HomeMy WebLinkAboutEngineered Plans - 2018r
PROPOSED S.A.S.-
ADS Arc36 HD Unit
4 ROWS OF 5 UNITS
%BM -1 100,14 1 .-7��
MAGNETIC NAIL SET l +•����� i�C'
EL. =100.00 99, �A( �� \
1�
100,00 TP + 99.13
\1
ate. DECK
99,5
99.99 �G
i
EXISTING S.A.S.
-
J FLOW DIFFUSORS &
STONE, TO BE REMOVED
(see note 11)
OF MgSsgcya
o PETER T.
McENTEE
o CIVIL
No. 35109
G 99,04
99'81to o -{- 99.09
o
9 .38
99.64
HOUSE(1138)
T.O.F.=99.4±
9948 LOT 1
5,900
CBSEAL
99.32
98.84 q
�3
20.
98,40
r
a
EXISTING SEPTIC TANK
98.51
X
TOP OF TANK, EL. = 97.61 f
98.60
::11TBM-2
INV. (OUT)=96.28BIVI1
�9 06
EXISTING GAS SERVICE
---e.H.I--OVERHEAD
COR./CONC. PATIO
EL. = 99.06
L
HOUSE(1138)
T.O.F.=99.4±
9948 LOT 1
5,900
CBSEAL
99.32
98.84 q
�3
20.
98,40
r
a
98.63
OWNER OF RECORD
WEIGEL, HOWARD J
WEIGEL, ROSEMARY B
38 LAKE ROAD WEST
WEST YARMOUTH, MA 02673
LEGEND
- - 100 - -
EXISTING CONTOUR
x 100.98
EXISTING SPOT GRADE
W
EXISTING WATER SERVICE
G
EXISTING GAS SERVICE
---e.H.I--OVERHEAD
� c
TEST PIT
L
LOCUS
0
0
w
Y
Ni
BUCK
ISLAND
RD
v.
s� .
e
�.
01
�o
cAP
d
a
�.'..
.
'.•�
•. R�.�,.
Y s ec
E
98.63
OWNER OF RECORD
WEIGEL, HOWARD J
WEIGEL, ROSEMARY B
38 LAKE ROAD WEST
WEST YARMOUTH, MA 02673
LEGEND
- - 100 - -
EXISTING CONTOUR
x 100.98
EXISTING SPOT GRADE
W
EXISTING WATER SERVICE
G
EXISTING GAS SERVICE
---e.H.I--OVERHEAD
WIRES
TEST PIT
BENCHMARK
N
®
rLOCUS
LOCUS
0
0
w
Y
Ni
BUCK
ISLAND
RD
�o
cAP
LOCUS MAP
NOT TO SCALE
GENERAL NOTES:
1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL
BOARD OF HEALTH AND THE DESIGN ENGINEER.
2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS
OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE
LOCAL RULES AND REGULATIONS, EXCEPT AS REQUESTED BELOW:
1� -310 CMR 15.405(1)(h):
1) A 1' reduction to the required 5' separation between maximum
O seasonal high groundwater and bottom of S.A.S., for 4' sepataion.
3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR
TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE
DESIGN ENGINEER.
4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING
FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN
ENGINEER BEFORE CONSTRUCTION CONTINUES.
5. ALL ELEVATIONS BASED ON AN ASSUMED DATUM.
6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF
THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF
HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION.
7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE.
8. THERE ARE NO PRIVATE WELLS WITHIN 100' OF THE PROPOSED S.A.S.
9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS
AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE
DIRECTED BY THE APPROVING AUTHORITIES.
10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE
THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING
CONSTRUCTION.
11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS
IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND
REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3).
12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE
INSPECTED BY HEALTH DEPARTMENT PRIOR TO BACKFILL.
PARCEL ID: 58-280
PROPOSED SEPTIC SYSTEM UPGRADE PLAN
38 LAKE ROAD WEST, WEST YARMOUTH, AM
Prepared for: Howard Weigel, 38 Lake Road -West, W. Yarmouth, MA 02673
Engineering by: Surveyring by: SCALE DRAWN JOB. NO.
Engineering Works, Inc. JC Engineering, Inc. 1 "=20' P.T.M. 163-18
12 West Crossfield Road 2854 Cranberry Hwy. DATE CHECKED SHEET N0.
Forestdole, MA 02644 E.Wareham, MA 02538
(508) 477-5313 (508) 273-0377 5/26/18 P.T.M. 1 Of 2
NOTE: TO PREVENT BREAKOUT, THE PROPOSED
FINISH GRADE SHALL NOT BE < EL.96.4
FOR A DISTANCE OF 15' AROUND THE
SEPTIC TANK PROPOSED D -BOX
INSTALL RISERS INSTALL RISER & WATERTIGHT
PERIMETER OF THE S.A.S.
PROPOSED S.A.S.
SHED,
& COVERS OVER INLET
&
INSTALL 1 INSPECTION PORT(MIN.)
,SHED
OUTLET AND SET TO 6" OF FINISH GRADE COVER SET TO 6" OF GRADE
AT END OF S.A.S.
BHJ
9.41
TLE.=99.0± fF.G. EL.=98.81
TING
F.G. EL.=98.81
f
F.G. EL.=99.0±
� _______-35 22 .9
MAINTAIN 2% GRADE (MIN.) OVER S.A.S.
4 ,�6• DECKTING
•(9 r
'
_ '
MIN.)
INSPECTION PORT
ONE (MIN.)
N� PROP. T.O.F.HOU99 48
- S.A.S.
