HomeMy WebLinkAboutEngineered Plan - 2018ii r ASSESSORS MAP: PARCEL: �• 7 FLOOD ZONE: f167 i977�14f40 � REFERENCE: LOCATION MAP � -- res 4'• e; ' 100� 000 G"0 • i / / MZ. � 1 .. 40W X35; oaf . F ! .t 1TEST : HOLE! LOGS, j CIO,I) The installation shall eomp� Mill Title V' nal Town of �p 1v - Board of So IL',` EVALUATOR ; TMIQ I leallh Regulations. I WITNESS 11,t .� .. _;.. 2) ,The 'instalier'shallverify the location of utilities, sewer inverts and septic DATE r rVv'; :,; . .. . Z4 LP components prior to installation and setting base elevations. PERCOLAT ON RATE s z'�NI t l 3) All gravity septic -piping to be 4 inch Sch 40 PVC at 1/8" per foot. Thb first ,.. two reel out of the d -box to the leuehing shall be level. TH= TH -2 q) This plan is not to be utilized for property line determination nor any other purpose other than the proposed system installation. L r 5) All septic components must meet Title V specifications. O 6) "Parking shall not be constructed over 1-f 10 septic components. 4"Mi,mvo The property is bounded by property -corners and property lines. t 8) The property owner shall review design considerations to approve of total design. flow�and numbet• of bedrooms to be considered for design. Receipt , of payment for the plan and installation based on the plan shall be deemed ' l i. approval of the design flow by the owner. G 9) . The 'existing leaching or cesspools shall be pumped and filled with material i Z 7 per Title V abandonment procedures. Those within the proposed SAS shall be removed along with contaminated soil and replaced with clean sand per Title V specs. ' 10) System components to be 10 feet from water line. Sewer lines crossing the Water line shall be sleeved with 4 inch SCI 140 PVC with ends grouted if r 1"410 �2wo w� , applicable. The proposed SAS is being installed below the water service line.' The line is to be sleeved as aforementioned and maintained in place. SEPTIC SYSTEM DESIGN 11) If a garbage grinder exists it is to be removed and is the responsibility of the owner to ensure such. ! 12)The installer is to takecaution'in excavation around the gas line ifsuch FLOW'ESTIMATE bxists. `13) The installer shall veri the location, quantity and elevation of the sewer ;BEDROOMS AT `Ili GAL/DAY/BEDROOM -GAL/DAY �'. ; lines exiting the dwelling" rior to the installation. . I 14) This plan is representative only that a system can fit on a property meeting SEPTIC TANK I Title V requirements. GAL/DAY x 2 DAYS g" GAL �E l _ //�{����.. ��jyy J�7 ��J� \{� //// �y'�`w{y,' �__.�t ; USE :%GA�L011•�SEPTIC_TANK — v.• Fla-—--iblQ�_---- ((� >V-w!:.+2- SOIL'ABSORPT ON SYSTER. ; • � . �� ° , ' "r ` batt+ °���s�, � —_ { _ - DAVID i � r _ s I DE''"AREA R " % c. MA ort �_ BOTTOId ARCA: Z, /5 p S D No. 1066 o-y 73t' t ,' STE?�� • � I �,tNI TAR F� ���,".�.•�-- P.�". I•C SYSTEM SECT I ON ; �ANV�- w6 - ����. �) I (�4 101 7, ; ,k.,iti, •, �'� �� Im 59 A 6 L37 , qtr KARP&QRZ �t t ` GALv SEPTIC TANK 212ENG1 — r (' :U - o © M S ITE AND SEWAGE PLAN ' ► LOCAT I ON � �Z l,�l�•1 Y rrt�3outh IlealiM I)�•partnrcnt . t �C�.4allkiloPREPARED FOR a nG �fym CT ,Name Date SCALE: DAV I D' B MASON I DATE: Z� i - DBC ENVIRONMEN�fAL DESIGNS I�CALTii AGENT EAST: SANUW I M MA DATE (508) 833.2177 �I f i i ,i i I '1 I� I I i � l II i I l I i� I,