31.7 N_ , 1,5 'U'75 7 pOH o / / Wd 31,57 z • i 30.07 to Decks LOT 33,***.* � _ _-A d 0'N •z ------ _ J 31\,512j140±S.F.-.. o S 31 Pato -SnU1 31.3 o n? 31, �U \!ice" X 31, 30.cj4Fi ® 9.74 1.4 I m 9 0 fr1 N N� r - j <V it 0 9.88 `1 I rT� 3 ° 31.0 SERVE \ I II 30.12 x L TH 1 1.• I I 1 0,6 1.1 � I II T � � x 31,2 rn I0'�010 1 I I I I I I I I I I I 1 I o' Field \ Location l 0 i1,1 x 3 0. 8 /71 Location± from As -Built may encroach upon leachin`1 Mp 1-1 30. . 30.7 Qom' 30.72 --� 24<' 30,4,^',! \ x O.S. 3� , 30,80 \ 30,8'd30.8 ®9,89 30.143 35 I I I I V I I I �I 0-9,94 L \ \® 9.46 O BENCH MARK --TOP OF MAG NAIL 30,00 IN SIDEWALK= 30.80 ASSIGNED LEGEND ' TEST HOLE LOCATION, NUMBER WATER LINE MARKINGS UNDERGROUND ELECTRIC WIRES (IF SHOWN) OVERHEAD ELECTRIC WIRES (IF SHOWN) GAS LINE MARKINGS EXISTING & PROPOSED ELEVATIONS ('X' MARKS POINT) EXISTING CONTOUR PROPOSED CONTOUR UTILITY POLE (IF SHOWN) EXISTING DRAINAGE CATCH BASIN FENCE (IF SHOWN, NOT ALL SHOWN) TREE (IF SHOWN, NOT ALL SHOWN) 4 BEDROOM OPTION 1 "=20' 26.75± Top Foundation Cesspool reported Under wood Patio/ ScreenHouse PROPOSED SEWER CROSSES BURRIED HOT TUB ELECTRIC 30.0 ' 29.67 0 N Inv.= o. _8- �o RESERVE_ -- 13 HI-CAP'S=633 S.F. =468 GPD Invert 29.75 Existing Cast Iron Invert 29.15 Existing PVC S=1,4"/ft 9" min. cover r NOT TO SCALE LOCATION MAP TEST HOLE 1 DEPTH (inches) ELEV.(feet) p 31.2 A layer 1Oyr 3/3 8" sandy loam PERC RATE: Z 3 V", _<2!--W'/inch (C layer) SOIL SURVEY(1993): Carver coarse sand 22„ GEOLOGIC MAP(1986): Harwich outwash plain deposits 10 HIGH CAPACITY 42»� Invert 28.70 INFILTRATORS (H-20) Proposed Use Gas Baffle Invert 28.7 Invert 28.33 Top Units Proposed 0 Filter Cloth I Proposed S=1,8"/ft3" Max. S=1/8"/ft p -inspection Port 'invert 28.95 1500 Gal. T Proposed Septic Tank ----- --- T ills 132 I Invert 28.50 Invert 28.33 27.4 6" Stone or compaCt ProposedProposed 7.2' Bottom I 17 10' i i-19' L- O,- DESIGN DATA bottom 1 H 1=zu.L 8 layer 10yr 5/6 I sandy loam f C layer 10yr 6/6 Ij medium sand no water 29.4 D.2 BEDROOMS: 3 (SEE MODIFIED CERTIFICATION FOR GENERAL USE --REV. 6/30/10) _GARBAGE GRINDER:- _. _ _ _ _ . No _� _ _ EXCAVATE TWO 2'-10" WIDE AND 31'-3" LONG TRENCHS, AS REQUIRED CAPACITY: 330 GPD SHOWN. WSE--TEN-Hi-P--Ff 20-1NFlLTRA-TORS. ` FILTE-R-CLOTH SEPTIC TANK: 1500 GAL. IS RECOMMENDED OVER UNITS. BACKFILL TO TOP OF UNITS EFFECTIVE TRENCH LEACHING AREA: 486.8 SF WITH CLEAN SAND FROM A GRAVEL PIT, OR VIRGIN C LAYER FROM .SITE MAY .BE USED .IF .IT CAN BE KEPT CLEAN AND 7.79 SF/LF X 6.25'/UNIT=48.69 S.F/UNIT FREE OF TOP AND. SUBSOIL. 