Loading...
HomeMy WebLinkAboutBLD-18-006769NEW DECK TO BE LOCATED IN THE EXISTING PATIO NOTES: LOCATION 1.) CONTRACTOR IS TO VERIFY ALL EXISTING CONDITIONS & DIMENSIONS IN THE FIELD 20'-0" 2.) CONTRACTOR TO VERIFY ALL INTERIOR & EXTERIOR MATERIALS, DETAILS, & FINISHES IN THE FIELD WITH OWNER A 3.) SEE CERTIFIED PLOT PLAN FOR ALL EXISTING & PROPOSED DETAILS y 4.) ALL CONSTRUCTION TO CONFORM TO 780 CMR MASSACHUSETTS STATE BUILDING CODE, 9TH EDITION AMENDEMENT & IRC2015 5.) 110 MPH EXPOSURE B WIND ZONE 6.) FOLLOW ALL MANUFACTURER'S SPECIFICATIONS FOR INSTALLATION OF ALL SIMPSON COMPONENTS 7.) ALL CONCRETE USED FOR FOUNDATION WALLS, FOOTINGS & SLABS TO BE 3000 PSI NEW N 8.) VERIFY ALL PLUMBING & ELECTRICAL DETAILS WI OWNERS ON THE SITE DURING FRAMING CONSTRUCTION DECK 'OWN OF YARMOUTH REVIEWED FOR BUILDING AND ZONING CODE COMPLI- ANCE. ERRORS OR Oiv"MISSIONS DO NOT RELIEVE THE APPLICANT FROM THE RESPONSIBILITY OF 'AS BUILT" COMPLIANCE. DATE: 6" " 7 - /p EXIST. BUILDING OFFICIAL HOUSE FILE COPY FLOOR PLAN - 20' -0" 10" DIA. CONCRETE SONOTUBES 6'-8" 6'-8" 6'-8" ol ON 24" DIA. BIGFOOT FOOTINGS TO 4'0" BELOW GRADE. USE tEM SIMPSON ABU66 POST BASE ALTERNATE FOOTING: / 3- P.T. 2 x 1/ / DIAMOND PIERS n i INSTALL FLASHING UNDER HOUSEWRAP & DECKING VERIFY DECKING o P.T. 2 x 10's @ 16" D.C. cv I MATERIALS W/ DECKING OWNERS �;I W/MID-SPAN BLOCKING v_7 3- P.T. 2 x 10 BEAM FFLOORJOISTS , W/ PVC FASCIA P.T. 2 x 10's a 16" o.c. P.T. 2 x 10's @ 16" o.c. 10" DIA. CONCRETE SONOTUBES q ON 24" DIA. BIGFOOT FOOTINGS � INSTALL PEEL & STICK TO 4'0" BELOW GRADE. USE RUBBER MEMBRANE SIMPSON ABU66 POST BASE BETWEEN LEDGER & SHEATHING ALTERNATE FOOTING: DIAMOND PIERS P.T. 2 x 10 LEDGER BOARD SCREWED TO P.T. 2 x 10 LEDGER BOARD SCREWED TO SOLID BLOCKING W/ (2) LEDGERLOK SCREWS SOLID BLOCKING W/ O RD SCREWED SCREWS P.T. 2 x 10 LEDGER BOARD SCREWED TO 16" o.c. W/ ZMAX LU210 JOISTS HANGERS 16" ID W/ IMAX LU210 JOISTS HANGERS SOLID BLOCKING W/ (2) LEDGERLOK SCREWS INSTALL SIMPSON DTT1Z TENSION TIES 16" o.c. W/ ZMAX LU210 JOISTS HANGERS EXIST. AT (4) LOCATIONS FROM HOUSE TO DECK INSTALL SIMPSON DTT1Z TENSION TIES, INSTALL SIMPSON DTT1Z TENSION TIES JOIST (1) EACH END AT (4) LOCATIONS FROM HOUSE TO DECK AT (4) LOCATIONS FROM HOUSE TO DECK HOUSE JOIST (1) EACH END JOIST (1) EACH END DECK DETAIL A SECTION @ NEW DECK- .FOOTING/FRAMING ECKFOOTING/FRANIING PLAN- ij THE DESIGNER SHALL BE NOTIFIED IF ANYiERRORS OR OMISSIONS ARE FOUND ON SCALE DRAWING NO. THESE DRAWINGS PRIOR TO START OF �I _C OT U I T BAY DESIGN, LLC NEW O CONSTRUCTION. THE BUILDING CONTRACTOR 11 I I I 43 B R E V V STE 1 \ ROAD WILL BE RESPONSIBLE FOR THE CONTENT 1/4 1 —011 O /� (� IN THESE DRAWINGS IF CONSTRUCTION MAS H P E E 1 V IA. 0204 �J /, 7 CRANBERRY LANE iCOMMENCES WITHOUT NOTIFYING THE (Vr+ DESIGNER OF ANY ERRORS OR OMISSIONS. DATEAlf IL 1 II OF THE OWNER NOTEDTHESE DRAWINGS ARE . ANY OTHER USE OFOLELY FOR THE j PH . (508 274-1(�1 00 THESE DRAWINGS REQUIRES THE WRITTEN iI FAX50 539-°4O2YARMOUTH: CONSENT OF THE DESIGNER UNDER THE 4/30/2018 ( ) SOUTH ! ARCHITECTURAL COPYRIGHT PROTECTION i ACT OF 1990.