Loading...
HomeMy WebLinkAboutEngineered Plan - Rev. 2018LEGEND -- 99- EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. -[99]- PROPOSED CONTOUR 198.41 PROPOSED SPOT EL. TH1 YARMOLITHPORT t� TEST HOLE 2� SLOPE OF GROUND 20 UTILITY POLE FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING I , . ._ FIRST FLOOR EL. 10.9 SYSTEM PROFILE MARK CORNERS OF (NOT TO SCALE) LEACHING FIELD W/ PROVIDE MIN. 20" DIAM. WATERTIGHT REBAR SET 4" BELOW ACCESS COVERS TO WITHIN 6" OF FIN. GRADE GRADE FINISHED GRADE - FILTER FABRIC 4" LOAM & SEED TOP 7.31' 9 7MINIMUM 75' OF COVER OVER PRECAST 1 z 9 0 *9.0'± INV. #2 ;,: PRECAST H-10 RISERS (TYP.) 2'0 4"OSCH40 PVC 6" MIN. SUMP PIPES LEVEL 1ST 2' '�'�`'' 12" MIN. INT. DIM. INV. #1 :1 *8.8'± 10" 2500 GAL H-10 14" ' INV. #3� ' 7.51' TEE SEPTIC TANK TEE 7 26' ; 6.98; (LAUNDRY) *7.85'± " 000000000000 WATERTEST D'BOX GAS BAFFLE °Oe���o°�°o° FOR LEVELNESS 4' LIQ. LEVEL (ACME OR EQUAL) 7.22' 7'05' ...3..� ' :. .:....: •• ...' :. : .. �i� ... •.. •. . o00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Oft •o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 O 000 O O O O O 0000000000000 O O O O O O 000 0O no000 h00070 70700000(' O �`O 000o„O„OOo00. 6" CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 [2]) (-i--97. SLOPE) 30' ( 1 % SLOPE) (1 SLOPE) �4 PE 4' PERFORATED PVC 5' O.C. S=0.005 0 0 3/4--l-1/2" DOUBLE WASHED 0 8" STONE LEACHING FIELD 0 LEVEL BOTTOM o 36.0' PROVIDE INSPECTION PORTS TO WITHIN 3" OF FINISH GRADE T6.8' OR CONNECT TERAL ENDS 6 -DEPTH MIN BELOW INV. 6.3' 4.0'** ADJUSTED GROUNDWATER 2.3' ( u5l J FOUNDATION 24' SEPTIC TANK 4 D' BOX 9' LEACHING FACILITY 31' #1 1 (--L-% SLOPE) 4"OSCH40 PVC PIPES LEVEL 1ST 2' *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL 6" MIN. SUMP UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS 12" MIN. INT. DIM. MATCH EXISTING PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM INVERTS IN TO =77 STD'BOX EXISTING LEACHING ELNESSPITS BOUYANCY CALCULATIONS H-10 2,500 GAL. SEPTIC TANK WEIGHS 31,000, LBS 2.12 x 11.0 x 6.0 X 62.4 = 8,731 LBS UP (OK) (--L-% SLOPE) (-a-% SLOPE) EXISTING SEPTIC TANK LEACHING 8' D' BOX 17-22" #2 PITS SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 10 BEDROOMS @ 110 GPD = 1100 GPD USE A 1100 GPD DESIGN FLOW SEPTIC TANK: 1100 GPD (2) = 2200 USE A 2,500 GAL. SEPTIC TANK LEACHING: EXISTING 5 BEDROOM SYSTEM TO REMAIN NEW 5 BEDROOM LEACHING PROPOSED FOR A TOTAL OF 10 BEDROOMS 550 GPD / (.74) = 744 SF REQUIRED 21'X36'=756 SF OK 756 SF X .74 = 559 GPD OK USE A 21' X 36' PIPE AND STONE LEACHING FIELD VARIANCES REQUESTED UNDER TITLE 5 AND YARMOUTH HEALTH REGULATIONS: 1 h: REDUCTION IN GROUNDWATER SEPARATION, 5' TO 4' (lb): REDUCTION IN SETBACK, SAS TO FOUNDATION (20' TO 14.3') DICE #08-184 { NOTES 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H -LQ 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED BENEATH AND 5' AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. BED ROOM PORCH I BATH BARN a KITCHEN DINING I LIVING ROOM ROOM FIRST FLOOR BED ROOM BED BED. ROOM ROOM BED Q BED ROOM m ROOM BED BED SITTING AREA HALLWAY ROOM ROOM PORCH �FMFAICLLC BED BEDSECOND FLOOR ROOM ROOM FLOOR PLAN NOT TO SCALE NOTE: NO BEDROOMSON THE FIRST FLOOR OF EXISTING DWELLING LOCUS MAP SCALE 1"=2000'± ASSESSORS MAP 42 PARCEL 147 LOCUS IS WITHIN FEMA FLOOD ZONE AE (100 YEAR FLOOD ZONE -EL. 11) AS SHOWN ON COMMUNITY PANEL #25001CO589J DATED 7/16/2014 TEST HOLE LOGS ENGINEER: DANIEL E. GONSALVES, SE #13587 WITNESS: AMY VON HONE, RS DATE: 12/6/17 PERC. RATE _ < 2 MIN/INCH CLASS 1 SOILS Q2 ELEV. OSP 9.2' A LS 12" 1OYR 4/2 B LS 1OYR 5/6 24" 7.2' PERC C MS G -W ADJ. DATA: WELL: MIW 29 2.3' ADJUSTED ZONE: A 1OYR 7/4 GROUNDWATER ADJUSTMENT: 1.6' fermi( valid. for REPAIR OF SE ll"FIC SYS'FFM1 132 -1.8, ()N[,V, due to State and Focal septic variances. tioard.of`Ilealth. review and .approval is required for :any future additions/renovations/alterations 'to GROUNDWATER ENCOUNTERED @ 102" sewage faci4ities incl/or structures/dwelling. EL. 0.7 Yarmouth He4'1th I>epartment .2. ��X Name Date I � P, Ilil I IIT LAN I I I OF 127 RIVER STREET SOUTH YARMOUTH, MA PREPARED FOR FRED CHURCHILL DATE: FEBRUARY 12, 2018 land REV: MARCH 21, 2018 (ADD INV.) Scale: 1 "= Q, DATE RRECEI EL YARMOLITHPORT t� or c° 0 10 20 30 40 50 FEET p� °W St. HEALTH DEPT. Rote ti o L OCUS � c r fax 508-362-9880 I Q a doWn cape est Dennis Be a civil engineers 0 a � � z �y geoch J' r.8oss River s outround S Nantucket LOCUS MAP SCALE 1"=2000'± ASSESSORS MAP 42 PARCEL 147 LOCUS IS WITHIN FEMA FLOOD ZONE AE (100 YEAR FLOOD ZONE -EL. 11) AS SHOWN ON COMMUNITY PANEL #25001CO589J DATED 7/16/2014 TEST HOLE LOGS ENGINEER: DANIEL E. GONSALVES, SE #13587 WITNESS: AMY VON HONE, RS DATE: 12/6/17 PERC. RATE _ < 2 MIN/INCH CLASS 1 SOILS Q2 ELEV. OSP 9.2' A LS 12" 1OYR 4/2 B LS 1OYR 5/6 24" 7.2' PERC C MS G -W ADJ. DATA: WELL: MIW 29 2.3' ADJUSTED ZONE: A 1OYR 7/4 GROUNDWATER ADJUSTMENT: 1.6' fermi( valid. for REPAIR OF SE ll"FIC SYS'FFM1 132 -1.8, ()N[,V, due to State and Focal septic variances. tioard.of`Ilealth. review and .approval is required for :any future additions/renovations/alterations 'to GROUNDWATER ENCOUNTERED @ 102" sewage faci4ities incl/or structures/dwelling. EL. 0.7 Yarmouth He4'1th I>epartment .2. ��X Name Date I � P, Ilil I IIT LAN I I I OF 127 RIVER STREET SOUTH YARMOUTH, MA PREPARED FOR FRED CHURCHILL DATE: FEBRUARY 12, 2018 land REV: MARCH 21, 2018 (ADD INV.) Scale: 1 "= 20' DATE RRECEI EL YARMOLITHPORT t� MAR 2 9 2010 0 10 20 30 40 50 FEET HEALTH DEPT. Off 508-362-4541 r fax 508-362-9880 I downcope.com @ doWn cape enfiri4eerift', inC. civil engineers 07-001 CHURCHILL 2017-1.DWG SsTt-_,�'TNS, --�. land surveyors 939 Main Street ( Rte 6A) DATE DANIEL A. OJALA, P.E., P.L.S. YARMOLITHPORT MA 02675 07-001 CHURCHILL 2017-1.DWG