10 UNITS X 48.69 SF/UNIT=486:8 SF(EFFECTIVE) DESIGN CAPACITY: 360 GPD _[(486.8 SF) X .74 GPD/SF] / NO DOOR � env.=co.ti 1...Prop. 3 1 Inv.=28.25 Prop. � Inv.=28.16 x Prop. DOOR MAY BE PUT BETWEEN DB RM D BDRM KIT DNRM = 2 FINISHED ROOMS ,KITCHEN AND DINING � IN BASEMENT ROOM TO GIVE 4 BEDROOMS FLOOR PLAN wRM BDRM (NO HEAT) NOT TO SCALE THIS PLAN IS A VALID COPY ONLY IF IT BEARS AN ORIGINAL RED STAMP AND SIGNATURE. HEALTH AGENT APPROVAL DATE �ar>ramout:, Health Department izZ� �� [2[9c I��W0ED _t gate SITE PLAN - MAR I 92.013 FOR rY MARGARET A. SANDERS LOT 33, 4 RAYMOND AVE, S. YARMOUTH, MA MARCH 15, 2013 SCALE; 1 "=20' RONALD J. CADILLAC, PLS, RS, P.C. PROFESSIONAL LAND SURVEYOR & REGISTERED SANITARIAN P.O. BOX 258 WEST YARMOUTH, MA 02673 @2013. BY R.J. CADILLAC (508) 775-9700 PAGE 1 OF 1 J JOB NO. Y13-09 NOTES Sanders.dwg 1. LOCUS IS A.M. 79, PARCEL 41. FB28/40 SB13/07 2. ELEVATIONS SHOWN ARE ASSIGNED. 3. LOCUS IS IN FLOOD ZONE C ON FIRM DATED JUNE 17, 1986. 4. ALL PIPES TO BE 4" SCH 40, AND PITCHED AT 1/4" PER FOOT. (UNLESS NOTED) 5. MUNICIPAL WATER IS AVAILABLE. LOTS WITHIN 100' ARE ON TOWN WATER. 6. COMPONENTS TO BE AASHTO H-10, UNLESS NOTED. 7. INLET TEE TO PROJECT DOWN 13", OUTLET TEE DOWN 14". 8. IF TWO OR MORE LINES, WATER TEST D -BOX FOR EQUAL FLOW D -BOX EXIT PIPES TO BE LEVEL FOR FIRST TWO FEET. 9.DEPTH OF COMPONENTS NOT TO EXCEED 3', OR VENTING MUST BE PROVIDED. N /F I COVERS: BUILD UP COVERS TO WITHIN 6" OF GRADE --2 ON TANK, 1 ON D -BOX, 2 ON LEACHING. MELO 10. DOUBLE WASH 3/4 TO 1 1/2" STONE (IF NEEDED) WITH 2" MIN. 1/8 TO 1/2" PEA STONE ON TOP. 11. IF UNSUITABLE SOILS, OR SOILS DIFFERING FROM THE SOIL LOG ARE FOUND, CONTACT THE BOARD OF HEALTH, OR R.J. CADILLAC. 12. IF AN OVERDIG IS CALLED FOR BELOW, FILL MATERIAL. FOR 5' AROUND AND UNDER LEACHING IS TO BE CLEAN GRANULAR SAND MEETING SPECIFICATIONS OF 310 CMR 15.255(3). 13. PUMP AND FILL ANY EXISTING CESSPOOL/LEACHPIT. REMOVE ANY CLOGGED SOIL, BLOCK, AND STONE IN LEACH AREA, AND DISPOSE OF AS DIRECTED BY HEALTH AGENT. NO GRADE CHANGES 14. ALL CONSTRUCTION TO MEET TITLE 5 AND LOCAL REGULATIONS. ARE PROPOSED TEST HOLE DATE: March 7, 2013 BENCH MARK -SPIKE SET DOWN 1" PERFORMED BY: Ron Cadillac, Soil Evaluator IN LAWN=31.57 ASSIGNED WITNESSED BY: Amy Von Hone, RS, CHO 26.75± Top Foundation Cesspool reported Under wood Patio/ ScreenHouse PROPOSED SEWER CROSSES BURRIED HOT TUB ELECTRIC 30.0 ' 29.67 0 N Inv.