HomeMy WebLinkAboutBLD-18-006769NEW DECK TO BE LOCATED
IN THE EXISTING PATIO
NOTES:
LOCATION
1.) CONTRACTOR IS TO VERIFY ALL EXISTING CONDITIONS
& DIMENSIONS IN THE FIELD
20'-0" 2.) CONTRACTOR TO VERIFY ALL INTERIOR & EXTERIOR MATERIALS,
DETAILS, & FINISHES IN THE FIELD WITH OWNER
A 3.) SEE CERTIFIED PLOT PLAN FOR ALL EXISTING & PROPOSED DETAILS
y
4.) ALL CONSTRUCTION TO CONFORM TO 780 CMR MASSACHUSETTS
STATE BUILDING CODE, 9TH EDITION AMENDEMENT & IRC2015
5.) 110 MPH EXPOSURE B WIND ZONE
6.) FOLLOW ALL MANUFACTURER'S SPECIFICATIONS FOR INSTALLATION OF
ALL SIMPSON COMPONENTS
7.) ALL CONCRETE USED FOR FOUNDATION WALLS, FOOTINGS & SLABS
TO BE 3000 PSI
NEW N 8.) VERIFY ALL PLUMBING & ELECTRICAL DETAILS WI OWNERS ON THE SITE
DURING FRAMING CONSTRUCTION
DECK
'OWN OF YARMOUTH
REVIEWED FOR BUILDING AND ZONING CODE COMPLI-
ANCE. ERRORS OR Oiv"MISSIONS DO NOT RELIEVE THE
APPLICANT FROM THE RESPONSIBILITY OF 'AS BUILT"
COMPLIANCE.
DATE: 6" " 7 - /p
EXIST. BUILDING OFFICIAL
HOUSE
FILE COPY
FLOOR PLAN -
20' -0"
10" DIA. CONCRETE SONOTUBES
6'-8" 6'-8" 6'-8" ol ON 24" DIA. BIGFOOT FOOTINGS
TO 4'0" BELOW GRADE. USE
tEM
SIMPSON ABU66 POST BASE
ALTERNATE FOOTING:
/ 3- P.T. 2 x 1/ / DIAMOND PIERS
n
i INSTALL FLASHING UNDER
HOUSEWRAP & DECKING
VERIFY DECKING
o P.T. 2 x 10's @ 16" D.C. cv I MATERIALS W/
DECKING OWNERS
�;I W/MID-SPAN BLOCKING
v_7
3- P.T. 2 x 10 BEAM
FFLOORJOISTS , W/ PVC FASCIA P.T. 2 x 10's a 16" o.c.
P.T. 2 x 10's @ 16" o.c.
10" DIA. CONCRETE SONOTUBES q
ON 24" DIA. BIGFOOT FOOTINGS �
INSTALL PEEL & STICK TO 4'0" BELOW GRADE. USE
RUBBER MEMBRANE SIMPSON ABU66 POST BASE
BETWEEN LEDGER &
SHEATHING ALTERNATE FOOTING:
DIAMOND PIERS
P.T. 2 x 10 LEDGER BOARD SCREWED TO P.T. 2 x 10 LEDGER BOARD SCREWED TO
SOLID BLOCKING W/ (2) LEDGERLOK SCREWS SOLID BLOCKING W/ O RD SCREWED
SCREWS P.T. 2 x 10 LEDGER BOARD SCREWED TO
16" o.c. W/ ZMAX LU210 JOISTS HANGERS 16" ID W/ IMAX LU210 JOISTS HANGERS SOLID BLOCKING W/ (2) LEDGERLOK SCREWS
INSTALL SIMPSON DTT1Z TENSION TIES 16" o.c. W/ ZMAX LU210 JOISTS HANGERS
EXIST. AT (4) LOCATIONS FROM HOUSE TO DECK INSTALL SIMPSON DTT1Z TENSION TIES, INSTALL SIMPSON DTT1Z TENSION TIES
JOIST (1) EACH END AT (4) LOCATIONS FROM HOUSE TO DECK AT (4) LOCATIONS FROM HOUSE TO DECK
HOUSE JOIST (1) EACH END JOIST (1) EACH END
DECK DETAIL A SECTION @ NEW DECK-
.FOOTING/FRAMING
ECKFOOTING/FRANIING PLAN-
ij
THE DESIGNER SHALL BE NOTIFIED IF ANYiERRORS OR OMISSIONS ARE FOUND ON SCALE DRAWING NO.
THESE DRAWINGS PRIOR TO START OF �I
_C OT U I T BAY DESIGN, LLC NEW O CONSTRUCTION. THE BUILDING CONTRACTOR 11 I I I
43 B R E V V STE 1 \ ROAD
WILL BE RESPONSIBLE FOR THE CONTENT 1/4 1 —011
O
/� (� IN THESE DRAWINGS IF CONSTRUCTION
MAS H P E E 1 V IA. 0204 �J /, 7 CRANBERRY LANE iCOMMENCES WITHOUT NOTIFYING THE
(Vr+ DESIGNER OF ANY ERRORS OR OMISSIONS. DATEAlf IL
1 II OF THE OWNER NOTEDTHESE DRAWINGS ARE . ANY OTHER USE OFOLELY FOR THE j
PH . (508 274-1(�1 00 THESE DRAWINGS REQUIRES THE WRITTEN iI
FAX50 539-°4O2YARMOUTH: CONSENT OF THE DESIGNER UNDER THE 4/30/2018
( ) SOUTH ! ARCHITECTURAL COPYRIGHT PROTECTION
i ACT OF 1990.