Loading...
HomeMy WebLinkAboutEngineered Plan - 2005N SITE PLAN SCALE: 1 "=20' BENCH MARK ON RAIL ROAD SPIKE FOUND ELEV.=100.00' (ASSUMED) •t F-1 00.6 E# O 109 7' 4' c.I.f. _ T 6 PERK K _ w #23 MAYFLLOWER LANE 1 MOC 199.87' LOT 4 AREA = 8,208± SQ.FT gravel 40 190.88' r 100.13' W zzE Ei 0 03 79 99.83' 99.60'90.0 SPIKE M 10 1-33.5'L X 9'W X 2.0' D L. M. leachingg trench using 3 H-••20500 gal. chambers with 9910' 2' of stone on sides & 4' on ends. Jam, #11 MAYFLOWER DRIVE _. 52-66 PERK TEST & SOIL EVALUATION Date of Perc. Test & Sail Eval.: AUGUST 30, 2005 Test Performed By: GLEN E. HARRINGTON, R.S., CSE Witnessed by. LYNNE MULKEEN, AGENT FOR TO M, OF YARMOUTH Excavator: D.A. BROWN Test Hole No. 1 DEPTN SOILS ELEV. 0 99.2' 7„ to y .and Bw 10' min. from *NOTE: INSTALL GAS BAFFLE OR EQUAL ON SEPTIC TANK OUTLET TEE.�� 27' EXISTING CESSPOOL C1 house to septle tank F -M sand �\`=��J 120" 1 asre/+ 59,2 C2 ,►» sand 5 HOLE „ 1OYR6/2 NO GROUNDWATER ENCOUNTERED PERK TEST ® T.w_ #�1 PERK DEPTH -36"-54' BEG. SOAK 0 0:00 END SOAK 0 11:11 24 gole applied within 15 min. USE PERK RATE < 2 DAPI FOR DESIGN PURPOSES O W ry W C LL Desian Calculations Number of Bedrooms: 2 Garbage Grinder: GRINDER NOT ALLOWED WITH THIS DESIGN Leaching Capacity Required: 330 Gal./Day (MIN. PER TITLE V) Leaching Area Required: 330 Gal./(0.74 Gal./Sq.Ft.)=446 Sq.Ft. Proposed Leaching Structure: 1-33.51 X 9'W X 2'D Leaching Trench Leaching Area Provided: 471 Sq. Ft. Proposed Leaching Capacity. 349 gpd > 330 gpd. req'd. a-20' oow. AMM MN*4010 SML RaMR RCSD PRECAST CONCRETE PLAN VIEW 3-20' n87E covers IT 8' mh. 3' anti. Wet b auaat e• �, - --. I --- CU1LET f *M ma,. �� ses ewfua � d°rrei :j CROSS SECTION END—SECTION H-10 15QO GALLON SEPTIC TANK NOT TO SCALE USE ACME PRECAST OR EQUAL l "S.YARMOUTH" GENERAL NOTES LOCUS 1. ADDRESS: #17 MAYFLOWER LANE NO SCALE 2. ASSESSORS NUMBER: MAP 52 PARCEL 67 3. DEVELOPER'S LOT: LOT 4 4. TOPOGRAPHIC INFORMATION WAS COMPILED FROM AN ON THE GROUND INSTRUMENT SURVEY. 5. TOWN WATER IS PROVIDED TO SITE & SURROUNDING PROPERTIES. 6. REFERENCE PLAN: PLAN BOOK 88 PAGE 77-2 7. NO WETLANDS ARE LOCATED WITHIN 100 FEEL" OF SAS. 8. NO POTABLE WELLS ARE LOCATED WITHIN 150 FEET OF SAS. 9. THIS DESIGN PLAN IS TO BE USED FOR SUBJECT SITE SEPTIC INSTALLATION ONLY. CONSTRUCTION NOTES 1. Contractor is responsible for Digsafe notification and protection of all underground utilities and pipes. 2. The septic tank onj distribution box shall be set level on 6 of 3/4 —11/2" stone. 