= o. _8- �o RESERVE_ -- 13 HI-CAP'S=633 S.F. =468 GPD Invert 29.75 Existing Cast Iron Invert 29.15 Existing PVC S=1,4"/ft 9" min. cover r NOT TO SCALE LOCATION MAP TEST HOLE 1 DEPTH (inches) ELEV.(feet) p 31.2 A layer 1Oyr 3/3 8" sandy loam PERC RATE: Z 3 V", _<2!--W'/inch (C layer) SOIL SURVEY(1993): Carver coarse sand 22„ GEOLOGIC MAP(1986): Harwich outwash plain deposits 10 HIGH CAPACITY 42»� Invert 28.70 INFILTRATORS (H-20) Proposed Use Gas Baffle Invert 28.7 Invert 28.33 Top Units Proposed 0 Filter Cloth I Proposed S=1,8"/ft3" Max. S=1/8"/ft p -inspection Port 'invert 28.95 1500 Gal. T Proposed Septic Tank ----- --- T ills 132 I Invert 28.50 Invert 28.33 27.4 6" Stone or compaCt ProposedProposed 7.2' Bottom I 17 10' i i-19' L- O,- DESIGN DATA bottom 1 H 1=zu.L 8 layer 10yr 5/6 I sandy loam f C layer 10yr 6/6 Ij medium sand no water 29.4 D.2 BEDROOMS: 3 (SEE MODIFIED CERTIFICATION FOR GENERAL USE --REV. 6/30/10) _GARBAGE GRINDER:- _. _ _ _ _ . No _� _ _ EXCAVATE TWO 2'-10" WIDE AND 31'-3" LONG TRENCHS, AS REQUIRED CAPACITY: 330 GPD SHOWN. WSE--TEN-Hi-P--Ff 20-1NFlLTRA-TORS. ` FILTE-R-CLOTH SEPTIC TANK: 1500 GAL. IS RECOMMENDED OVER UNITS. BACKFILL TO TOP OF UNITS EFFECTIVE TRENCH LEACHING AREA: 486.8 SF WITH CLEAN SAND FROM A GRAVEL PIT, OR VIRGIN C LAYER FROM .SITE MAY .BE USED .IF .IT CAN BE KEPT CLEAN AND 7.79 SF/LF X 6.25'/UNIT=48.69 S.F/UNIT FREE OF TOP AND. SUBSOIL. 10 UNITS X 48.69 SF/UNIT=486:8 SF(EFFECTIVE) DESIGN CAPACITY: 360 GPD _[(486.8 SF) X .74 GPD/SF] / NO DOOR � env.=co.ti 1...Prop. 3 1 Inv.=28.25 Prop. � Inv.=28.16 x Prop. DOOR MAY BE PUT BETWEEN DB RM D BDRM KIT DNRM = 2 FINISHED ROOMS ,KITCHEN AND DINING � IN BASEMENT ROOM TO GIVE 4 BEDROOMS FLOOR PLAN wRM BDRM (NO HEAT) NOT TO SCALE THIS PLAN IS A VALID COPY ONLY IF IT BEARS AN ORIGINAL RED STAMP AND SIGNATURE. HEALTH AGENT APPROVAL DATE �ar>ramout:, Health Department izZ� �� [2[9c I��W0ED _t gate SITE PLAN - MAR I 92.013 FOR rY MARGARET A. SANDERS LOT 33, 4 RAYMOND AVE, S. YARMOUTH, MA MARCH 15, 2013 SCALE; 1 "=20' RONALD J. CADILLAC, PLS, RS, P.C. PROFESSIONAL LAND SURVEYOR & REGISTERED SANITARIAN P.O. BOX 258 WEST YARMOUTH, MA 02673 @2013. BY R.J. CADILLAC (508) 775-9700 PAGE 1 OF 1 J