�� O �
®S=1%1(MIN.) ®s=1%
r
4"SCH40 PVC 4"SCH40 PVC
16"I
��
14"
8
7.13" TO
�Y✓
EXISTING 48" UQUID
��
INVERT
r t
11.3
k.- -" 34.5
�'��
INV.=96.16 PROPOSED INV.=95.99
4 ROWS OF 5 UNITS AT 5.0'/UNIT = 25.0'
INV.=96.28± D -BOX
SYSTEM (PROFILE)
EXISITNG SEPTIC TANK
EXISITNG INV.=95.93
SOIL ABSORPTION
S.A.S. LAYOUT
ESTABLISH VEGETATIVE COVER
BACKFILL WITH CLEAN NATIVE OR
NOTES:
PERC' SAND TO TOP OF CHAMBERS
_
15.5" �I (3) 5" DIA.OUTLETS
1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE
INVERTS, PRIOR TO INSTALLATION.
2) D -BOX SHALL BE SET LEVEL AND TRUE TO
"• " • `
BREAKOUT=TOP s•..• '•..: •..:'...
TOP ELEV.=96.41
INV. ELEV.=95.93O
'
"
12"
GRADE ON A MECHANICALLY COMPACTED SIX
5.5"
g"
INCH CRUSHED STONE BASE, AS SPECIFIED IN
BOTTOM ELEV.=95.33- :
310 CMR 15.221(2).
4' (MIN.) ABOVE G.W. 2.83
H-10 LOADINGT
3) INSTALL INLET & OUTLET TEES AS REQUIRED.
WITH VARIANCEEFFECT1VE WIDTH=11.3'
D -BOX 2"
4) GAS BAFFLE TO BE INSTALLED ON OUTLET TEE
4' OF NATURALLY OCCURRING
AS MANUFACTURED BY TUF-TITE, ZABEL OR EQUAL.
PERVIOUS MATERIAL
SUITABLE SOILS
5) USE OF THE EXISTING SEPTIC TANK IS SUBJECT
NO G.W., EL=91.3
T AS SPECIFIED IN 310 CMR 255(3)
TO THE APPROVAL OF THE BOARD OF HEALTH
USE 4 ROWS OF 5 -ADS Arc36 HD UNITS WITH NO
63.5"
OR IT'S REPRESENTATIVE.
SEPTIC SYSTEM PROFILE
SEPARATION BETWEEN EACH ROW & NO STONE
TYPICAL SECTION
RK
N.T.S.
13"
33.8"
SOIL LOG
DESIGN CRITERIA
DATE: MAY 8, 2018
toy
SOIL EVALUATOR: PETER McENTEE PE(SE#1542)
NUMBER OF BEDROOMS: 3 BEDROOMS
WITNESS: PHIL RENAUD HEALTH AGENT
TOP VIEW
SOIL TEXTURAL CLASS: CLASS I
.
ELEV. TP DEPTH
60"
DESIGN PERCOLATION RATE: <2 MIN/IN
99.4 A O
END CAP END CAP
LOAMY SAND
FRONT VIEW SIDE VIEW
DAILY FLOW: 330 GPD
10YR 4/2
D CAP
DESIGN FLOW: 330 GPD
98.3 B 13"
REAR /TOP VIEW
GARBAGE GRINDER: NO-S.A.S. IS NOT DESIGNED FOR
GARBAGE GRINDER
LOAMY SAND
10YR 5/8
NOTE: UNIT CONFIGURATION AND AVAILABILITY SUBJECT SIDE VIEW
LEACHING AREA REQUIRED: (330 GPD) = 445.9 SF
96.7 C 32"
TO CHANGE WITHOUT NOTICE. PRODUCT DETAIL MAY
DIFFER SLIGHTLY FROM ACTUAL PRODUCT APPEARANCE.
74 GPD/SF
PERC
20"/38"allub.
4640 TRUEMAN BLVD
HILLIARD, OHIO 43026 Are 36 DETAIL
ak
EXISITNG SEPTIC TANK: 1000 GALLON CAPACITY
ADVANCED DRAINAGE SYSTEMS. INC. UNITS MUST BE STAMPED HD
PROPOSED D -BOX: 1 INLET, 3 OUTLET (MINIMUM), H-10
RATED
FINE SAND
PROPOSED SEPTIC SYSTEM UPGRADE
PLAN
USE 4 ROWS OF 5 -ADS Arc 36 HD UNITS WITH
NO
7.5Y 7/3
38 LADE ROAD WEST, WEST YARMOUTH, AM
SEPARATION BETWEEN EACH ROW & NO STON
1
BOTTOM AREA: (GENERAL USE APPROVAL FOR 4.80 SF/LF OF UNIT)
91.3 STG. G.W. _ 97" ADJ. G.W.
Prepared for: Howard Weigel, 38 Lake Road West, W. Yarmouth,
MA 02673
(Arc36 Units) 20 UNITS x 5.0 LF x 4.80 SF/LF
= 480.0 SF
90.4 102"
Engineering by:
Surveyring by:
SCALE
DRAWN
JOB. NO.
PERC RATE <2 MIN/IN. "B&C" HORIZONS
Engineering Works, Inc.
JC Engineering, Inc.
N.T.S.
P.T.M.
163-18
DESIGN FLOW PROVIDED: 0.74 GPD/SF(480.0 SF)
= 355.2 GPD
STANDING G.W. 0 97", (EL.=91.3)
INDEX WELL, MIW-29, ZONE A,WATER LEVEL=5.7, ADJUSTMENT=0.0', APRIL 2018
12 West Crossfield Road
Forestdole, MA 02644
2854 Cranberry Hwy.
E.Woreham, MA 02538
DATE
CHECKED
SHEET N0.
(508) 477-5313
(508) 273-0377
5/26/18
P.T.M.
2 Of 2