3. Backfill should be clean sand or gravel with no stones over 3" in size. 4. This system is subject to inspection during installation by Glen E. Harrington, R.S. 5. The contractor shall install this system in accordance with Title V of the Massachusetts Environmental Code and the Regulations of the Town of YARMOUTH. 6. Provide on Acme Precast H-10, 1,500 gal. septic tank, 1 H-20 5—hole D—Box and 3 H-20 500 gal. chambers or equal. 7. No vehicle or heavy machinery shall drive over the septic system unless noted as H-20 septic components. 8. Install gas baffle or equal on septic tank outlet tee end. 9. All existing inverts and site conditions shall be verified by contractor. 10. Existing CESSPOOLS to be pumped and removed. 1-2w Mm. AoaM r. WME _. 5' j a [� p 34A G3� ® C3 ® Kj 124"1 SIEEL REINFORCED PR AST CONCRETE PLAN VIEW H-20 500 gal. chambers END—SECTION H-20 500 GALLON CHAM E NOT TO SCALE USE ACME PRECAST OR EQUAL F1�� ��' �, '(N OF ISN �.\ �o �G -0.1107 O cS' �G/STEe``L qN/TAR�P� SCALE: 1 "=20' DATUM: ASSUMED OCT 0 5 2005 6 L14,QSL.-PJ` DEPT . PROPOSED SEPTIC SYSTEM UPGRADE PfePARtD FOR D. A. BROWN LANDSCAPING AT ANDERSON, 17 MAYFLOWER LANE YARMOUTH, MA PREPARED BY: GLEN E. HARRINGTON, R.S. 9 LEDA ROSE LANE MARSTONS MILLS, MA 02648 TEL: 508--428-3862 FAX: 508-428-3862 DRAWN BY: GEH SEP. 22, 2005 FILE: BROWN MAYFLOWER SHEET 1 OF 1 LEGEND *NOTE: ALL PIPES ARE TO BE 4" DIA, SCHEDULE 40 P.V.C. 10' min. from *NOTE: INSTALL GAS BAFFLE OR EQUAL ON SEPTIC TANK OUTLET TEE.�� EXISTING CESSPOOL Existing Dwelling house to septle tank �\`=��J (APPROX. LOCATION) Septks tank ower must be Flnished grade over a7atem-2% slope away wffhks 8" of flntd,sd grade TOF EL -100, 5 HOLE PROPOSED 1,500 GAL. EJUS71 c Dist Box st Grade F7ev�9g-1091 FEE] H-10 SEPTIC TANK cellar U -Sox cover must be Alin. 2'-1/6'-1/2 Vthtn 6' of bhsd grads double wa�sd stone s -.o3' 1 chamber cover must be within 8" of flnt±he4 rade g 2" min. • mcnG DENOTES EXISTING wall . LeW for 2" 24 PROPOSED . s..ot -y.-97.4'± X 104.46 SPOT GRADE 1,500 SEPTIC TANK' =' 20 $.93' 95 EXISTING CONTOUR H-10 GAS 8 E _ CZ C2 o"► L00AFFl m , ,s• ,yLEACH ren ev.� 93' APPROX. LOCATION a TRENCH rt (V min required) EXISTING WATER LINE B' OF 3/4'-11/2• STONE i h ® � ,D=M OF T.H.#'I ELEV.-87.87' 6 6 APPROX. LOCATION SYSTE�vI PRQFILE EXISTING WATER LINE e' of 3/4"-11/2' "Es Not to Scale USE ACME PRECAST OR EQUAL F1�� ��' �, '(N OF ISN �.\ �o �G -0.1107 O cS' �G/STEe``L qN/TAR�P� SCALE: 1 "=20' DATUM: ASSUMED OCT 0 5 2005 6 L14,QSL.-PJ` DEPT . PROPOSED SEPTIC SYSTEM UPGRADE PfePARtD FOR D. A. BROWN LANDSCAPING AT ANDERSON, 17 MAYFLOWER LANE YARMOUTH, MA PREPARED BY: GLEN E. HARRINGTON, R.S. 9 LEDA ROSE LANE MARSTONS MILLS, MA 02648 TEL: 508--428-3862 FAX: 508-428-3862 DRAWN BY: GEH SEP. 22, 2005 FILE: BROWN MAYFLOWER SHEET 1 OF 1